Electromedical Device And Expert System for Early Detection of Hyperemesis Gravidarum

Jurnal Nasional Teknik Elektro (2023) · hlm. 30–36

DOI
10.25077/jnte.v12n3.1130.2023
ISSN
2302-2949, 2407-7267
Terbit
2023-11-30
Penerbit
Andalas University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

Hyperemesis Gravidarum (HG) is a pregnancy complication that is often overlooked as it is typically considered normal. If HG is not properly treated, nutrition will not be fulfilled which can negatively affect maternal and fetal health and even maternal and fetal death. The exact cause of HG is not identified, so there are no effective preventive methods. However early detection can help for prompt and appropriate treatment. Therefore, a monitoring system for pregnancy conditions was designed for HG early detection. This system employs the MPX5050 DP pressure sensor for measuring blood pressure, the MAX30100 for assessing maternal heart rate and oxygen saturation, the MAX4466 sensor for monitoring fetal heart rate, and an expert system using the certainty factor method to diagnose the probability of hyperemesis gravidarum. The expert system achieves an accuracy of 93.33%. In comparison to the aneroid sphygmomanometer, the designed sphygmomanometer reveals a mean difference of 3.5 mmHg for diastolic pressure, with a standard deviation below 8 mmHg for both systolic and diastolic pressures. The measurement of heart rate and oxygen saturation has a deviation of 1.8 % and 1.02 % respectively. These deviations align with the standards specified by the Ministry of Health for medical devices. For the fetal heart rate, the mean deviation is 3.4 bpm, and the measurement error is 2.38%. Thus, this system can be utilized to monitor pregnancy conditions, enabling the early detection of hyperemesis gravidarum

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 98 tautan kepenulisan bersama · 30 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • University of Bengkulu
  • Universitas PGRI Sumatera Barat
  • Universitas Ekasakti
  • Sumatera Institute of Technology
  • Politeknik Negeri Padang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mumuh MuharamAndalas University3
Noris Fredi YuliantoAfiliasi tidak diketahui2
Wayu Diafridho AAndalas University2
Aidil DanasUniversitas Ekasakti2
Hendy SantosaUniversity of Bengkulu2
Junas HaidiUniversity of Bengkulu2
Firdaus FirdausPoliteknik Negeri Padang2
Rudy FernandezAndalas University2
Nova ResfitaSumatera Institute of Technology1
Rahmadi KurniaAndalas University1
Syafii SyafiiAndalas University1
Muhardika MuhardikaAndalas University1
Mahendri SaputraAndalas University1
Refdinal NazirAndalas University1
Hamdi RezaAndalas University1
Indra AgustianUniversity of Bengkulu1
Nikki Aldi MassardiUniversity of Bengkulu1
M. AlbbiUniversity of Bengkulu1
Afriyastuti HerawatiUniversity of Bengkulu1
Valdesio AnugrahAndalas University1
Adry FebriandaAndalas University1
Aulia AuliaAndalas University1
Aprila Tiy PaskalinaAndalas University1
Amirul LuthfiAndalas University1
Syukri YunusAndalas University1
Putri NidyaAndalas University1
MazuesAndalas University1
. .Afiliasi tidak diketahui1
Novizon NovizonAndalas University1
N RiskaAndalas University1
Alrino Rizki RamadhanAndalas University1
Doohan HalimanAndalas University1
Syafi’iAndalas University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Electromedical Device And Expert System for Early Detection of Hyperemesis Gravidarum</dc:title><dc:creator>Fitrilina Fitrilina</dc:creator><dc:creator>Ganesha</dc:creator><dc:creator>Yanolanda Suzantry Handayani</dc:creator><dc:creator>Alex Surapati</dc:creator><dc:creator>Rahayu Trisetyowati Untari</dc:creator><dc:creator>Heru Dibyo Laksono</dc:creator><dc:creator>Melda Latif</dc:creator><dc:subject>hyperemesis gravidarum</dc:subject><dc:subject>early detection</dc:subject><dc:subject>pregnancy monitoring</dc:subject><dc:subject>blood pressure measurement</dc:subject><dc:subject>fetal heart rate monitoring</dc:subject><dc:subject>maternal heart rate</dc:subject><dc:subject>oxygen saturation</dc:subject><dc:subject>expert systems</dc:subject><dc:subject>certainty factor</dc:subject><dc:subject>medical device design</dc:subject><dc:subject>sensor-based monitoring</dc:subject><dc:description xml:lang="en">Hyperemesis Gravidarum (HG) is a pregnancy complication that is often overlooked as it is typically considered normal. If HG is not properly treated, nutrition will not be fulfilled which can negatively affect maternal and fetal health and even maternal and fetal death. The exact cause of HG is not identified, so there are no effective preventive methods. However early detection can help for prompt and appropriate treatment. Therefore, a monitoring system for pregnancy conditions was designed for HG early detection. This system employs the MPX5050 DP pressure sensor for measuring blood pressure, the MAX30100 for assessing maternal heart rate and oxygen saturation, the MAX4466 sensor for monitoring fetal heart rate, and an expert system using the certainty factor method to diagnose the probability of hyperemesis gravidarum. The expert system achieves an accuracy of 93.33%. In comparison to the aneroid sphygmomanometer, the designed sphygmomanometer reveals a mean difference of 3.5 mmHg for diastolic pressure, with a standard deviation below 8 mmHg for both systolic and diastolic pressures. The measurement of heart rate and oxygen saturation has a deviation of 1.8 % and 1.02 % respectively. These deviations align with the standards specified by the Ministry of Health for medical devices. For the fetal heart rate, the mean deviation is 3.4 bpm, and the measurement error is 2.38%. Thus, this system can be utilized to monitor pregnancy conditions, enabling the early detection of hyperemesis gravidarum</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2023-11-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>http://dx.doi.org/10.25077/jnte.v12n3.1130.2023</dc:identifier><dc:identifier>10.25077/jnte.v12n3.1130.2023</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; (2023); 30-36</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>en</dc:language><dc:relation>https://jnte.ft.unand.ac.id/index.php/jnte/article/download/1130/501</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>