Study on Shear Behavior of Concrete-polymer Cement Mortar at Elevated Temperature
Civil Engineering Dimension · Vol. 18 No. 2 (2016) · hlm. 93–102
ISSN 1410-9530, 1979-570X
Terbit 2016-10-01
Penerbit Petra Christian University
Bahasa en
Abstrak
In this experimental and analytical work, interfacial shear strengths were evaluated at material and member level. Bi-surface shear strength was performed at material level and three-point bending test was conducted at member level. Beams were strengthened by adding steel reinforcement at soffit level and covered by spraying polymer cement mortar (PCM). After curing, strengthened RC beams were exposed to 60 ℃ for 24 hours and tested in three point loading test. Flexural capacity, load deflection relationship and failure modes were observed and compared with the strengthened beams tested at 20 ℃. Reduction in flexural capacity was observed with temperature, failure mode was also shifted from flexural mode to debonding mode of failure at elevated temperature. Ultimate shear load and failure modes were predicted by truss analogy approach. Debonding model was proposed by incorporating bi-surface interfacial shear strength, close agreement were observed between experimental and predicted values.
Jaringan kolaborasi para penulis
5 penulis ·
6 tautan kepenulisan bersama
· 3 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Hokkaido University University of Engineering and Technology Lahore Zhejiang University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765058718, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Study on Shear Behavior of Concrete-polymer Cement Mortar at Elevated Temperature</dc:title><dc:creator>Khuram Rashid</dc:creator><dc:creator>Tamon Ueda</dc:creator><dc:creator>Dawei Zhang</dc:creator><dc:subject>polymer-modified mortar</dc:subject><dc:subject>high temperature</dc:subject><dc:subject>interfacial shear strength</dc:subject><dc:subject>steel-concrete bond</dc:subject><dc:subject>flexural strengthening</dc:subject><dc:subject>reinforced concrete beams</dc:subject><dc:subject>three-point bending</dc:subject><dc:subject>debonding failure mode</dc:subject><dc:subject>truss analogy</dc:subject><dc:subject>failure mode prediction</dc:subject><dc:subject>fire resistance</dc:subject><dc:description xml:lang="en">In this experimental and analytical work, interfacial shear strengths were evaluated at material and member level. Bi-surface shear strength was performed at material level and three-point bending test was conducted at member level. Beams were strengthened by adding steel reinforcement at soffit level and covered by spraying polymer cement mortar (PCM). After curing, strengthened RC beams were exposed to 60 ℃ for 24 hours and tested in three point loading test. Flexural capacity, load deflection relationship and failure modes were observed and compared with the strengthened beams tested at 20 ℃. Reduction in flexural capacity was observed with temperature, failure mode was also shifted from flexural mode to debonding mode of failure at elevated temperature. Ultimate shear load and failure modes were predicted by truss analogy approach. Debonding model was proposed by incorporating bi-surface interfacial shear strength, close agreement were observed between experimental and predicted values.</dc:description><dc:publisher>Petra Christian University</dc:publisher><dc:date>2016-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.9744/ced.18.2.93-102</dc:identifier><dc:identifier>10.9744/ced.18.2.93-102</dc:identifier><dc:source>Civil Engineering Dimension; Vol 18 No 2 (2016); 93-102</dc:source><dc:source>1410-9530</dc:source><dc:source>1979-570X</dc:source><dc:language>en</dc:language><dc:relation>http://ced.petra.ac.id/index.php/civ/article/view/19712/18999</dc:relation><dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
14 sitasi
Crossref
Terindeks
lewat DOI
7 sitasi
Jumlah menurut tiap indeks pada 20 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, datacite, doaj.
Sitasi artikel ini
APA 7
Rashid, K., Ueda, T., & Zhang, D. (2016). Study on Shear Behavior of Concrete-polymer Cement Mortar at Elevated Temperature. Civil Engineering Dimension, 18(2), 93–102. https://doi.org/10.9744/ced.18.2.93-102
Salin
IEEE
K. Rashid, T. Ueda, and D. Zhang, “Study on Shear Behavior of Concrete-polymer Cement Mortar at Elevated Temperature,” Civil Engineering Dimension, vol. 18, no. 2, pp. 93–102, 2016, doi: 10.9744/ced.18.2.93-102.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.