DEVELOPMENT OF NON-DESTRUCTIVE MONITORING SYSTEM FOR CHLORIDE PENETRATION INTO REINFORCED CONCRETE STRUCTURES

Civil Engineering Dimension · Vol. 8 No. 2 (2006) · hlm. 99–105

ISSN
1410-9530, 1979-570X
Terbit
2006-07-24
Penerbit
Petra Christian University
Bahasa
en
Lisensi
creativecommons.org/licenses/by/4.0/

Abstrak

Reinforced concrete structures in marine environment are subjected to chloride penetration, which significantly degrades the structural performance due to the occurrence of corrosion in the steel reinforcement. The performance degradation of the structures would reduce the intended service life and caused higher maintenance and repair cost. Therefore, system to monitor chloride penetration into reinforced concrete before the starting corrosion of reinforcement is indispensable. An embedded probe system to detect chloride penetration into concrete was developed in Japan. This probe consists of a cementitious material body and some number of wires as sensors, which are set in the shallow ditches around the probe body. The system detect the chloride penetration by monitoring the initiation time of wire corrosion, it also has the advantages of continuous monitoring and early warning on the onset of corrosion in the reinforcement. However, the probe had not yet had high sensitivity for detecting critical chloride content in concrete. Therefore to increase its sensitivity, four types of improvements, namely partial coating of the wires, waterproofing on the probe body, filling the ditches with porous material and supplying small current on the wires were evaluated in this study. From the experimental result, it was observed that supplying small current and partial coating of the wires could improve the sensitivity of the probe significantly, while waterproofing treatment on the probe body and filling the ditches did not have significant contribution.

Kata kunci

Jaringan kolaborasi para penulis

28 penulis · 83 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Petra Christian University
  • National University of Malaysia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Djwantoro HardjitoPetra Christian University6
Nurdin Bakri Nurdin BakriAfiliasi tidak diketahui1
Zulkefly Abdul KarimNational University of Malaysia1
Norain Mod AsriAfiliasi tidak diketahui1
Azrina Al-Hadi AbdullahAfiliasi tidak diketahui1
Zetty Zahureen Mohd YusoffAfiliasi tidak diketahui1
Franky BudimanPetra Christian University1
Jimmy ChandraPetra Christian University1
Alvin HalimPetra Christian University1
Pamuda PudjisuryadiPetra Christian University1
Vindy SatryaPetra Christian University1
Florentcia HartonoPetra Christian University1
Steven TanuwijayaPetra Christian University1
Kevin Adrian WijayaPetra Christian University1
Agie VianthiPetra Christian University1
Hendra Surya WibawaPetra Christian University1
Oswyn K. WattimenaPetra Christian University1
Stacia Dwi ShenjayaPetra Christian University1
Maria LupitaPetra Christian University1
Samuel SantosaPetra Christian University1
David WiyonoPetra Christian University1
Edwin MihardjaPetra Christian University1
Elbert G. RiadyPetra Christian University1
Samuel V. SuhendroPetra Christian University1
Tri Eddy SusantoAfiliasi tidak diketahui1
Rizky T. AkbarAfiliasi tidak diketahui1
Bangkit Tegar T. AnuragaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765058718, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">DEVELOPMENT OF NON-DESTRUCTIVE MONITORING SYSTEM FOR CHLORIDE PENETRATION INTO REINFORCED CONCRETE STRUCTURES</dc:title><dc:creator>Antoni Antoni</dc:creator><dc:subject>chloride penetration</dc:subject><dc:subject>reinforced concrete</dc:subject><dc:subject>reinforcement corrosion</dc:subject><dc:subject>non-destructive monitoring</dc:subject><dc:subject>marine environment</dc:subject><dc:subject>corrosion initiation</dc:subject><dc:subject>probe sensitivity</dc:subject><dc:subject>wire coating</dc:subject><dc:subject>waterproofing</dc:subject><dc:subject>service life</dc:subject><dc:description xml:lang="en">Reinforced concrete structures in marine environment are subjected to chloride penetration, which significantly degrades the structural performance due to the occurrence of corrosion in the steel reinforcement. The performance degradation of the structures would reduce the intended service life and caused higher maintenance and repair cost. Therefore, system to monitor chloride penetration into reinforced concrete before the starting corrosion of reinforcement is indispensable. An embedded probe system to detect chloride penetration into concrete was developed in Japan. This probe consists of a cementitious material body and some number of wires as sensors, which are set in the shallow ditches around the probe body. The system detect the chloride penetration by monitoring the initiation time of wire corrosion, it also has the advantages of continuous monitoring and early warning on the onset of corrosion in the reinforcement. However, the probe had not yet had high sensitivity for detecting critical chloride content in concrete. Therefore to increase its sensitivity, four types of improvements, namely partial coating of the wires, waterproofing on the probe body, filling the ditches with porous material and supplying small current on the wires were evaluated in this study. From the experimental result, it was observed that supplying small current and partial coating of the wires could improve the sensitivity of the probe significantly, while waterproofing treatment on the probe body and filling the ditches did not have significant contribution.</dc:description><dc:publisher>Petra Christian University</dc:publisher><dc:date>2006-07-24</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://203.189.121.7/~puslit2_ejournal/ejournal/index.php/civ/article/download/16466/16458</dc:identifier><dc:source>Civil Engineering Dimension; Vol 8 No 2 (2006); 99-105</dc:source><dc:source>1410-9530</dc:source><dc:source>1979-570X</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights></oai_dc:dc>