Experimental Study of Two-way Half Slab Precast Concrete using Rextangular Rigid Connection

Civil Engineering Dimension · Vol. 26 No. 1 (2024) · hlm. 63–70

DOI
10.9744/ced.26.1.63-70
ISSN
1410-9530, 1979-570X
Terbit
2024-03-04
Penerbit
Petra Christian University
Bahasa
en
Lisensi
creativecommons.org/licenses/by/4.0/

Abstrak

A half-slab precast concrete (HSPC) system with precast bottom layers and in-situ cast top layers has been widely applied in various constructions. It generally behaves as a one-way slab due to the absence of positive-flexural reinforcements in the perpendicular direction to the precast component. However, in some cases, the HSPC was also applied in a two-way slab system. Consequently, a particular design and treatment in the connection between precast members was required, so that the bending moment in two orthogonal directions could be accommodated. In the present study, an innovative rectangular rigid connection (RRC) in a two-way HSPC system was investigated through an experimental test. It was found that the RRC-HSPC presented only a 9.13% reduction of the load at the crack, a 16.44% reduction of the ultimate load, and a 6.06% increase of the deflection at the crack when compared to the monolithic one.

Kata kunci

Jaringan kolaborasi para penulis

20 penulis · 51 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Sepuluh Nopember
  • Heriot-Watt University
  • Institut Teknologi Adhi Tama Surabaya
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Asdam TambusayHeriot-Watt University5
Benny SuryantoHeriot-Watt University5
W. DonHeriot-Watt University1
Karen ChongHeriot-Watt University1
Fillbert Hanselly NjokoInstitut Teknologi Sepuluh Nopember1
Andrew JamiesonHeriot-Watt University1
Dedy Dwi PrastyoInstitut Teknologi Sepuluh Nopember1
Bangun Muljo SukojoInstitut Teknologi Sepuluh Nopember1
Nadjadji AnwarInstitut Teknologi Sepuluh Nopember1
Nur Azizah AffandyInstitut Teknologi Sepuluh Nopember1
Mahendra Andiek MaulanaInstitut Teknologi Sepuluh Nopember1
Wasis WardoyoInstitut Teknologi Sepuluh Nopember1
Tavio TavioInstitut Teknologi Sepuluh Nopember1
Heppy KristijantoInstitut Teknologi Sepuluh Nopember1
Dita Kamarul FitriyahInstitut Teknologi Adhi Tama Surabaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765058718, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Experimental Study of Two-way Half Slab Precast Concrete using Rextangular Rigid Connection</dc:title><dc:creator>Djoko Windu P. Irawan</dc:creator><dc:creator>Ahmad Basshofi Habieb</dc:creator><dc:creator>Data Iranata</dc:creator><dc:creator>Priyo Suprobo</dc:creator><dc:creator>I Gusti Putu Raka</dc:creator><dc:subject>two-way slabs</dc:subject><dc:subject>cracking load</dc:subject><dc:subject>ultimate load</dc:subject><dc:subject>deflection</dc:subject><dc:description xml:lang="en">A half-slab precast concrete (HSPC) system with precast bottom layers and in-situ cast top layers has been widely applied in various constructions. It generally behaves as a one-way slab due to the absence of positive-flexural reinforcements in the perpendicular direction to the precast component. However, in some cases, the HSPC was also applied in a two-way slab system. Consequently, a particular design and treatment in the connection between precast members was required, so that the bending moment in two orthogonal directions could be accommodated. In the present study, an innovative rectangular rigid connection (RRC) in a two-way HSPC system was investigated through an experimental test. It was found that the RRC-HSPC presented only a 9.13% reduction of the load at the crack, a 16.44% reduction of the ultimate load, and a 6.06% increase of the deflection at the crack when compared to the monolithic one.</dc:description><dc:publisher>Petra Christian University</dc:publisher><dc:date>2024-03-04</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>http://dx.doi.org/10.9744/ced.26.1.63-70</dc:identifier><dc:identifier>10.9744/ced.26.1.63-70</dc:identifier><dc:source>Civil Engineering Dimension; Vol 26 No 1 (2024); 63-70</dc:source><dc:source>1410-9530</dc:source><dc:source>1979-570X</dc:source><dc:language>en</dc:language><dc:relation>https://ced.petra.ac.id/index.php/civ/article/download/26962/21075</dc:relation><dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights></oai_dc:dc>