COMPARISON OF GLOBAL WARMING POTENTIAL-IMPACT ON THE HANDLING OF THE HAZARDOUS-SLUDGE FROM THE CENTRALIZED INDUSTRIAL-WASTEWATER TREATMENT PLANT

INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY (2019) · hlm. 84–102

DOI
10.25105/urbanenvirotech.v3i1.5530
ISSN
2579-9150, 2579-9207
Terbit
2019-10-30
Penerbit
Universitas Trisakti
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Aim: This study aimed to compare the secured landfill method and thermally sludge treatment through gasification, in order to determine their environmental impacts. Methodology and Results: The gate-to-gate LCA method was the implementation approach used to determine the, limits and assumptions to the actual condition. The experimental, theoretical mass balance calculation and secondary data of previous researches were used to carry out this study, with open-source openLCA software. In addition, the LCA was made up of four phases which include goal and scope definition, inventory analysis, impact assessment, and data interpretation. The simulation showed that the implementation of the thermal gasification process reduced the emission released to the atmosphere by lowering the hazardous sludge volume which is directly transported to the secured landfill. Conclusion, significance and impact study: Several assumptions and adjustments were made to the simulation results using the openLCA software, in the determined scope of study. Therefore, in conclusion, the thermal (gasification) treatment of hazardous sludge is further studied in connection with its implementation at the treatment plant. This was indicated by the acquisition of global warming potential impact category of 673 kg CO2 eq for direct disposal to secured landfill, which reduced to 424 kg CO2 eq during the implementation of thermal treatment. Conversely, there is a reduction in magnitude of impact by 37%.

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 25 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • President University
  • IPB University
  • University of Auckland
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Yunita IsmailPresident University3
Filson Maratur SidjabatPresident University3
Erliza NoorIPB University1
Bambang PramudyaIPB University1
Sekolah Pascasarjana Institut Pertanian Bogor, Kampus IPB Darmaga, Bogor 16680 Program Studi Pengelolaan Sumber Daya Alam dan LingkunganIPB University1
Fakultas Teknologi Pertanian, Institut Pertanian Bogor, Kampus IPB Darmaga, Bogor 16680 Departemen Teknik Mesin dan BiosistemAfiliasi tidak diketahui1
Fakultas Teknologi Pertanian, Institut Pertanian Bogor, Kampus IPB Darmaga, Bogor 16680 Departemen Teknologi Industri PertanianAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210216775, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">COMPARISON OF GLOBAL WARMING POTENTIAL-IMPACT ON THE HANDLING OF THE HAZARDOUS-SLUDGE FROM THE CENTRALIZED INDUSTRIAL-WASTEWATER TREATMENT PLANT</dc:title><dc:creator>Rijal Hakiki</dc:creator><dc:creator>Maryani Paramita Astuti</dc:creator><dc:creator>Temmy Wikaningrum</dc:creator><dc:subject>global warming potential</dc:subject><dc:subject>industrial wastewater treatment plant</dc:subject><dc:subject>thermal gasification</dc:subject><dc:subject>greenhouse gas emissions</dc:subject><dc:subject>life cycle assessment</dc:subject><dc:subject>sludge treatment</dc:subject><dc:description xml:lang="en">Aim: This study aimed to compare the secured landfill method and thermally sludge treatment through gasification, in order to determine their environmental impacts. Methodology and Results: The gate-to-gate LCA method was the implementation approach used to determine the, limits and assumptions to the actual condition. The experimental, theoretical mass balance calculation and secondary data of previous researches were used to carry out this study, with open-source openLCA software. In addition, the LCA was made up of four phases which include goal and scope definition, inventory analysis, impact assessment, and data interpretation. The simulation showed that the implementation of the thermal gasification process reduced the emission released to the atmosphere by lowering the hazardous sludge volume which is directly transported to the secured landfill. Conclusion, significance and impact study: Several assumptions and adjustments were made to the simulation results using the openLCA software, in the determined scope of study. Therefore, in conclusion, the thermal (gasification) treatment of hazardous sludge is further studied in connection with its implementation at the treatment plant. This was indicated by the acquisition of global warming potential impact category of 673 kg CO2 eq for direct disposal to secured landfill, which reduced to 424 kg CO2 eq during the implementation of thermal treatment. Conversely, there is a reduction in magnitude of impact by 37%.</dc:description><dc:publisher>Universitas Trisakti</dc:publisher><dc:date>2019-10-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.25105/urbanenvirotech.v3i1.5530</dc:identifier><dc:identifier>10.25105/urbanenvirotech.v3i1.5530</dc:identifier><dc:source>INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY; (2019); 84-102</dc:source><dc:source>2579-9150</dc:source><dc:source>2579-9207</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>