Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

COMBINATION OF FeCl3 AND Fe3O4 AS A MAGNETIC COAGULANT FOR CONGO RED REMOVAL

INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY (2025) · hlm. 99–115

DOI
10.25105/urbanenvirotech.v8i1.22575
ISSN
2579-9150, 2579-9207
Terbit
2025-04-24
Penerbit
Universitas Trisakti
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

Water pollution remains a critical environmental issue, necessitating efficient treatment technologies, among which, coagulation is still widely applied due to its effectiveness in removing colloidal particles and organic pollutants. Inorganic coagulants remain a preferred coagulant despite drawbacks such as excessive sludge formation and long settling times. To address these limitations, the integration of magnetic nanoparticles to form magnetic coagulants has emerged as a promising strategy. Aims: This study was aimed to investigate the effectiveness of the FeCl3 - magnetite (Fe3O4) combination as a magnetic coagulant for the removal of Congo red from synthetic wastewater. Methodology and results: The influence of key parameters, including pH (3-8), coagulant dose (4-44 mL/L), magnetite dose (0-200 mg/L), and initial dye concentration (50-100 mg/L), was systematically evaluated. Coagulation experiment was done by using a standard jar test apparatus. The settling kinetic was evaluated by using pseudo-first and second-order kinetic model. Conclusion, significance and impact study: It was found that pH 6, coagulant dose of 20 mL/L FeCl3 0.5 M, and magnetite dose of 150 mg/L gave the best coagulation efficiency with 95% removal of 50 mg/L Congo red wastewater. Furthermore, the settling kinetics showed a good suitability with non-linear pseudo-second order-model kinetics. Results demonstrated that FeCl3-Fe3O4 as a magnetic coagulant significantly improved floc formation, settling efficiency, and overall pollutant removal.

Kata kunci

Jaringan kolaborasi para penulis

11 penulis · 24 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Parahyangan Catholic University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Joshua AlexanderParahyangan Catholic University3
Novitri DaulayParahyangan Catholic University1
Arenst Andreas ArieParahyangan Catholic University1
Illona NathaniaParahyangan Catholic University1
Henky MuljanaParahyangan Catholic University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210216775, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">COMBINATION OF FeCl3 AND Fe3O4 AS A MAGNETIC COAGULANT FOR CONGO RED REMOVAL</dc:title><dc:creator>Asaf Kleopas Sugih</dc:creator><dc:creator>Muhammad A Deiza</dc:creator><dc:creator>Safri F Nurmawan</dc:creator><dc:creator>Susiana Prasetyo</dc:creator><dc:creator>Daniel Tan</dc:creator><dc:creator>Hans Kristianto</dc:creator><dc:subject>Congo red removal</dc:subject><dc:subject>ferric chloride</dc:subject><dc:subject>magnetite</dc:subject><dc:subject>Fe3O4 nanoparticles</dc:subject><dc:subject>dye wastewater treatment</dc:subject><dc:subject>coagulation</dc:subject><dc:subject>pseudo-second-order kinetics</dc:subject><dc:subject>floc formation</dc:subject><dc:subject>pH effect</dc:subject><dc:subject>coagulant dosage optimization</dc:subject><dc:description xml:lang="en">Water pollution remains a critical environmental issue, necessitating efficient treatment technologies, among which, coagulation is still widely applied due to its effectiveness in removing colloidal particles and organic pollutants. Inorganic coagulants remain a preferred coagulant despite drawbacks such as excessive sludge formation and long settling times. To address these limitations, the integration of magnetic nanoparticles to form magnetic coagulants has emerged as a promising strategy. Aims: This study was aimed to investigate the effectiveness of the FeCl3 - magnetite (Fe3O4) combination as a magnetic coagulant for the removal of Congo red from synthetic wastewater. Methodology and results: The influence of key parameters, including pH (3-8), coagulant dose (4-44 mL/L), magnetite dose (0-200 mg/L), and initial dye concentration (50-100 mg/L), was systematically evaluated. Coagulation experiment was done by using a standard jar test apparatus. The settling kinetic was evaluated by using pseudo-first and second-order kinetic model. Conclusion, significance and impact study: It was found that pH 6, coagulant dose of 20 mL/L FeCl3 0.5 M, and magnetite dose of 150 mg/L gave the best coagulation efficiency with 95% removal of 50 mg/L Congo red wastewater. Furthermore, the settling kinetics showed a good suitability with non-linear pseudo-second order-model kinetics. Results demonstrated that FeCl3-Fe3O4 as a magnetic coagulant significantly improved floc formation, settling efficiency, and overall pollutant removal.</dc:description><dc:publisher>Universitas Trisakti</dc:publisher><dc:date>2025-04-24</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.25105/urbanenvirotech.v8i1.22575</dc:identifier><dc:identifier>10.25105/urbanenvirotech.v8i1.22575</dc:identifier><dc:source>INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY; (2025); 99-115</dc:source><dc:source>2579-9150</dc:source><dc:source>2579-9207</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>