Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

RAW WATER QUALITY ANALYSIS TO DISCOVER THE CAUSE OF PIPELINE SCALLING PROBLEM IN PT. X (ICE PRODUCTION COMPANY)

INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY (2021) · hlm. 72–85

DOI
10.25105/urbanenvirotech.v5i1.10748
ISSN
2579-9150, 2579-9207
Terbit
2021-10-19
Penerbit
Universitas Trisakti
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

PT. X is one of the ice companies in which its largest company is located in Bali, more precisely in the Pidada area, North Denpasar. Based on field observations the area is an area that has a calcareous soil structure. The water source of PT. X was extracted from the groundwater. From the field observation, it was found that the pipeline network, that connected the inlet water to water treatment system and ice production units, was severely covered by faint white scale. In order to discover the origin of this scale, water quality testing need to be carried out. From the results, it was found that the total hardness in the inlet water, taken from the groundwater tap, was 162.85 mg/l with calcium concentration of 2.15 mg/l and iron 3.83 mg/l. Water quality testing was also carried out in the water treatment unit consisting of resin softener where the total hardness surprisingly increased into 279.81 mg/l, calcium concentration was 2.96 mg/l, iron concentration was 0.55 mg/l. Even after being treated in softener resin, the total hardness increased sharply to 483 mg/l, which categorized as extreme hardness. The increase in total hardness indicates that there was a failure in the operation of the water treatment system, even it also contributed to the higher hardness and calcium concentration. This over-year’s treatment failure has been causing accumulation of hardness and calcium concentration in the compartment of both water treatment system and ice production unit that inflicts a higher hardness level in the effluent.

Kata kunci

Jaringan kolaborasi para penulis

32 penulis · 140 tautan kepenulisan bersama · 39 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Udayana University
  • Universitas Pendidikan Ganesha
  • Yamaguchi University
  • Bandung Institute of Technology
  • Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement
  • Trường Đại học Xây dựng Miền Trung
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Gusti Agung Gede BawaUdayana University2
Huy Thanh VoTrường Đại học Xây dựng Miền Trung2
Shingo NakamuraYamaguchi University2
I Gusti Lanang WiratmaUniversitas Pendidikan Ganesha1
I Gede MahardikaUdayana University1
I Nyoman SukartaUniversitas Pendidikan Ganesha1
Iryanti Eka SuprihatinUdayana University1
I Dewa Ketut SastrawidanaUniversitas Pendidikan Ganesha1
Dewa Komang DarmayasaUniversitas Pendidikan Ganesha1
Prayatni SoewondoBandung Institute of Technology1
Daniel Rizal MahendraUdayana University1
Pertiwi Jaya Ni MadeUdayana University1
Ida Ayu Rai WidhiawatiUdayana University1
I Gusti Agung Gede Wiranata BhaskaraUdayana University1
Nyoman Dewi SupriyaniUdayana University1
Debora Sofia Fransiska HutagalungUdayana University1
Masahiko NagaiYamaguchi University1
‪Cokorda Agung Wahyu PurnamasidhiUdayana University1
Ni Made SusilawathiUdayana University1
IDAA WarmadewanthiInstitut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement1
I Komang Hotra AdiputraUdayana University1
Komang Ayu WitariniUdayana University1
I Wayan Arya BiantaraUdayana University1
I Dewa Made SukramaUdayana University1
I Gede Purna WeisnawaUdayana University1
Jerry JerryUdayana University1
Putu Kintan WulandariUdayana University1
Darren JuniorUdayana University1
Dewa Ayu Fony Prema ShantiUdayana University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210216775, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">RAW WATER QUALITY ANALYSIS TO DISCOVER THE CAUSE OF PIPELINE SCALLING PROBLEM IN PT. X (ICE PRODUCTION COMPANY)</dc:title><dc:creator>Kadek Diana Harmayani</dc:creator><dc:creator>Gede Adi Wiguna Sudiartha</dc:creator><dc:creator>I Wayan Budiarsa Suyasa</dc:creator><dc:subject>raw water quality</dc:subject><dc:subject>total hardness</dc:subject><dc:subject>calcium concentration</dc:subject><dc:subject>iron content</dc:subject><dc:subject>ice production</dc:subject><dc:subject>groundwater</dc:subject><dc:subject>calcareous soils</dc:subject><dc:subject>scaling</dc:subject><dc:description xml:lang="en">PT. X is one of the ice companies in which its largest company is located in Bali, more precisely in the Pidada area, North Denpasar. Based on field observations the area is an area that has a calcareous soil structure. The water source of PT. X was extracted from the groundwater. From the field observation, it was found that the pipeline network, that connected the inlet water to water treatment system and ice production units, was severely covered by faint white scale. In order to discover the origin of this scale, water quality testing need to be carried out. From the results, it was found that the total hardness in the inlet water, taken from the groundwater tap, was 162.85 mg/l with calcium concentration of 2.15 mg/l and iron 3.83 mg/l. Water quality testing was also carried out in the water treatment unit consisting of resin softener where the total hardness surprisingly increased into 279.81 mg/l, calcium concentration was 2.96 mg/l, iron concentration was 0.55 mg/l. Even after being treated in softener resin, the total hardness increased sharply to 483 mg/l, which categorized as extreme hardness. The increase in total hardness indicates that there was a failure in the operation of the water treatment system, even it also contributed to the higher hardness and calcium concentration. This over-year’s treatment failure has been causing accumulation of hardness and calcium concentration in the compartment of both water treatment system and ice production unit that inflicts a higher hardness level in the effluent.</dc:description><dc:publisher>Universitas Trisakti</dc:publisher><dc:date>2021-10-19</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.25105/urbanenvirotech.v5i1.10748</dc:identifier><dc:identifier>10.25105/urbanenvirotech.v5i1.10748</dc:identifier><dc:source>INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY; (2021); 72-85</dc:source><dc:source>2579-9150</dc:source><dc:source>2579-9207</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>