Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

ANALYSIS OF RESIDUAL CHLORINE CONCENTRATION IN DISTRIBUTION NETWORK OF DRINKING WATER SUPPLY AT ISTANA DIENG II RESIDENCE OF MALANG, EAST JAVA, INDONESIA

INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY (2022) · hlm. 223–239

DOI
10.25105/urbanenvirotech.v5i3.12463
ISSN
2579-9150, 2579-9207
Terbit
2022-08-13
Penerbit
Universitas Trisakti
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

The drinking water distribution network in Istana Dieng residence is categorized as an isolated network because it does not connect with the other water distribution networks provided by the Malang Water Company (Perusahaan Daerah Air Minum, PDAM). For this reason, the residual chlorine of the isolated distribution network needs to be monitored regularly. Aim: This study aims to observe residual chlorine distribution patterns and investigate the effect of distribution distance, pH, and temperature on residual chlorine concentration in the water distribution network. Methodology and Results: Analytical survey method with a cross-sectional approach was used in this study. The field survey results and the water analysis were inputted into the ArcGIS 10.6 software to generate an Isoconcentration map. Correlation and regression analysis were conducted using SPSS 16.0. Conclusion, significance and impact of study: The results showed that 65% of the residual chlorine concentration in the drinking water distribution network Istana Dieng residence did not meet the quality standard (<0.2 mg/l). Twenty-six sample points showed a value of 0.1 mg/l, which was caused by the pipe's physical condition and the use of wells connected to the PDAM network. There was a significant correlation between distance and residual chlorine concentration. The significant correlation between pH and residual chlorine concentration showed a value of -0.690. The correlation between temperature and residual chlorine concentration was -0.633. It was proven that the lower the residual chlorine concentration, the higher the pH and temperature values in the distribution network.

Kata kunci

Jaringan kolaborasi para penulis

22 penulis · 60 tautan kepenulisan bersama · 15 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Malang
  • University of Brawijaya
  • IPB University
  • Çanakkale Onsekiz Mart Üniversitesi
  • Universiti Teknologi Petronas
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ridwan Muhamad RifaiState University of Malang2
Jenvia Rista PratiwiState University of Malang2
Dwi SiswahyudiState University of Malang1
Ichsan Achmad FauziIPB University1
Nina RachminiwatiAfiliasi tidak diketahui1
Noventia Sekar PratiwiAfiliasi tidak diketahui1
Ghea Pratiwi SantosoState University of Malang1
Hanifa SalsabilaState University of Malang1
Tri Budi PrayogoUniversity of Brawijaya1
Riyanto HaribowoUniversity of Brawijaya1
Farida RahmawatiState University of Malang1
Anna Nisful LailiState University of Malang1
Fahir HassanState University of Malang1
Çiğdem ÖzÇanakkale Onsekiz Mart Üniversitesi1
Syifaa Azkia AzkaState University of Malang1
Rhenata Chriskeowny TelaumbanuaState University of Malang1
Fadiyah Ghina SalsabilaState University of Malang1
Husna Bt TakaijudinUniversiti Teknologi Petronas1
Imam AlfiantoState University of Malang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210216775, pertama di-harvest 21 Nov 2026, terakhir terlihat 21 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">ANALYSIS OF RESIDUAL CHLORINE CONCENTRATION IN DISTRIBUTION NETWORK OF DRINKING WATER SUPPLY AT ISTANA DIENG II RESIDENCE OF MALANG, EAST JAVA, INDONESIA</dc:title><dc:creator>Moh. Zainal Bahrudin</dc:creator><dc:creator>Anie Yulistyorini</dc:creator><dc:creator>Titi Rahayuningsih</dc:creator><dc:subject>residual chlorine</dc:subject><dc:subject>drinking water distribution systems</dc:subject><dc:subject>Malang</dc:subject><dc:subject>distance between distributions</dc:subject><dc:subject>pH</dc:subject><dc:subject>water temperature</dc:subject><dc:subject>chlorine decay</dc:subject><dc:subject>drinking water quality</dc:subject><dc:description xml:lang="en">The drinking water distribution network in Istana Dieng residence is categorized as an isolated network because it does not connect with the other water distribution networks provided by the Malang Water Company (Perusahaan Daerah Air Minum, PDAM). For this reason, the residual chlorine of the isolated distribution network needs to be monitored regularly. Aim: This study aims to observe residual chlorine distribution patterns and investigate the effect of distribution distance, pH, and temperature on residual chlorine concentration in the water distribution network. Methodology and Results: Analytical survey method with a cross-sectional approach was used in this study. The field survey results and the water analysis were inputted into the ArcGIS 10.6 software to generate an Isoconcentration map. Correlation and regression analysis were conducted using SPSS 16.0. Conclusion, significance and impact of study: The results showed that 65% of the residual chlorine concentration in the drinking water distribution network Istana Dieng residence did not meet the quality standard (&lt;0.2 mg/l). Twenty-six sample points showed a value of 0.1 mg/l, which was caused by the pipe's physical condition and the use of wells connected to the PDAM network. There was a significant correlation between distance and residual chlorine concentration. The significant correlation between pH and residual chlorine concentration showed a value of -0.690. The correlation between temperature and residual chlorine concentration was -0.633. It was proven that the lower the residual chlorine concentration, the higher the pH and temperature values in the distribution network.</dc:description><dc:publisher>Universitas Trisakti</dc:publisher><dc:date>2022-08-13</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25105/urbanenvirotech.v5i3.12463</dc:identifier><dc:identifier>10.25105/urbanenvirotech.v5i3.12463</dc:identifier><dc:source>INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY; (2022); 223-239</dc:source><dc:source>2579-9150</dc:source><dc:source>2579-9207</dc:source><dc:language>en</dc:language><dc:relation>https://e-journal.trisakti.ac.id/index.php/urbanenvirotech/article/download/12463/8494</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>