Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Integration of Chromophoric Dissolved Organic Matter Quantification into Water Safety Plans at Urban Conventional Treatment Plants

INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY (2026) · hlm. 473–492

DOI
10.25105/urbanenvirotech.v9i2.24290
ISSN
2579-9150, 2579-9207
Terbit
2026-08-01
Penerbit
Universitas Trisakti
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-nd/4.0/

Abstrak

The presence of chromophoric dissolved organic matter (CDOM) in polluted urban rivers challenges the drinking water treatment, yet it is often neglected. The CDOM is a valuable parameter for assessing CDOM in water and identifying potential hazards and hazardous events in water safety plans. Aim: This study was aimed to quantify CDOM and common water quality parameters along a conventional water treatment plant (WTP) treating polluted raw water in Indonesia, and investigate common water quality-CDOM parameters relationships. Hazards and hazardous events were identified throughout different treatment stages, and the risks were assessed. Methodology and results: The measured common water quality parameters included turbidity, pH, electroconductivity, and potassium permanganate, and the CDOM absorption coefficients were determined at 254 nm (A254), 298 nm (A298), and 355nm (A355). The WTP was able to reduce the turbidity >80%, and permanganate up to 71%. Meanwhile the CDOM parameters overall removal were 23-29%. The results show there were no strong relationships between the common and CDOM parameters. Only turbidity exhibited a significant but weak correlation with A254 and A298, and very weak correlation between each common parameter and A355, suggesting common parameters were inadequate as surrogates for CDOM monitoring. Conclusion, significance and impact study: The WTP could not reduce the CDOM optimally, leading to the occurrence of hazardous events in the WTP. The identified hazardous events were attributable to external cause in the catchment, inappropriate operations of coagulation and filtration process, inappropriate chlorine dose and chlorination system design, and poor maintenance of the reservoir.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 128 tautan kepenulisan bersama · 48 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Nasional Bandung
  • Bandung Institute of Technology
  • National Research and Innovation Agency
  • Indonesian Institute of Sciences
  • International University
  • Tokyo Institute of Technology
  • Universitas Airlangga
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Lisa KristianaInstitut Teknologi Nasional Bandung3
Ahmad Soleh SetiyawanBandung Institute of Technology3
Lita LidyawatiInstitut Teknologi Nasional Bandung3
Yusuf Eka MaulanaBandung Institute of Technology3
Dwina RoosminiBandung Institute of Technology3
Suprihanto NotodarmojoBandung Institute of Technology3
Lucia JambolaInstitut Teknologi Nasional Bandung2
Prayatni SoewondoBandung Institute of Technology2
Dyah Wulandari PutriBandung Institute of Technology2
Andre WiduraInstitut Teknologi Nasional Bandung1
Muhamad Rifan AndrianInstitut Teknologi Nasional Bandung1
Irma Amelia DewiInstitut Teknologi Nasional Bandung1
Windi MalahaInstitut Teknologi Nasional Bandung1
DWI ARYANTAInstitut Teknologi Nasional Bandung1
Zaidan Al ArsyadBandung Institute of Technology1
Faiz MunirBandung Institute of Technology1
Amanda AllawiyahBandung Institute of Technology1
Tiara SaniaBandung Institute of Technology1
I Putu HartawanBandung Institute of Technology1
Farisah Inarah Rahmat HasbyBandung Institute of Technology1
Chihiro YoshimuraTokyo Institute of Technology1
Etih HartatiInstitut Teknologi Nasional Bandung1
Faradilla Rizqi TrisaniInstitut Teknologi Nasional Bandung1
Rea Ramada JayandanuInstitut Teknologi Nasional Bandung1
Sofa Jauharotul MunawarohInstitut Teknologi Nasional Bandung1
Dyah MarganingrumIndonesian Institute of Sciences1
Asep MulyonoNational Research and Innovation Agency1
Ratna Dwi Puji AstutiUniversitas Airlangga1
Rizka MariaIndonesian Institute of Sciences1
Anna Fadliah RusydiNational Research and Innovation Agency1
Heri NurohmanNational Research and Innovation Agency1
Eki Naidania DidaNational Research and Innovation Agency1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210216775, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Integration of Chromophoric Dissolved Organic Matter Quantification into Water Safety Plans at Urban Conventional Treatment Plants</dc:title><dc:creator>Mohamad Rangga Sururi</dc:creator><dc:creator>Mila Dirgawati</dc:creator><dc:creator>Khairunnisa Dwita Lestari</dc:creator><dc:creator>Detizca Millenna Nugraha</dc:creator><dc:creator>Arsyad Ramadhan Darlis</dc:creator><dc:creator>Ajeng Hartini Dewi</dc:creator><dc:creator>Prama Setia Putra</dc:creator><dc:creator>Vandith Va</dc:creator><dc:subject>colored dissolved organic matter</dc:subject><dc:subject>water safety plans</dc:subject><dc:subject>CDOM absorption coefficient</dc:subject><dc:subject>turbidity</dc:subject><dc:subject>potassium permanganate</dc:subject><dc:subject>chlorination</dc:subject><dc:subject>reservoir maintenance</dc:subject><dc:subject>hazardous events</dc:subject><dc:subject>water quality parameters</dc:subject><dc:description xml:lang="en">The presence of chromophoric dissolved organic matter (CDOM) in polluted urban rivers challenges the drinking water treatment, yet it is often neglected. The CDOM is a valuable parameter for assessing CDOM in water and identifying potential hazards and hazardous events in water safety plans. Aim: This study was aimed to quantify CDOM and common water quality parameters along a conventional water treatment plant (WTP) treating polluted raw water in Indonesia, and investigate common water quality-CDOM parameters relationships. Hazards and hazardous events were identified throughout different treatment stages, and the risks were assessed. Methodology and results: The measured common water quality parameters included turbidity, pH, electroconductivity, and potassium permanganate, and the CDOM absorption coefficients were determined at 254 nm (A254), 298 nm (A298), and 355nm (A355). The WTP was able to reduce the turbidity &gt;80%, and permanganate up to 71%. Meanwhile the CDOM parameters overall removal were 23-29%. The results show there were no strong relationships between the common and CDOM parameters. Only turbidity exhibited a significant but weak correlation with A254 and A298, and very weak correlation between each common parameter and A355, suggesting common parameters were inadequate as surrogates for CDOM monitoring. Conclusion, significance and impact study: The WTP could not reduce the CDOM optimally, leading to the occurrence of hazardous events in the WTP. The identified hazardous events were attributable to external cause in the catchment, inappropriate operations of coagulation and filtration process, inappropriate chlorine dose and chlorination system design, and poor maintenance of the reservoir.</dc:description><dc:publisher>Universitas Trisakti</dc:publisher><dc:date>2026-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25105/urbanenvirotech.v9i2.24290</dc:identifier><dc:identifier>10.25105/urbanenvirotech.v9i2.24290</dc:identifier><dc:source>INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY; (2026); 473-492</dc:source><dc:source>2579-9150</dc:source><dc:source>2579-9207</dc:source><dc:language>en</dc:language><dc:relation>https://e-journal.trisakti.ac.id/index.php/urbanenvirotech/article/download/24290/14787</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights></oai_dc:dc>