Design and Implementation of IoT-Based Water Pipe Pressure Monitoring Instrument

Jurnal Elektronika dan Telekomunikasi · Vol. 21 No. 1 (2021) · hlm. 41–47

DOI
10.14203/jet.v21.41-44
ISSN
1411-8289, 2527-9955
Terbit
2021-08-31
Penerbit
Indonesian Institute of Sciences
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

The water pressure monitoring system in the PDAM pipeline networks has been successfully developed for operation and maintenance of water leaks in a real-time manner. This research aims to design a water pressure monitoring system in operational piping networks to identify anomalies as early as possible. The system is built using a microcontroller, a 1.2 MPa fluid pressure sensor and a control system equipped with a GSM wireless communication module, an Analog to Digital Converter module with 16-bit resolution, a real-time clock peripheral, an OLED display 128x64, and a micro SD card. The developed system was tested in a pressure range of 0.200 - 0.800 bar with 30 repetitions with a RMSE of 0.058 bar. This system has a deterministic coefficient of 0.885 against a standard manometer. The system implemented in the field successfully sends data to the server with a success rate of 96.0%. Data is displayed on a monitoring dashboard that can be accessed via a computer or smartphone.

Kata kunci

Jaringan kolaborasi para penulis

20 penulis · 68 tautan kepenulisan bersama · 30 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Jambi
  • Universitas Maritim Raja Ali Haji
  • IPB University
  • National Research and Innovation Agency
  • Universitas Djuanda
  • Politeknik Negeri Batam
  • Instytut Oceanologii Polskiej Akademii Nauk
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tonny SuhendraUniversitas Maritim Raja Ali Haji2
Dwi Eny Djoko SetyonoNational Research and Innovation Agency2
Muhammad RidoUniversitas Jambi1
Kania Nur SawitriUniversitas Jambi1
Aris IrvanUniversitas Jambi1
Oky Lidya KumalaUniversitas Jambi1
Jajang NurjamanUniversitas Jambi1
Helni Kurniawati ZebuaUniversitas Jambi1
Eka Fitri AndiniUniversitas Jambi1
Lia AmaliaUniversitas Djuanda1
Muhammad Zainuddin LubisPoliteknik Negeri Batam1
Aidil Fadli IlhamdyUniversitas Maritim Raja Ali Haji1
Carel Candigia Sahid IlhamiUniversitas Maritim Raja Ali Haji1
Dhanushka DevendraInstytut Oceanologii Polskiej Akademii Nauk1
Yuliani YulianiUniversitas Maritim Raja Ali Haji1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210212760, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design and Implementation of IoT-Based Water Pipe Pressure Monitoring Instrument</dc:title><dc:creator>Hollanda Arief Kusuma</dc:creator><dc:creator>Rady Purbakawaca</dc:creator><dc:creator>Irwan Rudy Pamungkas</dc:creator><dc:creator>Luthfy Nizarul Fikry</dc:creator><dc:creator>Sonny Seftian Maulizar</dc:creator><dc:subject>Internet of Things</dc:subject><dc:subject>water distribution systems</dc:subject><dc:subject>water leakage detection</dc:subject><dc:subject>pressure sensors</dc:subject><dc:subject>GSM wireless communication</dc:subject><dc:subject>microcontroller</dc:subject><dc:subject>real-time monitoring</dc:subject><dc:subject>monitoring dashboard</dc:subject><dc:subject>PDAM</dc:subject><dc:description xml:lang="en">The water pressure monitoring system in the PDAM pipeline networks has been successfully developed for operation and maintenance of water leaks in a real-time manner. This research aims to design a water pressure monitoring system in operational piping networks to identify anomalies as early as possible. The system is built using a microcontroller, a 1.2 MPa fluid pressure sensor and a control system equipped with a GSM wireless communication module, an Analog to Digital Converter module with 16-bit resolution, a real-time clock peripheral, an OLED display 128x64, and a micro SD card. The developed system was tested in a pressure range of 0.200 - 0.800 bar with 30 repetitions with a RMSE of 0.058 bar. This system has a deterministic coefficient of 0.885 against a standard manometer. The system implemented in the field successfully sends data to the server with a success rate of 96.0%. Data is displayed on a monitoring dashboard that can be accessed via a computer or smartphone.</dc:description><dc:publisher>Indonesian Institute of Sciences</dc:publisher><dc:date>2021-08-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14203/jet.v21.41-44</dc:identifier><dc:identifier>10.14203/jet.v21.41-44</dc:identifier><dc:source>Jurnal Elektronika dan Telekomunikasi; Vol 21 No 1 (2021); 41-47</dc:source><dc:source>1411-8289</dc:source><dc:source>2527-9955</dc:source><dc:language>en</dc:language><dc:relation>https://www.jurnalet.com/jet/article/download/400/343</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>