Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Phase-Sensitive Radar Using ADALM-Pluto SDR and Cantenna for Sub-Millimeter Displacement Measurement

Jurnal Elektronika dan Telekomunikasi · Vol. 25 No. 2 (2025) · hlm. 126–140

DOI
10.55981/jet.757
ISSN
1411-8289, 2527-9955
Terbit
2025-12-31
Penerbit
Indonesian Institute of Sciences
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

The capability of phase-sensitive radar to detect sub-millimeter displacement has been widely demonstrated, enabling a range of applications such as structural vibration monitoring, human vital-sign detection, gesture sensing, and precision motion tracking. In these domains, particularly in non-contact human respiratory monitoring, conventional phase-sensitive radar systems offer key advantages, including high phase stability, robust performance under non-ideal lighting or environmental conditions, and the ability to operate without physical contact. These strengths make them effective for capturing small periodic chest movements required for accurate respiratory assessment. However, conventional hardware implementations often suffer from limited flexibility, higher development cost, and increased design complexity. These constraints motivate the shift toward software-defined radio (SDR) solutions, which provide reconfigurability, simplified prototyping, and significantly lower cost while retaining the essential phase-sensitive capabilities. This motivation forms the basis of the present research. This study realizes a phase-sensitive radar using an ADALM-Pluto SDR operating at 2.45 GHz with a cantenna antenna configuration. Compared with previous SDR-based works that focus primarily on Doppler vital-sign extraction or require more elaborate RF front-ends, the proposed system emphasizes displacement-resolution enhancement through careful phase processing while maintaining minimal hardware complexity. The combination of a compact SDR platform, simple antenna structure, and optimized signal processing pipeline yields a practical and accessible radar prototype. Experimental results demonstrate that the proposed system achieves a displacement resolution of 0.5 mm, meeting the requirements for developing a reliable respiratory-monitoring application and confirming the suitability of SDR-based phase-sensitive radar for low-cost biomedical sensing.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 32 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Bandung
  • Indonesian Institute of Sciences
  • National Research and Innovation Agency
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Hepi LudiyatiPoliteknik Negeri Bandung1
Aqiila Putri Zharfani AshlahPoliteknik Negeri Bandung1
Erika Dwi JayantiPoliteknik Negeri Bandung1
Hanny MadiawatiPoliteknik Negeri Bandung1
Yaya SulaemanIndonesian Institute of Sciences1
Asep Yudi HercuadiIndonesian Institute of Sciences1
Yana TaryanaNational Research and Innovation Agency1
Farrah VauziaPoliteknik Negeri Bandung1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210212760, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Phase-Sensitive Radar Using ADALM-Pluto SDR and Cantenna for Sub-Millimeter Displacement Measurement</dc:title><dc:creator>Eril Mozef</dc:creator><dc:creator>Ridho Shofwan Rasyid</dc:creator><dc:creator>Enceng Sulaeman</dc:creator><dc:creator>Tiyo Rizky Mulyana</dc:creator><dc:creator>Fahrizal Al Farik</dc:creator><dc:creator>Thaskia Qolbi Junjunan</dc:creator><dc:subject>phase-sensitive radar</dc:subject><dc:subject>software-defined radio</dc:subject><dc:subject>ADALM-PLUTO</dc:subject><dc:subject>respiratory monitoring</dc:subject><dc:subject>2.45 GHz</dc:subject><dc:subject>displacement resolution</dc:subject><dc:description xml:lang="en">The capability of phase-sensitive radar to detect sub-millimeter displacement has been widely demonstrated, enabling a range of applications such as structural vibration monitoring, human vital-sign detection, gesture sensing, and precision motion tracking. In these domains, particularly in non-contact human respiratory monitoring, conventional phase-sensitive radar systems offer key advantages, including high phase stability, robust performance under non-ideal lighting or environmental conditions, and the ability to operate without physical contact. These strengths make them effective for capturing small periodic chest movements required for accurate respiratory assessment. However, conventional hardware implementations often suffer from limited flexibility, higher development cost, and increased design complexity. These constraints motivate the shift toward software-defined radio (SDR) solutions, which provide reconfigurability, simplified prototyping, and significantly lower cost while retaining the essential phase-sensitive capabilities. This motivation forms the basis of the present research. This study realizes a phase-sensitive radar using an ADALM-Pluto SDR operating at 2.45 GHz with a cantenna antenna configuration. Compared with previous SDR-based works that focus primarily on Doppler vital-sign extraction or require more elaborate RF front-ends, the proposed system emphasizes displacement-resolution enhancement through careful phase processing while maintaining minimal hardware complexity. The combination of a compact SDR platform, simple antenna structure, and optimized signal processing pipeline yields a practical and accessible radar prototype. Experimental results demonstrate that the proposed system achieves a displacement resolution of 0.5 mm, meeting the requirements for developing a reliable respiratory-monitoring application and confirming the suitability of SDR-based phase-sensitive radar for low-cost biomedical sensing.</dc:description><dc:publisher>Indonesian Institute of Sciences</dc:publisher><dc:date>2025-12-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.55981/jet.757</dc:identifier><dc:identifier>10.55981/jet.757</dc:identifier><dc:source>Jurnal Elektronika dan Telekomunikasi; Vol 25 No 2 (2025); 126-140</dc:source><dc:source>1411-8289</dc:source><dc:source>2527-9955</dc:source><dc:language>en</dc:language><dc:relation>https://www.jurnalet.com/jet/article/download/757/533</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>