Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Microcontroller-Based Lead-Acid Battery Balancing System for Electric Vehicle Applications

Jurnal Elektronika dan Telekomunikasi · Vol. 21 No. 2 (2021) · hlm. 128–139

DOI
10.14203/jet.v21.128-139
ISSN
1411-8289, 2527-9955
Terbit
2021-12-31
Penerbit
Indonesian Institute of Sciences
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

In application of lead-acid batteries for electrical vehicle applications, 48 V of four 12 V batteries in a series configuration are required. However, the battery stack is repeatedly charged and discharged during operation. Hence, differences in charging and discharging speeds may result in a different state-of-charge of battery cells. Without proper protection, it may cause an excessive discharge that leads to premature degradation of the battery. Therefore, a lead-acid battery requires a battery management system to extend the battery lifetime. Following the LTC3305 balancing scheme, the battery balancing circuit with auxiliary storage can employ an imbalance detection algorithm for sequential battery. It happens by comparing the voltage of a battery on the stack and the auxiliary storage. In this paper, we have replaced the function of LTC3305 by a NUCLEO F767ZI microcontroller, so that the balancing process, the battery voltage, the drawn current to or from the auxiliary battery, and the surrounding temperature can be fully monitored. The prototype of a microcontroller-based lead-acid battery balancing system for electrical vehicle application has been fabricated successfully in this work. The batteries voltage monitoring, the auxiliary battery drawn current monitoring, the overcurrent and overheat protection system of this device has also successfully built. Based on the experimental results, the largest voltage imbalance is between battery 1 and battery 2 with a voltage imbalance of 180 mV. This value is still higher than the target of voltage imbalance that must be lower than 12.5 mV. The balancing process for the timer mode operation is faster 1.5 times compared to the continuous mode operation. However, there were no overcurrent or overtemperature occurred during the balancing process for both timer mode and continuous mode operation. Furthermore, refinement of this device prototype is required in the future to improve the performance significantly.

Kata kunci

Jaringan kolaborasi para penulis

11 penulis · 20 tautan kepenulisan bersama · 15 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • President University
  • Politeknik Astra
  • Manchester Metropolitan University
  • Aalto University
  • Universitas Ahmad Dahlan
  • Mississippi College
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tole SutiknoUniversitas Ahmad Dahlan1
Dodi GarintoPoliteknik Astra1
Theodora ValerieAalto University1
Harki Apri YantoPoliteknik Astra1
Hendra Jaya TariganMississippi College1
Lydia AnggrainiPresident University1
Wilbert WijayaPresident University1
David TylerManchester Metropolitan University1
Clémentine MavridisManchester Metropolitan University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210212760, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Microcontroller-Based Lead-Acid Battery Balancing System for Electric Vehicle Applications</dc:title><dc:creator>Ali Rospawan</dc:creator><dc:creator>Joni Welman Simatupang</dc:creator><dc:subject>battery management systems</dc:subject><dc:subject>electric vehicles</dc:subject><dc:subject>auxiliary battery</dc:subject><dc:subject>overcurrent protection</dc:subject><dc:subject>overtemperature protection</dc:subject><dc:subject>battery degradation</dc:subject><dc:description xml:lang="en">In application of lead-acid batteries for electrical vehicle applications, 48 V of four 12 V batteries in a series configuration are required. However, the battery stack is repeatedly charged and discharged during operation. Hence, differences in charging and discharging speeds may result in a different state-of-charge of battery cells. Without proper protection, it may cause an excessive discharge that leads to premature degradation of the battery. Therefore, a lead-acid battery requires a battery management system to extend the battery lifetime. Following the LTC3305 balancing scheme, the battery balancing circuit with auxiliary storage can employ an imbalance detection algorithm for sequential battery. It happens by comparing the voltage of a battery on the stack and the auxiliary storage. In this paper, we have replaced the function of LTC3305 by a NUCLEO F767ZI microcontroller, so that the balancing process, the battery voltage, the drawn current to or from the auxiliary battery, and the surrounding temperature can be fully monitored. The prototype of a microcontroller-based lead-acid battery balancing system for electrical vehicle application has been fabricated successfully in this work. The batteries voltage monitoring, the auxiliary battery drawn current monitoring, the overcurrent and overheat protection system of this device has also successfully built. Based on the experimental results, the largest voltage imbalance is between battery 1 and battery 2 with a voltage imbalance of 180 mV. This value is still higher than the target of voltage imbalance that must be lower than 12.5 mV. The balancing process for the timer mode operation is faster 1.5 times compared to the continuous mode operation. However, there were no overcurrent or overtemperature occurred during the balancing process for both timer mode and continuous mode operation. Furthermore, refinement of this device prototype is required in the future to improve the performance significantly.</dc:description><dc:publisher>Indonesian Institute of Sciences</dc:publisher><dc:date>2021-12-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.14203/jet.v21.128-139</dc:identifier><dc:identifier>10.14203/jet.v21.128-139</dc:identifier><dc:source>Jurnal Elektronika dan Telekomunikasi; Vol 21 No 2 (2021); 128-139</dc:source><dc:source>1411-8289</dc:source><dc:source>2527-9955</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>