Active Filter Analysis on Designing Electronic Stethoscope
Jurnal Elektronika dan Telekomunikasi · Vol. 19 No. 2 (2019) · hlm. 51–56
ISSN 1411-8289, 2527-9955
Terbit 2019-12-31
Penerbit Indonesian Institute of Sciences
Bahasa en
Abstrak
Early heart disease detection could be vital and some other diagnostic ways are being developed. In this paper, a lowcost tool for a diagnostic that analyzes the digitized heartbeat sound is given. This can be used to detect heart anomalies. The instrument shows the heart sound and also keeps a patient's long-term record for future use. The signal from the heart provides a lot of knowledge about the heart and offers an initial diagnosis recommendation. The electronic stethoscope uses the condenser microphone, preamplifier circuit, and filter circuit. The optimum filter is Butterworth with a fourth-order Sallen key low pass filter topology with a gain of 0.707 volts, -3.01 dB, and a fourth-order high pass filter with a gain of 0.782 volts, -2.137 dB. The frequency of the heart sound is about 20 Hz – 120 Hz in general. Therefore, the lower cutoff frequency of the filter is set to 20 Hz, while the higher cutoff frequency set to 120 Hz. The evaluation used to measure the performance of an electronic stethoscope is to compare with a conventional stethoscope, the recorded sound is the same.
Jaringan kolaborasi para penulis
19 penulis ·
46 tautan kepenulisan bersama
· 20 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Jakarta State Polytechnic Mercu Buana University IPB University Indonesian National Institute of Aeronautics and Space National Defence University of Malaysia
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210212760, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Active Filter Analysis on Designing Electronic Stethoscope</dc:title><dc:creator>Prihatin Oktivasari</dc:creator><dc:creator>Riandini Riandini</dc:creator><dc:creator>Rahmah A. Fitri</dc:creator><dc:creator>Sungguh I. Malaon</dc:creator><dc:subject>electronic stethoscope</dc:subject><dc:subject>heart sound analysis</dc:subject><dc:subject>active filter design</dc:subject><dc:subject>Sallen-Key filter</dc:subject><dc:subject>Butterworth filter</dc:subject><dc:subject>low-cost medical device</dc:subject><dc:subject>heart disease detection</dc:subject><dc:subject>condenser microphone</dc:subject><dc:subject>preamplifier circuit</dc:subject><dc:subject>low-pass and high-pass filtering</dc:subject><dc:subject>phonocardiography</dc:subject><dc:description xml:lang="en">Early heart disease detection could be vital and some other diagnostic ways are being developed. In this paper, a lowcost tool for a diagnostic that analyzes the digitized heartbeat sound is given. This can be used to detect heart anomalies. The instrument shows the heart sound and also keeps a patient's long-term record for future use. The signal from the heart provides a lot of knowledge about the heart and offers an initial diagnosis recommendation. The electronic stethoscope uses the condenser microphone, preamplifier circuit, and filter circuit. The optimum filter is Butterworth with a fourth-order Sallen key low pass filter topology with a gain of 0.707 volts, -3.01 dB, and a fourth-order high pass filter with a gain of 0.782 volts, -2.137 dB. The frequency of the heart sound is about 20 Hz – 120 Hz in general. Therefore, the lower cutoff frequency of the filter is set to 20 Hz, while the higher cutoff frequency set to 120 Hz. The evaluation used to measure the performance of an electronic stethoscope is to compare with a conventional stethoscope, the recorded sound is the same.</dc:description><dc:publisher>Indonesian Institute of Sciences</dc:publisher><dc:date>2019-12-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14203/jet.v19.51-56</dc:identifier><dc:identifier>10.14203/jet.v19.51-56</dc:identifier><dc:source>Jurnal Elektronika dan Telekomunikasi; Vol 19 No 2 (2019); 51-56</dc:source><dc:source>1411-8289</dc:source><dc:source>2527-9955</dc:source><dc:language>en</dc:language><dc:relation>https://www.jurnalet.com/jet/article/download/278/260</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
4 sitasi
Crossref
Terindeks
lewat DOI
2 sitasi
Jumlah menurut tiap indeks pada 21 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Oktivasari, P., Riandini, R., Fitri, R. A., & Malaon, S. I. (2019). Active Filter Analysis on Designing Electronic Stethoscope. Jurnal Elektronika dan Telekomunikasi, 19(2), 51–56. https://doi.org/10.14203/jet.v19.51-56
Salin
IEEE
P. Oktivasari, R. Riandini, R. A. Fitri, and S. I. Malaon, “Active Filter Analysis on Designing Electronic Stethoscope,” Jurnal Elektronika dan Telekomunikasi, vol. 19, no. 2, pp. 51–56, 2019, doi: 10.14203/jet.v19.51-56.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.