Active Filter Analysis on Designing Electronic Stethoscope

Jurnal Elektronika dan Telekomunikasi · Vol. 19 No. 2 (2019) · hlm. 51–56

DOI
10.14203/jet.v19.51-56
ISSN
1411-8289, 2527-9955
Terbit
2019-12-31
Penerbit
Indonesian Institute of Sciences
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

Early heart disease detection could be vital and some other diagnostic ways are being developed. In this paper, a lowcost tool for a diagnostic that analyzes the digitized heartbeat sound is given. This can be used to detect heart anomalies. The instrument shows the heart sound and also keeps a patient's long-term record for future use. The signal from the heart provides a lot of knowledge about the heart and offers an initial diagnosis recommendation. The electronic stethoscope uses the condenser microphone, preamplifier circuit, and filter circuit. The optimum filter is Butterworth with a fourth-order Sallen key low pass filter topology with a gain of 0.707 volts, -3.01 dB, and a fourth-order high pass filter with a gain of 0.782 volts, -2.137 dB. The frequency of the heart sound is about 20 Hz – 120 Hz in general. Therefore, the lower cutoff frequency of the filter is set to 20 Hz, while the higher cutoff frequency set to 120 Hz. The evaluation used to measure the performance of an electronic stethoscope is to compare with a conventional stethoscope, the recorded sound is the same.

Kata kunci

Jaringan kolaborasi para penulis

19 penulis · 46 tautan kepenulisan bersama · 20 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jakarta State Polytechnic
  • Mercu Buana University
  • IPB University
  • Indonesian National Institute of Aeronautics and Space
  • National Defence University of Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rika Novita WardhaniJakarta State Polytechnic3
Sulis SetiowatiJakarta State Polytechnic2
Rinto PriambodoMercu Buana University2
Zendi IklimaMercu Buana University2
Trie Maya KadarinaMercu Buana University2
Murie DwiyanitiJakarta State Polytechnic1
Eddy SupriyonoIPB University1
Satria Arief AdityaIndonesian National Institute of Aeronautics and Space1
Mohd Taufik JusohNational Defence University of Malaysia1
Muhammad Angga Aji Bagus PangestuJakarta State Polytechnic1
Ghaisani YasminJakarta State Polytechnic1
Muda Wali Samudra PasaiJakarta State Polytechnic1
Mustofa MustofaJakarta State Polytechnic1
Royhan RoyhanJakarta State Polytechnic1
Asep KurniawanJakarta State Polytechnic1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210212760, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Active Filter Analysis on Designing Electronic Stethoscope</dc:title><dc:creator>Prihatin Oktivasari</dc:creator><dc:creator>Riandini Riandini</dc:creator><dc:creator>Rahmah A. Fitri</dc:creator><dc:creator>Sungguh I. Malaon</dc:creator><dc:subject>electronic stethoscope</dc:subject><dc:subject>heart sound analysis</dc:subject><dc:subject>active filter design</dc:subject><dc:subject>Sallen-Key filter</dc:subject><dc:subject>Butterworth filter</dc:subject><dc:subject>low-cost medical device</dc:subject><dc:subject>heart disease detection</dc:subject><dc:subject>condenser microphone</dc:subject><dc:subject>preamplifier circuit</dc:subject><dc:subject>low-pass and high-pass filtering</dc:subject><dc:subject>phonocardiography</dc:subject><dc:description xml:lang="en">Early heart disease detection could be vital and some other diagnostic ways are being developed. In this paper, a lowcost tool for a diagnostic that analyzes the digitized heartbeat sound is given. This can be used to detect heart anomalies. The instrument shows the heart sound and also keeps a patient's long-term record for future use. The signal from the heart provides a lot of knowledge about the heart and offers an initial diagnosis recommendation. The electronic stethoscope uses the condenser microphone, preamplifier circuit, and filter circuit. The optimum filter is Butterworth with a fourth-order Sallen key low pass filter topology with a gain of 0.707 volts, -3.01 dB, and a fourth-order high pass filter with a gain of 0.782 volts, -2.137 dB. The frequency of the heart sound is about 20 Hz – 120 Hz in general. Therefore, the lower cutoff frequency of the filter is set to 20 Hz, while the higher cutoff frequency set to 120 Hz. The evaluation used to measure the performance of an electronic stethoscope is to compare with a conventional stethoscope, the recorded sound is the same.</dc:description><dc:publisher>Indonesian Institute of Sciences</dc:publisher><dc:date>2019-12-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14203/jet.v19.51-56</dc:identifier><dc:identifier>10.14203/jet.v19.51-56</dc:identifier><dc:source>Jurnal Elektronika dan Telekomunikasi; Vol 19 No 2 (2019); 51-56</dc:source><dc:source>1411-8289</dc:source><dc:source>2527-9955</dc:source><dc:language>en</dc:language><dc:relation>https://www.jurnalet.com/jet/article/download/278/260</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>