Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Cardiac Imaging with Electrical Impedance Tomography (EIT) using Multilayer Perceptron Network

Jurnal Elektronika dan Telekomunikasi · Vol. 25 No. 1 (2025) · hlm. 55–63

DOI
10.55981/jet.705
ISSN
1411-8289, 2527-9955
Terbit
2025-08-31
Penerbit
Indonesian Institute of Sciences
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

This research explores the enhancement of Electrical Impedance Tomography (EIT) for cardiac imaging using Multilayer Perceptron (MLP) networks, focusing on supervised and semi-supervised learning approaches. Using synthetic thoracic datasets simulating dynamic cardiac and respiratory conditions, the study demonstrates that supervised learning achieves lower mean squared error (MSE) values (minimum 4.76) and more stable predictions compared to semi-supervised learning (minimum MSE 5.08). However, semi-supervised learning excels in edge accuracy and noise reduction, particularly in regions with sharp conductivity gradients, making it viable for scenarios with limited labeled data. Dropout regularization at 0.3 provided optimal balance, enhancing model generalization and robustness. While supervised learning outperformed semi-supervised methods in overall accuracy, the latter showed potential for cost-effective and scalable applications in EIT-based cardiac imaging. These findings suggest that integrating advanced machine learning with EIT can improve diagnostic accuracy and enable efficient use of sparse labeled data, paving the way for future optimizations and clinical applications.

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 56 tautan kepenulisan bersama · 32 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Research and Innovation Agency
  • Universitas Negeri Surabaya
  • Universitas PGRI Semarang
  • Sunan Kalijaga State Islamic University Yogyakarta
  • Bandung Institute of Technology
  • Universitas Jambi
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Affandi Faisal KurniawanUniversitas PGRI Semarang2
Wawan KurniawanUniversitas Jambi2
Joko SaefanUniversitas PGRI Semarang2
Sulistia SulistiaUniversitas PGRI Semarang2
Riyanto RiyantoNational Research and Innovation Agency2
Nita HandayaniSunan Kalijaga State Islamic University Yogyakarta1
Freddy HaryantoBandung Institute of Technology1
Warsito Purwo TarunoAfiliasi tidak diketahui1
Kharisma Fajar HidayantiSunan Kalijaga State Islamic University Yogyakarta1
Siti Nurul KhotimahBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210212760, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Cardiac Imaging with Electrical Impedance Tomography (EIT) using Multilayer Perceptron Network</dc:title><dc:creator>Amelia Putri Ristyawardani</dc:creator><dc:creator>Marlin Ramadhan Baidillah</dc:creator><dc:creator>Yudi Adityawarman</dc:creator><dc:creator>Pratondo Busono</dc:creator><dc:creator>Mochamad Adityo Rachmadi</dc:creator><dc:creator>Meta Yantidewi</dc:creator><dc:creator>Endah Rahmawati</dc:creator><dc:subject>electrical impedance tomography</dc:subject><dc:subject>cardiac imaging</dc:subject><dc:subject>multilayer perceptron</dc:subject><dc:subject>semi-supervised learning</dc:subject><dc:subject>supervised learning</dc:subject><dc:subject>dropout regularization</dc:subject><dc:subject>conductivity reconstruction</dc:subject><dc:subject>noise reduction</dc:subject><dc:subject>limited labeled data</dc:subject><dc:description xml:lang="en">This research explores the enhancement of Electrical Impedance Tomography (EIT) for cardiac imaging using Multilayer Perceptron (MLP) networks, focusing on supervised and semi-supervised learning approaches. Using synthetic thoracic datasets simulating dynamic cardiac and respiratory conditions, the study demonstrates that supervised learning achieves lower mean squared error (MSE) values (minimum 4.76) and more stable predictions compared to semi-supervised learning (minimum MSE 5.08). However, semi-supervised learning excels in edge accuracy and noise reduction, particularly in regions with sharp conductivity gradients, making it viable for scenarios with limited labeled data. Dropout regularization at 0.3 provided optimal balance, enhancing model generalization and robustness. While supervised learning outperformed semi-supervised methods in overall accuracy, the latter showed potential for cost-effective and scalable applications in EIT-based cardiac imaging. These findings suggest that integrating advanced machine learning with EIT can improve diagnostic accuracy and enable efficient use of sparse labeled data, paving the way for future optimizations and clinical applications.</dc:description><dc:publisher>Indonesian Institute of Sciences</dc:publisher><dc:date>2025-08-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.55981/jet.705</dc:identifier><dc:identifier>10.55981/jet.705</dc:identifier><dc:source>Jurnal Elektronika dan Telekomunikasi; Vol 25 No 1 (2025); 55-63</dc:source><dc:source>1411-8289</dc:source><dc:source>2527-9955</dc:source><dc:language>en</dc:language><dc:relation>https://www.jurnalet.com/jet/article/download/705/518</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>