Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Fluid Flow Rates Regression in Tank Level Control

CHEESA Chemical Engineering Research Articles · Vol. 8 No. 1 (2025) · hlm. 35–42

DOI
10.25273/cheesa.v8i1.21400.35-42
ISSN
2614-8757, 2615-2347
Terbit
2025-08-21
Penerbit
Universitas PGRI Madiun
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

The industrial production process is closely related to control systems, including level control. This is often used to ensure that fluid in the tank is available in the appropriate amount at each stage of the process. The process typically uses an automatic control system such as a Proportional Integral Derivative (PID) Controller that can help measure the accuracy of the data obtained. Therefore, this study aims to examine the effect of flow rate on fluid level control in a tank using linear, exponential, and logarithmic regression analyses. In the process, the effect of the automatic control system (PID Controller) on fluid flow rate was evaluated. The materials used were a 4 mm solenoid and a pump speed variation in the range of 30-50%. Data on fluid level increase were obtained at 0 (n = 1), 60.27 (n = 30), and 180 seconds (n = 61) as the lower, middle, and upper limits. The results showed that fluid flow rate significantly affected the process of controlling fluid level in the tank, and is influenced by the speed of the pump used. Based on the regression analysis, the evaluation of the PID Controller was still classified as good, because the deviation observed in the reading flow rate data was very small.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 10 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Chulalongkorn University
  • Politeknik ATI Padang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175359, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Fluid Flow Rates Regression in Tank Level Control</dc:title><dc:creator>Puji Sri Rahayu</dc:creator><dc:creator>Khairunisa Betariani</dc:creator><dc:creator>Rachmadi Tutuka</dc:creator><dc:creator>Ari Adrianto</dc:creator><dc:creator>Nurmalasari</dc:creator><dc:subject>tank level control</dc:subject><dc:subject>fluid flow rate</dc:subject><dc:subject>PID controller</dc:subject><dc:subject>solenoid valve</dc:subject><dc:subject>pump speed</dc:subject><dc:subject>linear regression</dc:subject><dc:subject>exponential regression</dc:subject><dc:subject>logarithmic regression</dc:subject><dc:subject>process control</dc:subject><dc:description xml:lang="en">The industrial production process is closely related to control systems, including level control. This is often used to ensure that fluid in the tank is available in the appropriate amount at each stage of the process. The process typically uses an automatic control system such as a Proportional Integral Derivative (PID) Controller that can help measure the accuracy of the data obtained. Therefore, this study aims to examine the effect of flow rate on fluid level control in a tank using linear, exponential, and logarithmic regression analyses. In the process, the effect of the automatic control system (PID Controller) on fluid flow rate was evaluated. The materials used were a 4 mm solenoid and a pump speed variation in the range of 30-50%. Data on fluid level increase were obtained at 0 (n = 1), 60.27 (n = 30), and 180 seconds (n = 61) as the lower, middle, and upper limits. The results showed that fluid flow rate significantly affected the process of controlling fluid level in the tank, and is influenced by the speed of the pump used. Based on the regression analysis, the evaluation of the PID Controller was still classified as good, because the deviation observed in the reading flow rate data was very small.</dc:description><dc:publisher>Universitas PGRI Madiun</dc:publisher><dc:date>2025-08-21</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25273/cheesa.v8i1.21400.35-42</dc:identifier><dc:identifier>10.25273/cheesa.v8i1.21400.35-42</dc:identifier><dc:source>CHEESA Chemical Engineering Research Articles; Vol 8 No 1 (2025); 35-42</dc:source><dc:source>2614-8757</dc:source><dc:source>2615-2347</dc:source><dc:language>en</dc:language><dc:relation>https://e-journal.unipma.ac.id/index.php/cheesa/article/download/21400/7432</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>