Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Deep Transfer Learning Networks for Brain Tumor Detection: The Effect of MRI Patient Image Augmentation Methods

International Journal of Electronics and Communications Systems · Vol. 2 No. 2 (2022) · hlm. 39–48

DOI
10.24042/ijecs.v2i2.14815
ISSN
2798-2610
Terbit
2022-12-25
Penerbit
UIN Raden Intan Lampung
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The exponential growth of deep learning networks has enabled us to handle difficult tasks, even in the complex field of medicine with small datasets. In the sphere of treatment, they are particularly significant. To identify brain tumors, this research examines how three deep learning networks are affected by conventional data augmentation methods, including MobileNetV2, VGG19, and DenseNet201. The findings showed that before and after utilizing approaches, picture augmentation schemes significantly affected the networks. The accuracy of MobileNetV2, which was originally 85.33 percent, was then enhanced to 96.88 percent. The accuracy of VGG19, which was 77.33 percent, was then enhanced to 95.31 percent, and DenseNet201, which was originally 82.66 percent, was then enhanced to 93.75 percent. The models' accuracy percentage engagement change is 13.53 percent, 23.25 percent, and 23.25 percent, respectively. Finally, the conclusion showed that applying data augmentation approaches improves performance, producing models far better than those trained from scratch.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 15 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Halabja
  • University of Human Development
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4387286857, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Deep Transfer Learning Networks for Brain Tumor Detection: The Effect of MRI Patient Image Augmentation Methods</dc:title><dc:creator>Peshraw Ahmed Abdalla</dc:creator><dc:creator>Abdalbasit Mohammed Qadir</dc:creator><dc:creator>Omed Jamal Rashid</dc:creator><dc:creator>Karwan Mahdi Hama Rawf</dc:creator><dc:creator>Ayub Othman Abdulrahman</dc:creator><dc:creator>Bashdar Abdalrahman Mohammed</dc:creator><dc:subject>brain tumor detection</dc:subject><dc:subject>magnetic resonance imaging</dc:subject><dc:subject>data augmentation</dc:subject><dc:subject>transfer learning</dc:subject><dc:subject>MobileNetV2</dc:subject><dc:subject>VGG19</dc:subject><dc:subject>DenseNet201</dc:subject><dc:subject>convolutional neural networks</dc:subject><dc:subject>medical image classification</dc:subject><dc:subject>small datasets</dc:subject><dc:description xml:lang="en">The exponential growth of deep learning networks has enabled us to handle difficult tasks, even in the complex field of medicine with small datasets. In the sphere of treatment, they are particularly significant. To identify brain tumors, this research examines how three deep learning networks are affected by conventional data augmentation methods, including MobileNetV2, VGG19, and DenseNet201. The findings showed that before and after utilizing approaches, picture augmentation schemes significantly affected the networks. The accuracy of MobileNetV2, which was originally 85.33 percent, was then enhanced to 96.88 percent. The accuracy of VGG19, which was 77.33 percent, was then enhanced to 95.31 percent, and DenseNet201, which was originally 82.66 percent, was then enhanced to 93.75 percent. The models' accuracy percentage engagement change is 13.53 percent, 23.25 percent, and 23.25 percent, respectively. Finally, the conclusion showed that applying data augmentation approaches improves performance, producing models far better than those trained from scratch.</dc:description><dc:publisher>UIN Raden Intan Lampung</dc:publisher><dc:date>2022-12-25</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.24042/ijecs.v2i2.14815</dc:identifier><dc:identifier>10.24042/ijecs.v2i2.14815</dc:identifier><dc:source>International Journal of Electronics and Communications Systems; Vol 2 No 2 (2022); 39-48</dc:source><dc:source>2798-2610</dc:source><dc:language>en</dc:language><dc:relation>http://ejournal.radenintan.ac.id/index.php/IJECS/article/download/14815/pdf</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>