Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Conductor minimum safe distance analysis: Application of a 20 kV medium voltage airline (SUTM) system

International Journal of Electronics and Communications Systems · Vol. 1 No. 1 (2021) · hlm. 17–23

DOI
10.24042/ijecs.v1i1.9215
ISSN
2798-2610
Terbit
2021-06-28
Penerbit
UIN Raden Intan Lampung
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Medium Voltage Air Line Conductor (SUTM) has a voltage of 20 kV. The SUTM network should have the criteria for electricity safety techniques, including minimum safety distances between the trees and the environment and the effectiveness of electricity distribution development. There are ten stages in the installation of the new SUTM 20 kV network. The results of the study concluded that the Conductor used in the planning of the 20 kV SUTM new network construction was AAACS - 150 mm2. The safe distance between the conductors and the conditions contained Billboards are more than 0.5 meters with a minimum height difference of ± 2.5 meters. Whereas the safe distance between the conductor and the tree is ± 0.5 meters, but the Medium Voltage Network Construction Standard for Electric Power must have a height difference of more than 2.5 meters. The distance between the conductor and billboards is> 0.5 meters, which does not complete the standard instructions.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 12 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Muhammadiyah Lampung
  • Institut Teknologi Nasional Yogyakarta
  • National Central University
  • UIN Sunan Ampel Surabaya
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rizqi PrastowoInstitut Teknologi Nasional Yogyakarta1
Sely Novita SariInstitut Teknologi Nasional Yogyakarta1
Rahmad JunaidiUIN Sunan Ampel Surabaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4387286857, pertama di-harvest 21 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Conductor minimum safe distance analysis: Application of a 20 kV medium voltage airline (SUTM) system</dc:title><dc:creator>Amir Machmud</dc:creator><dc:creator>Suranto Suranto</dc:creator><dc:creator>Hamimi Hamimi</dc:creator><dc:creator>Setyo Harmono</dc:creator><dc:subject>power distribution planning</dc:subject><dc:subject>electrical safety standards</dc:subject><dc:description xml:lang="en">Medium Voltage Air Line Conductor (SUTM) has a voltage of 20 kV. The SUTM network should have the criteria for electricity safety techniques, including minimum safety distances between the trees and the environment and the effectiveness of electricity distribution development. There are ten stages in the installation of the new SUTM 20 kV network. The results of the study concluded that the Conductor used in the planning of the 20 kV SUTM new network construction was AAACS - 150 mm2. The safe distance between the conductors and the conditions contained Billboards are more than 0.5 meters with a minimum height difference of ± 2.5 meters. Whereas the safe distance between the conductor and the tree is ± 0.5 meters, but the Medium Voltage Network Construction Standard for Electric Power must have a height difference of more than 2.5 meters. The distance between the conductor and billboards is&gt; 0.5 meters, which does not complete the standard instructions.</dc:description><dc:publisher>UIN Raden Intan Lampung</dc:publisher><dc:date>2021-06-28</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.24042/ijecs.v1i1.9215</dc:identifier><dc:identifier>10.24042/ijecs.v1i1.9215</dc:identifier><dc:source>International Journal of Electronics and Communications Systems; Vol 1 No 1 (2021); 17-23</dc:source><dc:source>2798-2610</dc:source><dc:language>en</dc:language><dc:relation>http://ejournal.radenintan.ac.id/index.php/IJECS/article/download/9215/pdf</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>