Akses terbuka
Jurnal
SINTA 1
Wearable antenna for non-invasive human arm bone fracture monitoring system
Mohd Saiful Riza Bashri Noor Amalina Ramli Abang Muhammad Sufi Abang Madehan
Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 6 (2026) · hlm. 4924–4934
ISSN 2089-3191, 2302-9285
Terbit 2026-12-01
Penerbit Institute of Advanced Engineering and Science (IAES)
Bahasa en
Abstrak
This paper presents a flexible wearable monopole antenna for non-invasive monitoring of human arm bone fracture healing. The antenna is fabricated on a polyethylene terephthalate (PET) substrate and is intended for integration into an arm cast for continuous monitoring during healing. With dimensions of 77 mm×53 mm×0.2 mm, the antenna operates from 1.7 to 2.6 GHz in free space and exhibits resonance changes when placed on a human arm phantom. Bone healing is assessed through changes in the antenna reflection coefficient caused by variations in the dielectric properties around the fracture site. Experimental measurements show resonance at approximately 1.84 GHz without blood, 1.88 GHz with 10 ml of blood, and 1.82 GHz with 20 ml of blood, demonstrating sensitivity to changes associated with the healing process. The simulated specific absorption rate is 0.0452 W/kg at 1 mW transmitted power, within accepted safety limits. The agreement between simulation and measurement supports the feasibility of the proposed compact, low-cost, and non-invasive monitoring approach.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Wearable antenna for non-invasive human arm bone fracture monitoring system</dc:title><dc:creator>Mohd Saiful Riza Bashri</dc:creator><dc:creator>Noor Amalina Ramli</dc:creator><dc:creator>Abang Muhammad Sufi Abang Madehan</dc:creator><dc:subject>wearable antennas</dc:subject><dc:subject>monopole antenna</dc:subject><dc:subject>flexible antenna</dc:subject><dc:subject>polyethylene terephthalate substrate</dc:subject><dc:subject>dielectric properties</dc:subject><dc:subject>blood content</dc:subject><dc:subject>reflection coefficient</dc:subject><dc:subject>specific absorption rate</dc:subject><dc:subject>non-invasive monitoring</dc:subject><dc:description xml:lang="en">This paper presents a flexible wearable monopole antenna for non-invasive monitoring of human arm bone fracture healing. The antenna is fabricated on a polyethylene terephthalate (PET) substrate and is intended for integration into an arm cast for continuous monitoring during healing. With dimensions of 77 mm×53 mm×0.2 mm, the antenna operates from 1.7 to 2.6 GHz in free space and exhibits resonance changes when placed on a human arm phantom. Bone healing is assessed through changes in the antenna reflection coefficient caused by variations in the dielectric properties around the fracture site. Experimental measurements show resonance at approximately 1.84 GHz without blood, 1.88 GHz with 10 ml of blood, and 1.82 GHz with 20 ml of blood, demonstrating sensitivity to changes associated with the healing process. The simulated specific absorption rate is 0.0452 W/kg at 1 mW transmitted power, within accepted safety limits. The agreement between simulation and measurement supports the feasibility of the proposed compact, low-cost, and non-invasive monitoring approach.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i6.11622</dc:identifier><dc:identifier>10.11591/eei.v15i6.11622</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 6 (2026); 4924-4934</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/11622/5148</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Belum diperiksa
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 23 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
Sitasi artikel ini
APA 7
Bashri, M. S. R., Ramli, N. A., & Madehan, A. M. S. A. (2026). Wearable antenna for non-invasive human arm bone fracture monitoring system. Bulletin of Electrical Engineering and Informatics, 15(6), 4924–4934. https://doi.org/10.11591/eei.v15i6.11622
Salin
IEEE
M. S. R. Bashri, N. A. Ramli, and A. M. S. A. Madehan, “Wearable antenna for non-invasive human arm bone fracture monitoring system,” Bulletin of Electrical Engineering and Informatics, vol. 15, no. 6, pp. 4924–4934, 2026, doi: 10.11591/eei.v15i6.11622.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.