Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Photovoltaic-integrated system for electric vehicle charging in single-phase electrical grids

  • José M. Aller
  • Cristian Fernando León Zhagñay
  • Bruno Vinicio Ortiz Cárdenas

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 6 (2026) · hlm. 4863–4875

DOI
10.11591/eei.v15i6.12383
ISSN
2089-3191, 2302-9285
Terbit
2026-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This paper presents the modeling and analysis of a photovoltaic (PV)–based electric vehicle (EV) charging system integrated into a single-phase distribution grid. The complete system is implemented in the ATP–EMTP environment using the ATPDraw graphical interface, including PV generation with maximum power point tracking (MPPT)-controlled DC–DC conversion, a single-phase grid-connected inverter with sinusoidal pulse width modulation (SPWM), inductor capacitor inductor (LCL) filtering, and bidirectional power-flow capability. The distinctive contribution of this work is the integration of the complete conversion and control chain within a unified circuit-level ATP–EMTP/ATPDraw framework, while explicitly considering the double-frequency power oscillations inherent to single-phase grid interfaces. Unlike balanced three-phase operation, single-phase systems exhibit power oscillations at twice the grid frequency, which complicates controller tuning and power regulation. Coordinated active- and reactive-power regulation is therefore implemented using synchronized proportional integral (PI) controllers and a phase-locked loop (PLL) represented through ATPDraw MODELS blocks. Simulation results demonstrate stable operation under irradiance variations and effective power regulation. For active-power references of 1–2 kW, representative steady-state tracking errors remain below 0.7%, while the final 1 kW operating interval exhibits an average reactive-power estimate of approximately 21 var.

Kata kunci

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Photovoltaic-integrated system for electric vehicle charging in single-phase electrical grids</dc:title><dc:creator>José M. Aller</dc:creator><dc:creator>Cristian Fernando León Zhagñay</dc:creator><dc:creator>Bruno Vinicio Ortiz Cárdenas</dc:creator><dc:subject>maximum power point tracking</dc:subject><dc:subject>DC-DC converter</dc:subject><dc:subject>single-phase inverter</dc:subject><dc:subject>LCL filter</dc:subject><dc:subject>bidirectional power flow</dc:subject><dc:subject>active and reactive power control</dc:subject><dc:subject>phase-locked loop</dc:subject><dc:subject>irradiance variation</dc:subject><dc:description xml:lang="en">This paper presents the modeling and analysis of a photovoltaic (PV)–based electric vehicle (EV) charging system integrated into a single-phase distribution grid. The complete system is implemented in the ATP–EMTP environment using the ATPDraw graphical interface, including PV generation with maximum power point tracking (MPPT)-controlled DC–DC conversion, a single-phase grid-connected inverter with sinusoidal pulse width modulation (SPWM), inductor capacitor inductor (LCL) filtering, and bidirectional power-flow capability. The distinctive contribution of this work is the integration of the complete conversion and control chain within a unified circuit-level ATP–EMTP/ATPDraw framework, while explicitly considering the double-frequency power oscillations inherent to single-phase grid interfaces. Unlike balanced three-phase operation, single-phase systems exhibit power oscillations at twice the grid frequency, which complicates controller tuning and power regulation. Coordinated active- and reactive-power regulation is therefore implemented using synchronized proportional integral (PI) controllers and a phase-locked loop (PLL) represented through ATPDraw MODELS blocks. Simulation results demonstrate stable operation under irradiance variations and effective power regulation. For active-power references of 1–2 kW, representative steady-state tracking errors remain below 0.7%, while the final 1 kW operating interval exhibits an average reactive-power estimate of approximately 21 var.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i6.12383</dc:identifier><dc:identifier>10.11591/eei.v15i6.12383</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 6 (2026); 4863-4875</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/12383/5145</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>