Investigation of maximum molar point on green hydrogen production using power electronic converter

  • Ahmad Rosyid Idris
  • Faizal Arya Samman
  • Alamsyah Achmad
  • Musfirah Putri Lukman
  • Syamsumarlin Taha

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 6 (2026) · hlm. 4825–4836

DOI
10.11591/eei.v15i6.12094
ISSN
2089-3191, 2302-9285
Terbit
2026-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Green hydrogen production using photovoltaic (PV)-powered electrolysis is challenged by intermittent irradiance, which changes the electrical operating point of the electrolyzer. This study investigates the maximum molar point (MMP) as a hydrogen-oriented operating concept for a PV–buck–proton exchange membrane (PEM) electrolyzer system. A dual-loop proportional–integral (PI) controller regulates the electrolyzer voltage and current, while the MMP is identified separately through duty-cycle characterization. The final model uses one 1Soltech 1STH-220-P PV module and a 50 kHz buck converter. A two-stage duty-cycle sweep identifies a near-maximum hydrogen-production region at D=0.75–0.85, with approximately 2.53710-5 mol/s at 1,000 W/m². Under irradiance levels from 600 to 1,000 W/m², MMP-oriented operation increases mean hydrogen production by 20.66–73.91% relative to conventional perturb-and-observe (P&O) maximum power point tracking (MPPT). The average hydrogen-production rate increases from 1.4386×10-5 mol/s for MPPT to 2.2458×10-5 mol/s for MMP-oriented operation, corresponding to an average improvement of 55.88%, while the average coefficient of variation (CV) decreases from 0.830% to 0.081%. The results demonstrate the potential of shifting the optimization objective from PV power toward hydrogen production; adaptive online MMP tracking, temperature/degradation effects, and parameter-robustness analysis remain future work.

Kata kunci

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Investigation of maximum molar point on green hydrogen production using power electronic converter</dc:title><dc:creator>Ahmad Rosyid Idris</dc:creator><dc:creator>Faizal Arya Samman</dc:creator><dc:creator>Alamsyah Achmad</dc:creator><dc:creator>Musfirah Putri Lukman</dc:creator><dc:creator>Syamsumarlin Taha</dc:creator><dc:subject>green hydrogen production</dc:subject><dc:subject>photovoltaic electrolysis</dc:subject><dc:subject>proton exchange membrane electrolyzer</dc:subject><dc:subject>buck converter</dc:subject><dc:subject>maximum power point tracking</dc:subject><dc:subject>perturb and observe</dc:subject><dc:subject>hydrogen production rate</dc:subject><dc:subject>coefficient of variation</dc:subject><dc:description xml:lang="en">Green hydrogen production using photovoltaic (PV)-powered electrolysis is challenged by intermittent irradiance, which changes the electrical operating point of the electrolyzer. This study investigates the maximum molar point (MMP) as a hydrogen-oriented operating concept for a PV–buck–proton exchange membrane (PEM) electrolyzer system. A dual-loop proportional–integral (PI) controller regulates the electrolyzer voltage and current, while the MMP is identified separately through duty-cycle characterization. The final model uses one 1Soltech 1STH-220-P PV module and a 50 kHz buck converter. A two-stage duty-cycle sweep identifies a near-maximum hydrogen-production region at D=0.75–0.85, with approximately 2.53710-5 mol/s at 1,000 W/m². Under irradiance levels from 600 to 1,000 W/m², MMP-oriented operation increases mean hydrogen production by 20.66–73.91% relative to conventional perturb-and-observe (P&amp;O) maximum power point tracking (MPPT). The average hydrogen-production rate increases from 1.4386×10-5 mol/s for MPPT to 2.2458×10-5 mol/s for MMP-oriented operation, corresponding to an average improvement of 55.88%, while the average coefficient of variation (CV) decreases from 0.830% to 0.081%. The results demonstrate the potential of shifting the optimization objective from PV power toward hydrogen production; adaptive online MMP tracking, temperature/degradation effects, and parameter-robustness analysis remain future work.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i6.12094</dc:identifier><dc:identifier>10.11591/eei.v15i6.12094</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 6 (2026); 4825-4836</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/12094/5073</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>