Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Interpretable vision transformer with dual loss and Grad-CAM for iris-based early lung damage detection

  • Hung Dac Ho
  • Van-Len Vo
  • Trong Thua Huynh

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 6 (2026) · hlm. 5033–5045

DOI
10.11591/eei.v15i6.13484
ISSN
2089-3191, 2302-9285
Terbit
2026-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Iridology infers organ health from the appearance of the iris; its clinical record is contested, but iris photography combined with learned representations allows the underlying question-whether disease-correlated structure exists in iris images-to be tested against external clinical labels. We present an interpretable framework combining a vision transformer (ViT) trained with a dual cross-entropy and triplet objective with a quantitative evaluation of its gradient-weighted class activation mapping (Grad-CAM) explanations, for binary classification of lung damage from iris images labelled by independent clinical diagnosis. On a held-out set of 356 single-participant images the model reaches 0.9249 precision and 0.9242 recall, matching a ResNet-50 baseline and a single-loss ViT to within two images at 21% lower datacentre latency. The principal contribution is the measurement of interpretability rather than its assertion: true-positive saliency maps are causally faithful, reproducible and class-discriminative, while their 0.9315 overlap with false-positive maps bounds what they may be taken to mean - they show where the model finds positive evidence, not where pathology is. We additionally audit acquisition confounding and find that image-quality statistics alone separate the classes at area under the receiver operating characteristic curve (AUROC), establishing a floor that iris-based screening studies should report and that, to our knowledge.

Kata kunci

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Interpretable vision transformer with dual loss and Grad-CAM for iris-based early lung damage detection</dc:title><dc:creator>Hung Dac Ho</dc:creator><dc:creator>Van-Len Vo</dc:creator><dc:creator>Trong Thua Huynh</dc:creator><dc:subject>iridology</dc:subject><dc:subject>iris images</dc:subject><dc:subject>vision transformer</dc:subject><dc:subject>triplet loss</dc:subject><dc:subject>cross-entropy loss</dc:subject><dc:subject>Grad-CAM</dc:subject><dc:subject>interpretability</dc:subject><dc:subject>saliency maps</dc:subject><dc:subject>image quality</dc:subject><dc:subject>binary classification</dc:subject><dc:description xml:lang="en">Iridology infers organ health from the appearance of the iris; its clinical record is contested, but iris photography combined with learned representations allows the underlying question-whether disease-correlated structure exists in iris images-to be tested against external clinical labels. We present an interpretable framework combining a vision transformer (ViT) trained with a dual cross-entropy and triplet objective with a quantitative evaluation of its gradient-weighted class activation mapping (Grad-CAM) explanations, for binary classification of lung damage from iris images labelled by independent clinical diagnosis. On a held-out set of 356 single-participant images the model reaches 0.9249 precision and 0.9242 recall, matching a ResNet-50 baseline and a single-loss ViT to within two images at 21% lower datacentre latency. The principal contribution is the measurement of interpretability rather than its assertion: true-positive saliency maps are causally faithful, reproducible and class-discriminative, while their 0.9315 overlap with false-positive maps bounds what they may be taken to mean - they show where the model finds positive evidence, not where pathology is. We additionally audit acquisition confounding and find that image-quality statistics alone separate the classes at area under the receiver operating characteristic curve (AUROC), establishing a floor that iris-based screening studies should report and that, to our knowledge.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i6.13484</dc:identifier><dc:identifier>10.11591/eei.v15i6.13484</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 6 (2026); 5033-5045</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/13484/5091</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>