Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Agentic AI-driven framework for transformer fault prediction, diagnosis, and autonomous rectification planning

  • P. Lakshminarayana
  • Robbi Rahim
  • M. Kavitha
  • A. V. Prabu

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 6 (2026) · hlm. 5474–5485

DOI
10.11591/eei.v15i6.13905
ISSN
2089-3191, 2302-9285
Terbit
2026-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Fault management in transformers is critical in ensuring the reliability in the power system and avoiding equipment failures. Nevertheless, the traditional monitoring methods tend to deal with fault prediction, diagnosis and corrective action independently and do not provide a combined decision making and post-action assessment. In this paper, an agentic artificial intelligence (AI) system is presented that combines transformer fault prediction, multi-class diagnosis, and autonomous rectification planning in a closed-loop system. An electrical, thermal and dissolved-gas variables reproducible synthetic dataset that includes 5,000 balanced operating records is created. Extra trees regressor is used to estimate the probability of fault and a random forest model is used to classify fault types. An expert-crafted policy based on a rule and operational and safety constraints is based on an automatic choice of corrective actions, without reinforcement learning (RL). A train-test split (80:20) and a five-fold cross-validation are used. In the held-out test set, the predictor results in MAE=0.0205, RMSE=0.0271, and R2=0.9881 and the diagnosis model results in 97.63% accuracy and macro F1=0.9762. The rule-based rectification mechanism generates an average simulated risk reduction (RR) of 72.67 with a range of 65.15-78.20 between the fault scenarios which shows integrated prediction, diagnosis, constrained action selection and feedback evaluation.

Kata kunci

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Agentic AI-driven framework for transformer fault prediction, diagnosis, and autonomous rectification planning</dc:title><dc:creator>P. Lakshminarayana</dc:creator><dc:creator>Robbi Rahim</dc:creator><dc:creator>M. Kavitha</dc:creator><dc:creator>A. V. Prabu</dc:creator><dc:subject>transformer fault prediction</dc:subject><dc:subject>fault diagnosis</dc:subject><dc:subject>agentic AI</dc:subject><dc:subject>closed-loop decision-making</dc:subject><dc:subject>dissolved gas analysis</dc:subject><dc:subject>temperature monitoring</dc:subject><dc:subject>synthetic dataset</dc:subject><dc:subject>extra trees regression</dc:subject><dc:subject>random forest classification</dc:subject><dc:subject>risk mitigation</dc:subject><dc:subject>power system reliability</dc:subject><dc:description xml:lang="en">Fault management in transformers is critical in ensuring the reliability in the power system and avoiding equipment failures. Nevertheless, the traditional monitoring methods tend to deal with fault prediction, diagnosis and corrective action independently and do not provide a combined decision making and post-action assessment. In this paper, an agentic artificial intelligence (AI) system is presented that combines transformer fault prediction, multi-class diagnosis, and autonomous rectification planning in a closed-loop system. An electrical, thermal and dissolved-gas variables reproducible synthetic dataset that includes 5,000 balanced operating records is created. Extra trees regressor is used to estimate the probability of fault and a random forest model is used to classify fault types. An expert-crafted policy based on a rule and operational and safety constraints is based on an automatic choice of corrective actions, without reinforcement learning (RL). A train-test split (80:20) and a five-fold cross-validation are used. In the held-out test set, the predictor results in MAE=0.0205, RMSE=0.0271, and R2=0.9881 and the diagnosis model results in 97.63% accuracy and macro F1=0.9762. The rule-based rectification mechanism generates an average simulated risk reduction (RR) of 72.67 with a range of 65.15-78.20 between the fault scenarios which shows integrated prediction, diagnosis, constrained action selection and feedback evaluation.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i6.13905</dc:identifier><dc:identifier>10.11591/eei.v15i6.13905</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 6 (2026); 5474-5485</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/13905/5125</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>