Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Artificial intelligence–based design of proportional-integral controllers for active power filters in railway electrification

  • Chakrit Panpean
  • Chirdpong Deelertpaiboon
  • Jeerawan Homjan
  • Ittiphong Yongyee
  • Warunee Srisongkram
  • Napat Watjanatepin

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 6 (2026) · hlm. 4850–4862

DOI
10.11591/eei.v15i6.13589
ISSN
2089-3191, 2302-9285
Terbit
2026-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Conventional tuning of proportional–integral (PI) controllers for active power filters (APFs) cannot ensure optimal improvement of power quality performance in electric railway applications. This research introduces an artificial intelligence (AI) methodology for the design of a PI controller in electric railway systems. The adaptive Tabu search (ATS) algorithm is utilized to search for the optimal parameters of a compensating current controller and direct current (DC) bus voltage controller, with the aim of concurrently optimizing harmonic current suppression, current imbalance compensation, and power factor (PF) correction. The efficacy of the proposed method is assessed via hardware-in-the-loop (HIL) simulation. Experimental results validate that the compensating current controller and DC bus voltage controller, designed using the ATS algorithm, demonstrably improve harmonic mitigation performance. This enhancement is substantiated through the power quality index, specifically the percentage of total harmonic distortion of current (%THDi), percentage of current unbalance factor (%CUF), and the PF compliance with the IEEE standard. Consequently, the proposed approach offers a practical and effective solution for elevating power quality within electric railway systems.

Kata kunci

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Artificial intelligence–based design of proportional-integral controllers for active power filters in railway electrification</dc:title><dc:creator>Chakrit Panpean</dc:creator><dc:creator>Chirdpong Deelertpaiboon</dc:creator><dc:creator>Jeerawan Homjan</dc:creator><dc:creator>Ittiphong Yongyee</dc:creator><dc:creator>Warunee Srisongkram</dc:creator><dc:creator>Napat Watjanatepin</dc:creator><dc:subject>active power filter</dc:subject><dc:subject>railway electrification</dc:subject><dc:subject>adaptive tabu search</dc:subject><dc:subject>harmonic current suppression</dc:subject><dc:subject>power factor correction</dc:subject><dc:subject>DC bus voltage regulation</dc:subject><dc:subject>power quality</dc:subject><dc:subject>total harmonic distortion</dc:subject><dc:subject>hardware-in-the-loop</dc:subject><dc:description xml:lang="en">Conventional tuning of proportional–integral (PI) controllers for active power filters (APFs) cannot ensure optimal improvement of power quality performance in electric railway applications. This research introduces an artificial intelligence (AI) methodology for the design of a PI controller in electric railway systems. The adaptive Tabu search (ATS) algorithm is utilized to search for the optimal parameters of a compensating current controller and direct current (DC) bus voltage controller, with the aim of concurrently optimizing harmonic current suppression, current imbalance compensation, and power factor (PF) correction. The efficacy of the proposed method is assessed via hardware-in-the-loop (HIL) simulation. Experimental results validate that the compensating current controller and DC bus voltage controller, designed using the ATS algorithm, demonstrably improve harmonic mitigation performance. This enhancement is substantiated through the power quality index, specifically the percentage of total harmonic distortion of current (%THDi), percentage of current unbalance factor (%CUF), and the PF compliance with the IEEE standard. Consequently, the proposed approach offers a practical and effective solution for elevating power quality within electric railway systems.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i6.13589</dc:identifier><dc:identifier>10.11591/eei.v15i6.13589</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 6 (2026); 4850-4862</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/13589/5076</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>