Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Unified mobile framework for electrocardiogram-based myocardial infarction detection and arrhythmia classification

  • Sameer Ahmad Hasan
  • Samer J. Alabed
  • Talal Ayyoub
  • Abdullah Shahin

Bulletin of Electrical Engineering and Informatics · Vol. 15 No. 6 (2026) · hlm. 5068–5078

DOI
10.11591/eei.v15i6.11689
ISSN
2089-3191, 2302-9285
Terbit
2026-12-01
Penerbit
Institute of Advanced Engineering and Science (IAES)
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Cardiovascular diseases (CVDs), particularly myocardial infarction (MI) and arrhythmias, require timely and accurate computational support for screening and follow-up. This study presents a unified internet of things (IoT)-enabled electrocardiogram (ECG) framework for mobile MI detection and multiclass arrhythmia classification. The framework integrates ECG preprocessing using biorthogonal and median filtering, machine learning (ML)-based interpretation, and mobile application delivery for prompt diagnostic feedback. The main contribution of this work is the integration of MI detection and multiclass arrhythmia classification within a single mobile-health workflow. The best random forest (RF) model achieved 96.89% accuracy for MI detection. For arrhythmia classification, the selected RF model achieved 89.59% accuracy on the held-out test set. These findings support the potential of the proposed framework as a mobile decision-support system for ECG interpretation and remote follow-up. Because evaluation was performed on row-level samples rather than patient-disjoint data, the reported results should be interpreted as within-dataset decision-support performance. Overall, the framework provides a practical link between ECG interpretation and mobile-health delivery while supporting further validation in real-world deployment settings.

Kata kunci

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2765016208, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Unified mobile framework for electrocardiogram-based myocardial infarction detection and arrhythmia classification</dc:title><dc:creator>Sameer Ahmad Hasan</dc:creator><dc:creator>Samer J. Alabed</dc:creator><dc:creator>Talal Ayyoub</dc:creator><dc:creator>Abdullah Shahin</dc:creator><dc:subject>myocardial infarction detection</dc:subject><dc:subject>arrhythmia classification</dc:subject><dc:subject>electrocardiogram</dc:subject><dc:subject>mobile health</dc:subject><dc:subject>Internet of Things</dc:subject><dc:subject>random forest</dc:subject><dc:subject>median filter</dc:subject><dc:subject>ECG signal preprocessing</dc:subject><dc:subject>decision support system</dc:subject><dc:subject>remote patient monitoring</dc:subject><dc:description xml:lang="en">Cardiovascular diseases (CVDs), particularly myocardial infarction (MI) and arrhythmias, require timely and accurate computational support for screening and follow-up. This study presents a unified internet of things (IoT)-enabled electrocardiogram (ECG) framework for mobile MI detection and multiclass arrhythmia classification. The framework integrates ECG preprocessing using biorthogonal and median filtering, machine learning (ML)-based interpretation, and mobile application delivery for prompt diagnostic feedback. The main contribution of this work is the integration of MI detection and multiclass arrhythmia classification within a single mobile-health workflow. The best random forest (RF) model achieved 96.89% accuracy for MI detection. For arrhythmia classification, the selected RF model achieved 89.59% accuracy on the held-out test set. These findings support the potential of the proposed framework as a mobile decision-support system for ECG interpretation and remote follow-up. Because evaluation was performed on row-level samples rather than patient-disjoint data, the reported results should be interpreted as within-dataset decision-support performance. Overall, the framework provides a practical link between ECG interpretation and mobile-health delivery while supporting further validation in real-world deployment settings.</dc:description><dc:publisher>Institute of Advanced Engineering and Science (IAES)</dc:publisher><dc:date>2026-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/eei.v15i6.11689</dc:identifier><dc:identifier>10.11591/eei.v15i6.11689</dc:identifier><dc:source>Bulletin of Electrical Engineering and Informatics; Vol 15 No 6 (2026); 5068-5078</dc:source><dc:source>2089-3191</dc:source><dc:source>2302-9285</dc:source><dc:language>en</dc:language><dc:relation>https://beei.org/index.php/EEI/article/download/11689/5153</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>