THERMAL EFFICIENCY ANALYSIS ON THE STEAM POWER PLANT IN NII TANASA BY USING A TWO-SEMESTER DIRECT METHOD WITH A CAPACITY OF 2 x 10 MW

Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali) · Vol. 4 No. 3 (2019)

DOI
10.33772/jfe.v4i3.10259
ISSN
2502-5562
Published
2019-09-16
Publisher
Universitas Halu Oleo
License
creativecommons.org/licenses/by/4.0

Abstract

The thermal efficiency of a steam power plant is very important to know because it involves the initial input of a steam supply that will turn a turbine. This is done to analyze how much thermal efficiency is used in the generation system, so that it can be seen the continued use of the generation system, which is influenced by the value of the Net Plant Heat rate (NPHR). The purpose of this study is to analyze the thermal efficiency of the steam power plant. The method used is the direct method, using a two-semester system namely: semester one (January-June) and then taking months that represent or tend to be stable data, as well as the second semester (July-December). Analysis results In the case study of a steam power plant in Nii Tanasa, the average thermal efficiency value was 17.09%, while in the second semester the analysis of thermal efficiency values was obtained an average value of 15.54%. This value still tends to be low at a capacity of 100 MW, so it is necessary to evaluate the value of the Net plant heat rate (NPHR), especially the type of fuel used, because the calculation on thermal efficiency is strongly influenced by that value. Key words: NPHR, Efficiency, Semester, steam, thermal

Collaboration network of the authors

40 authors · 230 co-authorship links · 3 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Halu Oleo
  • Universitas Syiah Kuala
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Samhuddin SamhuddinAffiliation unknown36
Budiman SudiaAffiliation unknown31
Salimin SaliminAffiliation unknown29
Yuspian GunawanAffiliation unknown25
Prinob AksarUniversitas Halu Oleo20
Sudarsono SudarsonoAffiliation unknown15
Nanang EndriatnoAffiliation unknown14
Lukas Kano MangallaUniversitas Halu Oleo13
La HasanuddinAffiliation unknown12
Muhammad HasbiUniversitas Syiah Kuala10
Muhammad SudiaAffiliation unknown6
Salim SalimUniversitas Halu Oleo6
La Ode Ahmad BarataAffiliation unknown6
La MasiAffiliation unknown5
Mustamin AnggoUniversitas Halu Oleo5
Raden Rinova SisworoUniversitas Halu Oleo5
Fahinu FahinuAffiliation unknown4
Indrayati GaluguAffiliation unknown4
Jenny DellyAffiliation unknown4
La ArapuAffiliation unknown3
Rahmad PrajonoAffiliation unknown3
Edi CahyonoUniversitas Halu Oleo3
Anwar BeyAffiliation unknown3
Luther PagilingAffiliation unknown3
Suhar SuharAffiliation unknown2
Jafar JafarAffiliation unknown2
Kodirun KodirunUniversitas Halu Oleo2
La Ode Ahmad JazuliAffiliation unknown2
Mohamad SalamAffiliation unknown2
Ruslan RuslanAffiliation unknown2
Sahabuddin HayUniversitas Halu Oleo2

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs.uho.ac.id/index.php/JFE/oai, first harvested 31 Okt 2026, last seen 31 Okt 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">THERMAL EFFICIENCY ANALYSIS ON THE STEAM POWER PLANT IN NII TANASA BY USING A TWO-SEMESTER DIRECT METHOD WITH A CAPACITY OF 2 x 10 MW</dc:title>
	<dc:creator>Hasanudin, La</dc:creator>
	<dc:creator>Saefuddin, Laode</dc:creator>
	<dc:creator>Lolok, Agustinus</dc:creator>
	<dc:creator>Balaka, Ridway</dc:creator>
	<dc:creator>Adnal, Adnal</dc:creator>
	<dc:creator>Imran, Al Ichlas</dc:creator>
	<dc:creator>Kadir, Kadir</dc:creator>
	<dc:creator>Kadir, Abd</dc:creator>
	<dc:creator>Aminur, Aminur</dc:creator>
	<dc:description xml:lang="en-US">The thermal efficiency of a steam power plant is very important to know because it involves the initial input of a steam supply that will turn a turbine. This is done to analyze how much thermal efficiency is used in the generation system, so that it can be seen the continued use of the generation system, which is influenced by the value of the Net Plant Heat rate (NPHR). The purpose of this study is to analyze the thermal efficiency of the steam power plant. The method used is the direct method, using a two-semester system namely: semester one (January-June) and then taking months that represent or tend to be stable data, as well as the second semester (July-December). Analysis results In the case study of a steam power plant in Nii Tanasa, the average thermal efficiency value was 17.09%, while in the second semester the analysis of thermal efficiency values was obtained an average value of 15.54%. This value still tends to be low at a capacity of 100 MW, so it is necessary to evaluate the value of the Net plant heat rate (NPHR), especially the type of fuel used, because the calculation on thermal efficiency is strongly influenced by that value. Key words: NPHR, Efficiency, Semester, steam, thermal</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Halu Oleo</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2019-09-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:identifier>https://ojs.uho.ac.id/index.php/JFE/article/view/10259</dc:identifier>
	<dc:identifier>10.33772/jfe.v4i3.10259</dc:identifier>
	<dc:source xml:lang="en-US">Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali); Vol 4, No 3 (2019): Jurnal Elektroda Vol 4 No 3; PDF</dc:source>
	<dc:source>2502-5562</dc:source>
	<dc:source>10.33772/jfe.v4i3</dc:source>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 La Hasanudin, Laode Saefuddin, Agustinus Lolok, Ridway Balaka, Adnal Adnal, Al Ichlas Imran, Kadir Kadir, Abd Kadir, Aminur Aminur</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>