Kajian Dampak Ketidaknormalan Meter Elektronik Pada Sistem Automatic Meter Reading Pada Pelanggan Tegangan Rendah
Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali) · Vol. 6 No. 2 (2021) · hlm. 105–108
ISSN 2502-5562
Terbit 2021-06-30
Penerbit Universitas Halu Oleo
Bahasa eng
Abstrak
PT. PLN (Persero) as an lsitrik energy provider has the task of checking and measuring the use of electricity used by customers. In this case of course requires technology to be able to read how much electrical energy is used, one of the technologies used is Automatic Meter Reading (AMR). The use of Automatic Meter Reading (AMR) system includes monitoring, recording the stand meter then the data can be displayed in the form of a report with data software used management. Electronic meters using AMR systems can be used as a detection tool against irregularities from troubled customers. The readings obtained from AMR are known to the customer's usage, moments before the maintenance error and after. So that it can accurately detect customers who occur maintenance errors and customers and PLN both know the amount of uncollectible kWh, so far the nursing has been impaired by maintenance errors from the beginning of the tide. Based on existing data AMR should not be worth kWh value, but with the error of maintenance in phase S kWh measurable import that will be calculated to obtain a follow-up bill. The result obtained is true there is an inverted phase, it is shown in the fasor diagram where the angle of phase S which was originally 168.30 to 14.40. So that in the stand meter becomes minus the impact due to the mistake of maintenance obtained follow-up bill is 41538.8 kWh equivalent to Rp. 60.949.050,- after calculation. It shows the impact that occurs due to the mismanagement of the follow-up bill that must be borne
Jaringan kolaborasi para penulis
5 penulis ·
8 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Institut Teknologi PLN Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://ojs.uho.ac.id/index.php/JFE/oai, pertama di-harvest 31 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Kajian Dampak Ketidaknormalan Meter Elektronik Pada Sistem Automatic Meter Reading Pada Pelanggan Tegangan Rendah</dc:title>
<dc:creator>Samsurizal, Samsurizal</dc:creator>
<dc:creator>Siagian, Faber Agustinus G</dc:creator>
<dc:creator>Makkulau, Andi</dc:creator>
<dc:subject xml:lang="en-US">Automatic Meter Reading, Electronic Meter, Observation, Follow-up Bill</dc:subject>
<dc:description xml:lang="en-US">PT. PLN (Persero) as an lsitrik energy provider has the task of checking and measuring the use of electricity used by customers. In this case of course requires technology to be able to read how much electrical energy is used, one of the technologies used is Automatic Meter Reading (AMR). The use of Automatic Meter Reading (AMR) system includes monitoring, recording the stand meter then the data can be displayed in the form of a report with data software used management. Electronic meters using AMR systems can be used as a detection tool against irregularities from troubled customers. The readings obtained from AMR are known to the customer's usage, moments before the maintenance error and after. So that it can accurately detect customers who occur maintenance errors and customers and PLN both know the amount of uncollectible kWh, so far the nursing has been impaired by maintenance errors from the beginning of the tide. Based on existing data AMR should not be worth kWh value, but with the error of maintenance in phase S kWh measurable import that will be calculated to obtain a follow-up bill. The result obtained is true there is an inverted phase, it is shown in the fasor diagram where the angle of phase S which was originally 168.30 to 14.40. So that in the stand meter becomes minus the impact due to the mistake of maintenance obtained follow-up bill is 41538.8 kWh equivalent to Rp. 60.949.050,- after calculation. It shows the impact that occurs due to the mismanagement of the follow-up bill that must be borne</dc:description>
<dc:publisher xml:lang="en-US">Universitas Halu Oleo</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2021-06-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ojs.uho.ac.id/index.php/JFE/article/view/17925</dc:identifier>
<dc:identifier>10.33772/jfe.v6i2.17925</dc:identifier>
<dc:source xml:lang="en-US">Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali); Vol 6, No 2 (2021): Jurnal Elektroda Vol 6 No 2; 105-108</dc:source>
<dc:source>2502-5562</dc:source>
<dc:source>10.33772/jfe.v6i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ojs.uho.ac.id/index.php/JFE/article/view/17925/pdf</dc:relation>
<dc:relation>https://ojs.uho.ac.id/index.php/JFE/article/downloadSuppFile/17925/2780</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Samsurizal Samsurizal</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 7 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Samsurizal, S., Siagian, F. A. G., & Makkulau, A. (2021). Kajian Dampak Ketidaknormalan Meter Elektronik Pada Sistem Automatic Meter Reading Pada Pelanggan Tegangan Rendah. Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali), 6(2), 105–108. https://doi.org/10.33772/jfe.v6i2.17925
Salin
IEEE
S. Samsurizal, F. A. G. Siagian, and A. Makkulau, “Kajian Dampak Ketidaknormalan Meter Elektronik Pada Sistem Automatic Meter Reading Pada Pelanggan Tegangan Rendah,” Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali), vol. 6, no. 2, pp. 105–108, 2021, doi: 10.33772/jfe.v6i2.17925.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.