Melola Discovery

← Melola Discovery

Jurnal

Analisa Pengaruh Excess Air Terhadap Efisiensi Pembakaran Boiler Jenis Pulverizer Coal 230 T/H

Enthalpy : Jurnal Ilmiah Mahasiswa Teknik Mesin · Vol. 6 No. 3 (2021) · pp. 114–119

DOI
10.55679/enthalpy.v6i3.20979
ISSN
2502-8944
Published
2021-10-07
Publisher
Teknik Mesin Universitas Halu Oleo
Language
eng

Abstract

To save on coal consumption in PLTU (Steam Power Plant), it is necessary to increase boiler efficiency. The factors that can affect boiler efficiency include: flue gas temperature, fuel specification, excess air, ambient temperature, radiation and convection losses. By changing the value of excess air in this case the percentage of oxygen (4% to 4.5%) will affect the efficiency of the boiler. Changing the value of excess air also results in a change in the electrical power used by the auxiliary system in the boiler. Calculation of boiler efficiency with the direct method by testing 2 times on each oxygen percentage value of 4% and 4.5. Efficiency increased 0.94%, from 80.76% to 81.7% in test 1 and increased 1.02%, from 90.81% to 91.83% in test II. The power usage increased by 27.959 Kw in the 1st test and increased to 26.663 Kw in the test II.Kata kunci: Boiler, efficiency, excess air, PLTU

Collaboration network of the authors

40 authors · 179 co-authorship links · 7 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universitas Halu Oleo
  • Universitas Syiah Kuala
  • National Research and Innovation Agency
  • Universitas Islam Negeri Mahmud Yunus Batusangkar
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Sudarsono SudarsonoAffiliation unknown9
Prinob AksarUniversitas Halu Oleo7
Aminur AminurUniversitas Halu Oleo6
Budiman SudiaAffiliation unknown6
Yuspian GunawanAffiliation unknown5
Kadir KadirAffiliation unknown5
Al Ichlas ImranAffiliation unknown5
Abd KadirUniversitas Halu Oleo4
Salimin SaliminAffiliation unknown4
Ridway BalakaAffiliation unknown3
Jenny DellyAffiliation unknown3
Aditya RachmanAffiliation unknown3
Samhuddin SamhuddinAffiliation unknown3
La Ode Ahmad BarataAffiliation unknown2
Ardian SyahputraAffiliation unknown1
Ardian SyahputraUniversitas Syiah Kuala1
Usman UsmanUniversitas Syiah Kuala1
Erni MaidiyahUniversitas Syiah Kuala1
Irma NurjannahAffiliation unknown1
Luther PagilingAffiliation unknown1
Ld.M.Golok JayaAffiliation unknown1
Lukas Kano MangalaAffiliation unknown1
Asar AsarAffiliation unknown1
Rachmad SughiandiAffiliation unknown1
Bayu Hari AnggaraAffiliation unknown1
Andi YantoAffiliation unknown1
Andi Tri SetiawanAffiliation unknown1
laode MamurAffiliation unknown1
Prinob AskarAffiliation unknown1
Muhammad IkhsanAffiliation unknown1
Al Zenius Al ZeniusAffiliation unknown1
Darsono DarsonoNational Research and Innovation Agency1
Samidun SamidunAffiliation unknown1
Irwan IrwanUniversitas Islam Negeri Mahmud Yunus Batusangkar1
La HasanudinUniversitas Halu Oleo1
Raden Rinova SisworoUniversitas Halu Oleo1
Marwin MarwinAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ojs.uho.ac.id/index.php/ENTHALPY/oai, first harvested 31 Okt 2026, last seen 1 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analisa Pengaruh Excess Air Terhadap Efisiensi Pembakaran Boiler Jenis Pulverizer Coal 230 T/H</dc:title>
	<dc:creator>Muholad, Wildan</dc:creator>
	<dc:creator>Hasbi, Muhammad</dc:creator>
	<dc:creator>Endriatno, Nanang</dc:creator>
	<dc:description xml:lang="en-US">To save on coal consumption in PLTU (Steam Power Plant), it is necessary to increase boiler efficiency. The factors that can affect boiler efficiency include: flue gas temperature, fuel specification, excess air, ambient temperature, radiation and convection losses. By changing the value of excess air in this case the percentage of oxygen (4% to 4.5%) will affect the efficiency of the boiler. Changing the value of excess air also results in a change in the electrical power used by the auxiliary system in the boiler. Calculation of boiler efficiency with the direct method by testing 2 times on each oxygen percentage value of 4% and 4.5. Efficiency increased 0.94%, from 80.76% to 81.7% in test 1 and increased 1.02%, from 90.81% to 91.83% in test II. The power usage increased by 27.959 Kw in the 1st test and increased to 26.663 Kw in the test II.Kata kunci: Boiler, efficiency, excess air, PLTU</dc:description>
	<dc:publisher xml:lang="en-US">Teknik Mesin Universitas Halu Oleo</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-10-07</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs.uho.ac.id/index.php/ENTHALPY/article/view/20979</dc:identifier>
	<dc:identifier>10.55679/enthalpy.v6i3.20979</dc:identifier>
	<dc:source xml:lang="en-US">Enthalpy : Jurnal Ilmiah Mahasiswa Teknik Mesin; Vol 6, No 3 (2021): Enthalpy: Jurnal Ilmiah Mahasiswa Teknik Mesin; 114-119</dc:source>
	<dc:source>2502-8944</dc:source>
	<dc:source>10.55679/enthalpy.v6i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs.uho.ac.id/index.php/ENTHALPY/article/view/20979/13004</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 ENTHALPY</dc:rights>
</oai_dc:dc>