PEMODELAN DAN SIMULASI SKEMA PELEPASAN BEBAN DENGAN RELE FREKUENSI RENDAH SISTEM KELISTRIKAN DI PT. PLN (PERSERO) KOTA KENDARI

Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali) · Vol. 5 No. 1 (2020)

DOI
10.33772/jfe.v5i1.12334
ISSN
2502-5562
Terbit
2020-02-17
Penerbit
Universitas Halu Oleo
Lisensi
creativecommons.org/licenses/by/4.0

Abstrak

The deviation of the frequency of a power system from its nominal value is a reflection of the mismatch between generation and load. Such deviation are serious and must be monitored and controlled very closely. One major impact of operation outside a narrow range around the nominal frequency is that generators can demaged. To avoid this, manufacturers set time interval limits for under-frequency operation and when such limits are exceeded, the generator trips. Howeever, unless generator tripping is coordinated with some accompanying load shedding, the system inablitiy to supply its load can be exacerbated resulting in an even worse frequency deviation.Under-frequency load shedding (UFLS) is designed to protect the power system from event leading to a sudden drop in system frequency, when the primary frequency regulation built into the generation system is not enough to bring the frequency back to nominal. Under-frequency load shedding disconnect blocks of load when the frequency drop below given threshold. This study aims to model and simulate each stage of the shed of the load that is in the electrical system of the city of Kendari using low frequency relays and assess the effectiveness of each stage to return the system frequency and voltage to the value that is still permitted.The results showed that the simulation of each stage of load release with the help of DigSilent Power Factory 10.1.7 software was able to minimize the amount of outages, and was able to restore the System frequency when the frequency was minimal due to the sudden loss of power suppliers(generator). The frequency recovery rate of the study shows the release of loads starting from 2.57 MW - 3.33 MW frequency recovery from 49.4 Hz - 50.00 Hz.Keywords: Frequency and Voltage, Loss generator, Under-Frequency Load Shedding.

Jaringan kolaborasi para penulis

40 penulis · 122 tautan kepenulisan bersama · 6 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Halu Oleo
  • Institut Teknologi dan Bisnis Nobel Indonesia
  • Institut Agama Islam Negeri Kendari
  • State University of Semarang
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mustamin MustaminInstitut Teknologi dan Bisnis Nobel Indonesia4
Waode ZulkaidahUniversitas Halu Oleo3
St Nawal JayaUniversitas Halu Oleo2
Faraditha AmeliaUniversitas Halu Oleo1
Feliks Eldad LarobuUniversitas Halu Oleo1
Agustina LolokUniversitas Halu Oleo1
Abd KadirUniversitas Halu Oleo1
Hanika PasangUniversitas Halu Oleo1
Gamal Abdel NasserUniversitas Halu Oleo1
Agustinus LolokAfiliasi tidak diketahui1
Sahrul HusuAfiliasi tidak diketahui1
Luther PagilingAfiliasi tidak diketahui1
Yuni Aryanu KoedoesAfiliasi tidak diketahui1
Indrayati GaluguAfiliasi tidak diketahui1
Rudi WijayaAfiliasi tidak diketahui1
Jovi Jus DicaprioAfiliasi tidak diketahui1
Rahmad ImranAfiliasi tidak diketahui1
Mustamin MustaminAfiliasi tidak diketahui1
Mansur MansurInstitut Agama Islam Negeri Kendari1
Amirun Bonti SaifuAfiliasi tidak diketahui1
Budi SetiawanAfiliasi tidak diketahui1
Tambi TambiAfiliasi tidak diketahui1
Adurahim AdurahimAfiliasi tidak diketahui1
Achmad Nur AliansyahAfiliasi tidak diketahui1
Nita Zelfia Dinianti Luzi MulyawatiAfiliasi tidak diketahui1
Muh Nadzirin Anshari NurAfiliasi tidak diketahui1
Wa Ode Siti Nur AlamAfiliasi tidak diketahui1
Gamal Abdel Nasser MassikiAfiliasi tidak diketahui1
Sukmawati AbdullahAfiliasi tidak diketahui1
Sarawa MammaUniversitas Halu Oleo1
La Ode Ali ImranAfiliasi tidak diketahui1
Bunyamin BunyaminState University of Semarang1
Abdul DjoharAfiliasi tidak diketahui1
Gamal A NasserAfiliasi tidak diketahui1
Alimin AliminAfiliasi tidak diketahui1
Budiman SudiaUniversitas Halu Oleo1
Tambi TambiAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs.uho.ac.id/index.php/JFE/oai, pertama di-harvest 1 Nov 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">PEMODELAN DAN SIMULASI SKEMA PELEPASAN BEBAN DENGAN RELE FREKUENSI RENDAH SISTEM KELISTRIKAN DI PT. PLN (PERSERO) KOTA KENDARI</dc:title>
	<dc:creator>Sartisya, Risya</dc:creator>
	<dc:creator>Hay, Sahabuddin</dc:creator>
	<dc:creator>Siti Nur Alam, Wa Ode</dc:creator>
	<dc:description xml:lang="en-US">The deviation of the frequency of a power system from its nominal value is a reflection of the mismatch between generation and load. Such deviation are serious and must be monitored and controlled very closely. One major impact of operation outside a narrow range around the nominal frequency is that generators can demaged. To avoid this, manufacturers set time interval limits for under-frequency operation and when such limits are exceeded, the generator trips. Howeever, unless generator tripping is coordinated with some accompanying load shedding, the system inablitiy to supply its load can be exacerbated resulting in an even worse frequency deviation.Under-frequency load shedding (UFLS) is designed to protect the power system from event leading to a sudden drop in system frequency, when the primary frequency regulation built into the generation system is not enough to bring the frequency back to nominal. Under-frequency load shedding disconnect blocks of load when the frequency drop below given threshold. This study aims to model and simulate each stage of the shed of the load that is in the electrical system of the city of Kendari using low frequency relays and assess the effectiveness of each stage to return the system frequency and voltage to the value that is still permitted.The results showed that the simulation of each stage of load release with the help of DigSilent Power Factory 10.1.7 software was able to minimize the amount of outages, and was able to restore the System frequency when the frequency was minimal due to the sudden loss of power suppliers(generator). The frequency recovery rate of the study shows the release of loads starting from 2.57 MW - 3.33 MW frequency recovery from 49.4 Hz - 50.00 Hz.Keywords: Frequency and Voltage, Loss generator, Under-Frequency Load Shedding.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Halu Oleo</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-02-17</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:identifier>https://ojs.uho.ac.id/index.php/JFE/article/view/12334</dc:identifier>
	<dc:identifier>10.33772/jfe.v5i1.12334</dc:identifier>
	<dc:source xml:lang="en-US">Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali); Vol 5, No 1 (2020): Jurnal Elektroda Vol 5 No 1; PDF</dc:source>
	<dc:source>2502-5562</dc:source>
	<dc:source>10.33772/jfe.v5i1</dc:source>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Risya Sartisya, Sahabuddin Hay, Wa Ode Siti Nur Alam</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>