A study about microtremor was developed for Heram District, Jayapura City. This research was purposed to determine predominant frequency, predominant period and amplification of ground motion values based on microtremor recording. Direct measurement in field method was used for this research by using microtremor equipment. Microtremor signal recording was analysed by using HVSR (Horizontal to Vertical Spectral Ratio) method.Microtremor analysis with HVSR method can use to determine ground layer characteristic. The result shows that predominant frequency, predominant period and amplification of ground motion values have variation at every measuring point. The lowest ground predominant period value is 0,0792 s, it means have higher predominant frequency value is 12,6325 Hz at measuring point IX (JPR 50) was located in around of church GPdI Ekklesia Padang Bulan, Hedam Village. The higher ground predominant periode value is 1,5725 s, it means have lowest predominant frequency value about 0,63594 Hz, at measuring point VII (JPR 48) was located in boarder of Yoka Village (Jayapura City) and Puai Village (Jayapura Regency). The higher ground motion amplification factor value is 2,46712 at measuring point VII (JPR 48) was located in boarder of Yoka Village (Jayapura City) and Puai Village (Jayapura Regency). The lowest amplification value is 1,33306 at measuring point IV (JPR 45) was located in around of Beautiful Pemda Housing, Waena Village. Key words: Microtremor, HVSR, frequency, periode, amplification,Hedam District

Collaboration network of the authors

2 authors · 1 co-authorship link

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Endang HaryatiAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://ejournal.uncen.ac.id/index.php/SAINS/oai, first harvested 1 Nov 2026, last seen 1 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">STUDI MIKROTREMOR DENGAN METODE HVSR DI DISTRIK HERAM, KOTA JAYAPURA</dc:title>
	<dc:creator>Mantiri, Steven Y.Y.</dc:creator>
	<dc:description xml:lang="en-US">A study about microtremor was developed for Heram District, Jayapura City. This research was purposed to determine predominant frequency, predominant period and amplification of ground motion values based on microtremor recording. Direct measurement in field method was used for this research by using microtremor equipment. Microtremor signal recording was analysed by using HVSR (Horizontal to Vertical Spectral Ratio) method.Microtremor analysis with HVSR method can use to determine ground layer characteristic. The result shows that predominant frequency, predominant period and amplification of ground motion values have variation at every measuring point. The lowest ground predominant period value is 0,0792 s, it means have higher predominant frequency value is 12,6325 Hz at measuring point IX (JPR 50) was located in around of church GPdI Ekklesia Padang Bulan, Hedam Village. The higher ground predominant periode value is 1,5725 s, it means have lowest predominant frequency value about 0,63594 Hz, at measuring point VII (JPR 48) was located in boarder of Yoka Village (Jayapura City) and Puai Village (Jayapura Regency). The higher ground motion amplification factor value is 2,46712 at measuring point VII (JPR 48) was located in boarder of Yoka Village (Jayapura City) and Puai Village (Jayapura Regency). The lowest amplification value is 1,33306 at measuring point IV (JPR 45) was located in around of Beautiful Pemda Housing, Waena Village. Key words : Microtremor, HVSR, frequency, periode, amplification,Hedam District</dc:description>
	<dc:publisher xml:lang="en-US">Fakultas MIPA - Universitas Cenderwasih</dc:publisher>
	<dc:date>2018-05-29</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ejournal.uncen.ac.id/index.php/SAINS/article/view/271</dc:identifier>
	<dc:identifier>10.31957/sains.v16i2.271</dc:identifier>
	<dc:source xml:lang="en-US">SAINS: Jurnal MIPA dan Pengajarannya; Vol. 16 No. 2 (2016)</dc:source>
	<dc:source xml:lang="id-ID">SAINS: Jurnal MIPA dan Pengajarannya; Vol 16 No 2 (2016)</dc:source>
	<dc:source>1412-1093</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ejournal.uncen.ac.id/index.php/SAINS/article/view/271/242</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 SAINS: Jurnal MIPA dan Pengajarannya</dc:rights>
</oai_dc:dc>