Melola Discovery

← Melola Discovery

Jurnal

Conceptual Design and Fabrication Assessment of a Single Large-Diameter Pile Foundation for Compact Offshore Jacket Structures

Analisis Desain dan Fabrikasi Fondasi Tiang Tunggal pada Struktur Jacket Lepas Pantai

SENSISTEK:Riset Sains dan Teknologi Kelautan · Vol. ume (2026) · pp. 64–76

ISSN
2988-2559, 2623-1506
Published
2026-05-29
Publisher
Departemen Teknik Kelautan Fakultas Teknik Universitas Hasanuddin
Language
en

Abstract

English

A large-diameter single pile is a potentially attractive alternative for simplifying the foundation system of compact offshore jackets; however, concentrating all actions into one load path requires more rigorous geotechnical, structural, fabrication, and installation verification. This paper develops an integrated pre-design framework for assessing the concept. The assessment combines offshore structural design principles, soil–pile load-transfer mechanisms, axial and lateral capacity screening, tubular section stress checks, and fabrication quality planning. An illustrative reference case with a 3.0 m diameter steel pile, 60–80 mm wall thickness, 70 m total length, and 45 m embedment is used to demonstrate the influence of diameter, penetration, soil stiffness, wall thickness, and scour. The screening results indicate that axial resistance increases strongly with diameter and embedment, whereas lateral response is particularly sensitive to soil stiffness, diameter, and scour. For an illustrative combination of 20 MN axial load and 120 MN·m overturning moment, a 60 mm wall gives a combined nominal stress of approximately 337 MPa, leaving limited margin to a 355 MPa yield strength; increasing the wall to 70–80 mm reduces the stress to approximately 291–257 MPa. Fabrication reliability is governed by material traceability, ovality, alignment, welding parameters, non-destructive testing, corrosion protection, and loadout readiness. The concept can be efficient for light-to-medium topsides in relatively uniform ground, but it should not be selected merely because it reduces the number of piles. A final decision requires site-specific ground investigation, nonlinear soil–structure analysis, fatigue verification, drivability assessment, accidental limit-state checks, and installation-spread evaluation.

Bahasa Indonesia

Meningkatnya kebutuhan akan struktur lepas pantai yang efisien secara biaya telah mendorong pengembangan sistem fondasi alternatif, salah satunya adalah fondasi tiang tunggal (single pile foundation). Penelitian ini menyajikan analisis komprehensif terhadap aspek perancangan dan fabrikasi fondasi tiang tunggal yang diterapkan pada struktur offshore jacket. Kajian ini berfokus pada mekanisme transfer beban, interaksi tanah–tiang, integritas struktur, serta tantangan dalam proses fabrikasi. Metode yang digunakan meliputi pendekatan analitis dan studi literatur untuk mengevaluasi kelayakan serta kinerja sistem tersebut. Hasil penelitian menunjukkan bahwa fondasi tiang tunggal dapat menjadi solusi yang efisien dan andal pada kondisi tanah dan pembebanan tertentu, dengan syarat dilakukan analisis geoteknik yang mendalam serta pengendalian mutu fabrikasi yang ketat (1).

Keywords

Collaboration network of the authors

2 authors · 1 co-authorship link

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Habibi PalippuiAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

Metadata source: OAI-PMH (metadata jurnal) https://journal.unhas.ac.id/index.php/SENSISTEK/oai, first harvested 2 Nov 2026, last seen 2 Nov 2026.
Original metadata (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Conceptual Design and Fabrication Assessment of a Single Large-Diameter Pile Foundation for Compact Offshore Jacket Structures</dc:title>
	<dc:title xml:lang="id">Analisis Desain dan Fabrikasi Fondasi Tiang Tunggal pada Struktur Jacket Lepas Pantai</dc:title>
	<dc:creator xml:lang="en">Ramadhan, Sahwan</dc:creator>
	<dc:creator xml:lang="id">Ramadhan, Sahwan</dc:creator>
	<dc:subject xml:lang="id">Fondasi Tiang Tunggal</dc:subject>
	<dc:subject xml:lang="id">Offshore Jacket</dc:subject>
	<dc:subject xml:lang="id">Fabrikasi</dc:subject>
	<dc:subject xml:lang="id">Interaksi Tanah–Struktur</dc:subject>
	<dc:subject xml:lang="id">Teknik Lepas Pantai</dc:subject>
	<dc:subject xml:lang="en">Offshore Engineering</dc:subject>
	<dc:subject xml:lang="en">Single Pile Foundation</dc:subject>
	<dc:subject xml:lang="en">Offshore Jacket</dc:subject>
	<dc:subject xml:lang="en">Fabrication</dc:subject>
	<dc:subject xml:lang="en">Soil–Structure Interaction</dc:subject>
	<dc:description xml:lang="en">A large-diameter single pile is a potentially attractive alternative for simplifying the foundation system of compact offshore jackets; however, concentrating all actions into one load path requires more rigorous geotechnical, structural, fabrication, and installation verification. This paper develops an integrated pre-design framework for assessing the concept. The assessment combines offshore structural design principles, soil–pile load-transfer mechanisms, axial and lateral capacity screening, tubular section stress checks, and fabrication quality planning. An illustrative reference case with a 3.0 m diameter steel pile, 60–80 mm wall thickness, 70 m total length, and 45 m embedment is used to demonstrate the influence of diameter, penetration, soil stiffness, wall thickness, and scour. The screening results indicate that axial resistance increases strongly with diameter and embedment, whereas lateral response is particularly sensitive to soil stiffness, diameter, and scour. For an illustrative combination of 20 MN axial load and 120 MN·m overturning moment, a 60 mm wall gives a combined nominal stress of approximately 337 MPa, leaving limited margin to a 355 MPa yield strength; increasing the wall to 70–80 mm reduces the stress to approximately 291–257 MPa. Fabrication reliability is governed by material traceability, ovality, alignment, welding parameters, non-destructive testing, corrosion protection, and loadout readiness. The concept can be efficient for light-to-medium topsides in relatively uniform ground, but it should not be selected merely because it reduces the number of piles. A final decision requires site-specific ground investigation, nonlinear soil–structure analysis, fatigue verification, drivability assessment, accidental limit-state checks, and installation-spread evaluation.</dc:description>
	<dc:description xml:lang="id">Meningkatnya kebutuhan akan struktur lepas pantai yang efisien secara biaya telah mendorong pengembangan sistem fondasi alternatif, salah satunya adalah fondasi tiang tunggal (single pile foundation). Penelitian ini menyajikan analisis komprehensif terhadap aspek perancangan dan fabrikasi fondasi tiang tunggal yang diterapkan pada struktur offshore jacket. Kajian ini berfokus pada mekanisme transfer beban, interaksi tanah–tiang, integritas struktur, serta tantangan dalam proses fabrikasi. Metode yang digunakan meliputi pendekatan analitis dan studi literatur untuk mengevaluasi kelayakan serta kinerja sistem tersebut. Hasil penelitian menunjukkan bahwa fondasi tiang tunggal dapat menjadi solusi yang efisien dan andal pada kondisi tanah dan pembebanan tertentu, dengan syarat dilakukan analisis geoteknik yang mendalam serta pengendalian mutu fabrikasi yang ketat (1).</dc:description>
	<dc:publisher xml:lang="en">Departemen Teknik Kelautan Fakultas Teknik Universitas Hasanuddin</dc:publisher>
	<dc:date>2026-05-29</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unhas.ac.id/index.php/SENSISTEK/article/view/50816</dc:identifier>
	<dc:source xml:lang="en">SENSISTEK:Riset Sains dan Teknologi Kelautan; Volume 9, Number 1, Tahun 2026; 64-76</dc:source>
	<dc:source xml:lang="id">Riset Sains dan Teknologi Kelautan; Volume 9, Number 1, Tahun 2026; 64-76</dc:source>
	<dc:source>2988-2559</dc:source>
	<dc:source>2623-1506</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unhas.ac.id/index.php/SENSISTEK/article/view/50816/14466</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Riset Sains dan Teknologi Kelautan</dc:rights>
</oai_dc:dc>