Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

PHYSICO-CHEMICAL ANALYSIS OF POWER PLANT EFFLUENT DISCHARGE ON EKEMAZU STREAM IN DELTA STATE, NIGERIA.

International Journal of Applied Biology · Vol. 6 No. 1 (2022) · hlm. 38–52

ISSN
2580-2119, 2580-2410
Terbit
2022-07-07
Penerbit
Hasanuddin University
Bahasa
en

Abstrak

Physicochemical analysis of Ekemazu stream in Delta State, Nigeria was carried out to assess the water quality between September 2014 and June 2015. Physicochemical parameters were analyzed according to standard methods for examination of water and wastewater. The turbidity of all the samples analysed across the seasons showed that the value was highest at the effluent discharge point at the peak of the flood season and least in the upstream at the setting – in of raining season in the following range: upstream; 12 ± 1 NTU to 25 ± 0 NTU, effluent discharge point; 121 ± 0 NTU to 423 ± 39 NTU, domestic activities point; 85 ± 2 NTU to 373 ± 40 NTU and in the downstream; 70 ± 0 NTU to 341 ± 44 NTU. All other parameters analyzed followed similar trend (highest in the effluent discharge point) either during the peak of flood season or peak of raining season and least in the upstream sample at other seasons. The statistical analysis of the difference in the physicochemical parameters of the upstream samples and the values obtained in effluent discharge point, domestic activities point and the downstream were all significant (P<0.05). This research clearly showed that some physicochemical parameters of the stream are higher than the WHO acceptable limit. This is due to the release of heavily polluted effluent into the stream, seasonal variations as well as some human activities in the water body resulting to high pollution of the stream.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Favour PeterAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unhas.ac.id/index.php/ijoab/oai, pertama di-harvest 3 Nov 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">PHYSICO-CHEMICAL ANALYSIS OF POWER PLANT EFFLUENT DISCHARGE ON EKEMAZU STREAM IN DELTA STATE, NIGERIA.</dc:title>
	<dc:creator xml:lang="en">Emmanuel-Akerele, Hilda</dc:creator>
	<dc:subject xml:lang="en">Effluent</dc:subject>
	<dc:subject xml:lang="en">Physicochemical</dc:subject>
	<dc:subject xml:lang="en">Pollution</dc:subject>
	<dc:subject xml:lang="en">Stream</dc:subject>
	<dc:description xml:lang="en">Physicochemical analysis of Ekemazu stream in Delta State, Nigeria was carried out to assess the water quality between September 2014 and June 2015. Physicochemical parameters were analyzed according to standard methods for examination of water and wastewater. The turbidity of all the samples analysed across the seasons showed that the value was highest at the effluent discharge point at the peak of the flood season and least in the upstream at the setting – in of raining season in the following range: upstream; 12 ± 1 NTU to 25 ± 0 NTU, effluent discharge point; 121 ± 0 NTU to 423 ± 39 NTU, domestic activities point; 85 ± 2 NTU to 373 ± 40 NTU and in the downstream; 70 ± 0 NTU to 341 ± 44 NTU. All other parameters analyzed followed similar trend (highest in the effluent discharge point) either during the peak of flood season or peak of raining season and least in the upstream sample at other seasons. The statistical analysis of the difference in the physicochemical parameters of the upstream samples and the values obtained in effluent discharge point, domestic activities point and the downstream were all significant (P&amp;lt;0.05). This research clearly showed that some physicochemical parameters of the stream are higher than the WHO acceptable limit. This is due to the release of heavily polluted effluent into the stream, seasonal variations as well as some human activities in the water body resulting to high pollution of the stream.
&amp;nbsp;</dc:description>
	<dc:publisher xml:lang="en">Hasanuddin University</dc:publisher>
	<dc:date>2022-07-07</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unhas.ac.id/index.php/ijoab/article/view/18996</dc:identifier>
	<dc:source xml:lang="en">International Journal of Applied Biology; Vol. 6 No. 1 (2022): International Journal of Applied Biology; 38-52</dc:source>
	<dc:source>2580-2119</dc:source>
	<dc:source>2580-2410</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unhas.ac.id/index.php/ijoab/article/view/18996/8404</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2022 International Journal of Applied Biology</dc:rights>
</oai_dc:dc>