Jurnal
SINTA 3
PENERAPAN PERSAMAAN GEOTERMOMETER (SiO2)p DI LAPANGAN PANAS BUMI SULI, AMBON
BAREKENG: Jurnal Ilmu Matematika dan Terapan · Vol. 6 No. 2 (2012) · hlm. 33–36
ISSN 2615-3017, 1978-7227
Terbit 2012-12-01
Penerbit PATTIMURA UNIVERSITY
Bahasa eng
Abstrak
Suli hot springs area has a low level of acidity or neutral pH ranges (7,2–7,7). It is also supported by a high chloride concentration value, which ranges (208,87-226,27) ppm. Thisshows that the area on station 1, 2, 3, and 4 are located in areas with water flow into the upper reservoir (upflow) and belongs to hot water domination reservoir tipe (water heatedreservoir). Reservoir temperature is calculated by the formula geotermometer (SiO2)p considered whether applied in the four kinds geotermometer equation because it gives the calculation results are not much different temperature and has a value of rms-error is less than 2%. Reservoir temperature at a hot springs station Suli possible temperature (161 ± 0,9)oC. Reservoir temperature at station 2 hot spring Suli possible hot water temperature (172 ± 1,0)oC. Reservoir temperature at station 3 hot springs Suli possible temperature (171 ±0,9)oC. Reservoir temperature at station 4 hot springs Suli possible temperature (169 ± 1,0)oC.
Jaringan kolaborasi para penulis
Belum ada rekan penulis di Melola.
Sumber metadata: OAI-PMH (metadata jurnal) https://ojs3.unpatti.ac.id/index.php/barekeng/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">PENERAPAN PERSAMAAN GEOTERMOMETER (SiO2)p DI LAPANGAN PANAS BUMI SULI, AMBON</dc:title>
<dc:creator>Handayani, Helda</dc:creator>
<dc:description xml:lang="en-US">Suli hot springs area has a low level of acidity or neutral pH ranges (7,2–7,7). It is also supported by a high chloride concentration value, which ranges (208,87-226,27) ppm. Thisshows that the area on station 1, 2, 3, and 4 are located in areas with water flow into the upper reservoir (upflow) and belongs to hot water domination reservoir tipe (water heatedreservoir). Reservoir temperature is calculated by the formula geotermometer (SiO2)p considered whether applied in the four kinds geotermometer equation because it gives the calculation results are not much different temperature and has a value of rms-error is less than 2%. Reservoir temperature at a hot springs station Suli possible temperature (161 ± 0,9)oC. Reservoir temperature at station 2 hot spring Suli possible hot water temperature (172 ± 1,0)oC. Reservoir temperature at station 3 hot springs Suli possible temperature (171 ±0,9)oC. Reservoir temperature at station 4 hot springs Suli possible temperature (169 ± 1,0)oC.</dc:description>
<dc:publisher xml:lang="en-US">PATTIMURA UNIVERSITY</dc:publisher>
<dc:date>2012-12-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/210</dc:identifier>
<dc:identifier>10.30598/barekengvol6iss2pp33-36</dc:identifier>
<dc:source xml:lang="en-US">BAREKENG: Jurnal Ilmu Matematika dan Terapan; Vol 6 No 2 (2012): BAREKENG : Jurnal Ilmu Matematika dan Terapan; 33-36</dc:source>
<dc:source>2615-3017</dc:source>
<dc:source>1978-7227</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/210/180</dc:relation>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 8 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref, doaj.
Sitasi artikel ini
APA 7
Handayani, H. (2012). PENERAPAN PERSAMAAN GEOTERMOMETER (SiO2)p DI LAPANGAN PANAS BUMI SULI, AMBON. BAREKENG: Jurnal Ilmu Matematika dan Terapan, 6(2), 33–36. https://doi.org/10.30598/barekengvol6iss2pp33-36
Salin
IEEE
H. Handayani, “PENERAPAN PERSAMAAN GEOTERMOMETER (SiO2)p DI LAPANGAN PANAS BUMI SULI, AMBON,” BAREKENG: Jurnal Ilmu Matematika dan Terapan, vol. 6, no. 2, pp. 33–36, 2012, doi: 10.30598/barekengvol6iss2pp33-36.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.