Melola Discovery

← Melola Discovery

Jurnal SINTA 3

OPTIMASI PEMBACAAN SUHU KAMERA TERMAL MENGGUNAKAN REGRESI LINIER

BAREKENG: Jurnal Ilmu Matematika dan Terapan · Vol. 15 No. 1 (2021) · hlm. 127–136

DOI
10.30598/barekengvol15iss1pp127-136
ISSN
2615-3017, 1978-7227
Terbit
2021-03-01
Penerbit
PATTIMURA UNIVERSITY
Bahasa
eng

Abstrak

Fever is one of the symptoms of a person with Covid-19. Body temperature must be checked e before entering crowded areas such as schools, offices, shops, and hospitals. It is a mandatory protocol that must be done. One of the tools that can be used to check body temperature is a thermal camera. Thermal cameras have the disadvantage of a high temperature reading error. This is because the thermal camera used has a low resolution. This study aims to reduce the value of the temperature reading error on the thermal camera using the linear regression method. The linear regression method is able to reduce the error rate of temperature readings by 5.27% at 36 ° C reading. The reduction in reading error also occurred by 5.27% at 37 ° C and 6.44% at 38 ° C. Based on the results obtained, this study shows that linear regression can be applied to thermal cameras and provides a decrease in the error rate of temperature readings on thermal cameras

Jaringan kolaborasi para penulis

16 penulis · 35 tautan kepenulisan bersama · 9 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Telkom Purwokerto
  • Institut Teknologi Telkom Surabaya
  • Politeknik Surabaya
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Anggun Fitrian IsnawatiInstitut Teknologi Telkom Purwokerto2
Helmy WidyantaraInstitut Teknologi Telkom Surabaya2
Chandra AgustinahInstitut Teknologi Telkom Purwokerto2
Risa Farid CrisiantiInstitut Teknologi Telkom Purwokerto2
Prieska MarinaInstitut Teknologi Telkom Purwokerto1
Dimas AdiputraInstitut Teknologi Telkom Surabaya1
Isa HafidzInstitut Teknologi Telkom Surabaya1
Billy MontolaluInstitut Teknologi Telkom Surabaya1
Wahyu Andy PrastyabudiInstitut Teknologi Telkom Surabaya1
Brayan RaynaldiInstitut Teknologi Telkom Purwokerto1
Ristanti AkseptoriPoliteknik Surabaya1
Ubaidilah UmarInstitut Teknologi Telkom Surabaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs3.unpatti.ac.id/index.php/barekeng/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">OPTIMASI PEMBACAAN SUHU KAMERA TERMAL MENGGUNAKAN REGRESI LINIER</dc:title>
	<dc:creator>Purnama, Sevia Indah</dc:creator>
	<dc:creator>Hikmah, Irmayatul</dc:creator>
	<dc:creator>Afandi, Mas Aly</dc:creator>
	<dc:creator>Mulyani, Elsa Sri</dc:creator>
	<dc:description xml:lang="en-US">Fever is one of the symptoms of a person with Covid-19. Body temperature must be checked e before entering crowded areas such as schools, offices, shops, and hospitals. It is a mandatory protocol that must be done. One of the tools that can be used to check body temperature is a thermal camera. Thermal cameras have the disadvantage of a high temperature reading error. This is because the thermal camera used has a low resolution. This study aims to reduce the value of the temperature reading error on the thermal camera using the linear regression method. The linear regression method is able to reduce the error rate of temperature readings by 5.27% at 36 ° C reading. The reduction in reading error also occurred by 5.27% at 37 ° C and 6.44% at 38 ° C. Based on the results obtained, this study shows that linear regression can be applied to thermal cameras and provides a decrease in the error rate of temperature readings on thermal cameras</dc:description>
	<dc:publisher xml:lang="en-US">PATTIMURA UNIVERSITY</dc:publisher>
	<dc:date>2021-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/3029</dc:identifier>
	<dc:identifier>10.30598/barekengvol15iss1pp127-136</dc:identifier>
	<dc:source xml:lang="en-US">BAREKENG: Jurnal Ilmu Matematika dan Terapan; Vol 15 No 1 (2021): BAREKENG: Jurnal Ilmu Matematika dan Terapan; 127-136</dc:source>
	<dc:source>2615-3017</dc:source>
	<dc:source>1978-7227</dc:source>
	<dc:source>10.30598/barekengvol15iss1year2021</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs3.unpatti.ac.id/index.php/barekeng/article/view/3029/2703</dc:relation>
</oai_dc:dc>