Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Voltage Instability of Initiation Fault Duration as Influenced by Nodes Short Circuit Levels NSCL with Different Types of Loads

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 6 No. 3 (2016)

DOI
10.11591/ijece.v6i3.10163
ISSN
2088-8708, 2088-8708
Published
2016-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc-nd/4.0

Abstract

The occurrence of voltage instabilities or voltage collapses depend on the duration of the persistence of the fault and on the type of fault, some faults lead to voltage instabilities, others lead to voltage collapse. Evaluation of fault durations causing occurrence of voltage instabilities is the main goal of this paper. This paper searches for the effect of nodes short circuit levels NSCL and its duration periods initiation of voltage instability, with lagging and leading load power factors at certain loads buses. In this paper, the power system dynamic simulation program is developed for dynamic analysis of voltage stability. This paper is concerned with the fault duration which lead to the occurrence of voltage instability phenomena due to NSCL. The fault which lead to voltage instability is found to be short circuits at certain nodes cleared without any variation in the transmission system elements, i.e. the post-fault conditions will be the same as the pre-fault conditions. Models for loads considered in this study are induction motors with three different shaft mechanical loads, constant impedance CZ loads, constant current CI loads and constant power CP loads are used, as they depict the behavior of most power system loads. The influence of the transmission network impedances, which are nearly the inverse of the NSCL, on the fault duration which lead to the occurrence of voltage instabilities are studied and evaluated using various load representations.

Collaboration network of the authors

6 authors · 9 co-authorship links · 3 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Aswan University
  • King Abdulaziz University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Ahmed ThabetAswan University7
Safaa AbdelhadyAswan University2
Nourhan SalemAswan University1
A. M. El-nobyAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Voltage Instability of Initiation Fault Duration as Influenced by Nodes Short Circuit Levels NSCL with Different Types of Loads</dc:title><dc:creator>Mobarak, Youssef Ahmed</dc:creator><dc:creator>Hussein, Mahmoud M.</dc:creator><dc:description>&lt;jats:p&gt;The occurrence of voltage instabilities or voltage collapses depend on the duration of the persistence of the fault and on the type of fault, some faults lead to voltage instabilities, others lead to voltage collapse. Evaluation of fault durations causing occurrence of voltage instabilities is the main goal of this paper. This paper searches for the effect of nodes short circuit levels NSCL and its duration periods initiation of voltage instability, with lagging and leading load power factors at certain loads buses. In this paper, the power system dynamic simulation program is developed for dynamic analysis of voltage stability. This paper is concerned with the fault duration which lead to the occurrence of voltage instability phenomena due to NSCL. The fault which lead to voltage instability is found to be short circuits at certain nodes cleared without any variation in the transmission system elements, i.e. the post-fault conditions will be the same as the pre-fault conditions. Models for loads considered in this study are induction motors with three different shaft mechanical loads, constant impedance CZ loads, constant current CI loads and constant power CP loads are used, as they depict the behavior of most power system loads. The influence of the transmission network impedances, which are nearly the inverse of the NSCL, on the fault duration which lead to the occurrence of voltage instabilities are studied and evaluated using various load representations.&amp;lt;strong&amp;gt;&amp;lt;em&amp;gt;&amp;lt;/em&amp;gt;&amp;lt;/strong&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2016-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v6i3.10163</dc:identifier><dc:identifier>10.11591/ijece.v6i3.10163</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 6 No 3 (2016); 1305</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://www.iaescore.com/journals/index.php/IJECE/article/viewFile/486/364</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc-nd/4.0</dc:rights></oai_dc:dc>