Melola Discovery

← Melola Discovery

Akses terbuka Jurnal

DOSIMETRIC EVALUATION AND MATHEMATICAL MODELING OF AIR KERMA IN LOWER EXTREMITY RADIOGRAPHY

Jurnal Ilmiah Ilmu Terapan Universitas Jambi · Vol. 10 No. 3 (2026) · hlm. 1557–1569

DOI
10.22437/jiituj.v10i3.56453
ISSN
2580-2259, 2580-2240
Terbit
2026-06-30
Penerbit
LPPM Universitas Jambi
Bahasa
en
Lisensi
creativecommons.org/licenses/by/4.0

Abstrak

Achieving an optimal balance between diagnostic image quality and radiation dosimetry is foundational to effective diagnostic imaging and the ALARA principle. The aim of this study is to analyze Incident Air Kerma (INAK) and Entrance Surface Air Kerma (ESAK) values from general radiograph examination to evaluate diagnostic efficacy and radiation safety. Baseline data were collected from quality control compliance testing of a Radnext32 Hitachi Computed Radiography system. Subsequently, data analysis was conducted on a lower extremity radiographic survey, encompassing over 30 patients per region using a constant focus-to-film distance of 100 cm. By using graph plotting tool in Microsoft excel, it revealed a robust correlation between tube voltage (kV) and INAK (R2>0.99), modeled by the power function trendline y=5.10-6x2,1593. Femur examinations result in the highest ESAK values (0.20–0.60 mGy, outliers to 0.92 mGy), while genu, cruris, and ankle doses clustered tightly between 0.04–0.37 mGy. All values complied with the Indonesia Dose Reference Level (I-DRL) and IAEA guidelines. Radiation dose correlated linearly with body weight, though data dispersion suggests confounding anthropometric variables (sex, age, height) influence optimization. Discussion: This study establishes critical baseline dosimetry for lower extremity radiography. Its novelty lies in establishing a precise mathematical power function to predict INAK and ESAK changes specifically for lower extremities based on real-world clinical data. These findings advance radiation research by highlighting that standard weight-based dosing is insufficient; future optimization protocols must multi-variably integrate diverse patient anthropometrics and mandatory source-to-surface distance measurement to refine clinical standard operating procedures.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 26 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Satya Wacana Christian University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Adi SetiawanSatya Wacana Christian University2
Bambang SusantoSatya Wacana Christian University2
Muhammad HidayatullahAfiliasi tidak diketahui2
Pandu KurniantoSatya Wacana Christian University2
Suryasatriya TrihandaruAfiliasi tidak diketahui1
Galuh Retno UtariAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://online-journal.unja.ac.id/index.php/JIITUJ/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">DOSIMETRIC EVALUATION AND MATHEMATICAL MODELING OF AIR KERMA IN LOWER EXTREMITY RADIOGRAPHY</dc:title>
	<dc:creator xml:lang="en">Maslebu, Giner</dc:creator>
	<dc:creator xml:lang="en">Muninggar, Jodelin</dc:creator>
	<dc:creator xml:lang="en">Tita, Faldy</dc:creator>
	<dc:creator xml:lang="en">Yulandewi, Yemima Sandra</dc:creator>
	<dc:creator xml:lang="en">Prakoso, Harya Abdi</dc:creator>
	<dc:creator xml:lang="en">Koleba, Mauren Abigail</dc:creator>
	<dc:subject xml:lang="en">INAK</dc:subject>
	<dc:subject xml:lang="en">ESAK</dc:subject>
	<dc:subject xml:lang="en">Lower Extremity</dc:subject>
	<dc:subject xml:lang="en">Computed Radiograph</dc:subject>
	<dc:description xml:lang="en">Achieving an optimal balance between diagnostic image quality and radiation dosimetry is foundational to effective diagnostic imaging and the ALARA principle. The aim of this study is to analyze Incident Air Kerma (INAK) and Entrance Surface Air Kerma (ESAK) values from general radiograph examination to evaluate diagnostic efficacy and radiation safety. Baseline data were collected from quality control compliance testing of a Radnext32 Hitachi Computed Radiography system. Subsequently, data analysis was conducted on a lower extremity radiographic survey, encompassing over 30 patients per region using a constant focus-to-film distance of 100 cm.  By using graph plotting tool in Microsoft excel, it revealed a robust correlation between tube voltage (kV) and INAK (R2&amp;gt;0.99), modeled by the power function trendline y=5.10-6x2,1593. Femur examinations result in the highest ESAK values (0.20–0.60 mGy, outliers to 0.92 mGy), while genu, cruris, and ankle doses clustered tightly between 0.04–0.37 mGy. All values complied with the Indonesia Dose Reference Level (I-DRL) and IAEA guidelines. Radiation dose correlated linearly with body weight, though data dispersion suggests confounding anthropometric variables (sex, age, height) influence optimization. Discussion: This study establishes critical baseline dosimetry for lower extremity radiography. Its novelty lies in establishing a precise mathematical power function to predict INAK and ESAK changes specifically for lower extremities based on real-world clinical data. These findings advance radiation research by highlighting that standard weight-based dosing is insufficient; future optimization protocols must multi-variably integrate diverse patient anthropometrics and mandatory source-to-surface distance measurement to refine clinical standard operating procedures.</dc:description>
	<dc:publisher xml:lang="en">LPPM Universitas Jambi</dc:publisher>
	<dc:date>2026-06-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://online-journal.unja.ac.id/JIITUJ/article/view/56453</dc:identifier>
	<dc:identifier>10.22437/jiituj.v10i3.56453</dc:identifier>
	<dc:source xml:lang="en">Jurnal Ilmiah Ilmu Terapan Universitas Jambi; Vol. 10 No. 3 (2026): Volume 10, Nomor 3, June 2026; 1557-1569</dc:source>
	<dc:source>2580-2259</dc:source>
	<dc:source>2580-2240</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://online-journal.unja.ac.id/JIITUJ/article/view/56453/24677</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2026 Giner Maslebu, Jodelin Muninggar, Faldy Tita, Yemima Sandra Yulandewi, Harya Abdi Prakoso, Mauren Abigail Koleba</dc:rights>
	<dc:rights xml:lang="en">https://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>