Akses terbuka
Jurnal
Tanpa peringkat SINTA
Perbandingan Remifentanil Kontinu 0.15 Mcg/Kgbb dengan Fentanyl 3 Mcg/Kgbb pada Intubasi Endotrakeal Diukur Menggunakan Pupillometer (AlgiScan®)
Nusantara Medical Science Journal · Vol. ume No. 2 (2021) · hlm. 71–79
ISSN 2597-7288, 2460-9757
Terbit 2021-04-05
Penerbit Faculty of Medicine, Hasanuddin University.
Bahasa en
Abstrak
Introduction: All opioids have varying levels of sedative effects with increasing dosages, although with different strengths. Therefore, the opioid component as a sedative regiment is usually maintained at minimum dose for adequate analgesic with regard to patient comfort. Along with the progress of knowledge, parameters have been found to measure the level of analgesic and sedative. Methods: The principle of measurement is done by using the diameter of pupil and then analyzed through AlgiScan and compared to certain standards. The using of pupilometers AlgiScan in assessing the level of sedative analgesic will reduce the level of subjectivity and errors in measurement. Results: The use of Remifentanil has a faster effect of sedative as proven by lower “AlgiScan” score in the pre-intubation phase. In addition, the use of Remifentanil also provides a hemodynamic view of lower arterial pressure, both pre and post intubation condition. Conclussion: Both Remifentanil and fentanyl are able to provide analgesic with sedative and stable hemodynamics. Remifentanil is proven to be superior with better and faster effect and also faster substance elimination with lower doses.
Jaringan kolaborasi para penulis
6 penulis ·
9 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unhas.ac.id/index.php/jmednus/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Perbandingan Remifentanil Kontinu 0.15 Mcg/Kgbb dengan Fentanyl 3 Mcg/Kgbb pada Intubasi Endotrakeal Diukur Menggunakan Pupillometer (AlgiScan®)</dc:title>
<dc:creator xml:lang="en">Bachtiar Amin, Fauzan</dc:creator>
<dc:creator xml:lang="en"> A.A Husain, Alamsyah</dc:creator>
<dc:creator xml:lang="en">Musba, Andi Muhammad Takdir </dc:creator>
<dc:creator xml:lang="en">Ahmad, Muh Ramli </dc:creator>
<dc:subject xml:lang="en">Fentanyl</dc:subject>
<dc:subject xml:lang="en">Remifentanyl</dc:subject>
<dc:subject xml:lang="en">Intubation</dc:subject>
<dc:subject xml:lang="en">Algiscan</dc:subject>
<dc:description xml:lang="en">Introduction: All opioids have varying levels of sedative effects with increasing dosages, although with different strengths. Therefore, the opioid component as a sedative regiment is usually maintained at minimum dose for adequate analgesic with regard to patient comfort. Along with the progress of knowledge, parameters have been found to measure the level of analgesic and sedative. Methods: The principle of measurement is done by using the diameter of pupil and then analyzed through AlgiScan and compared to certain standards. The using of pupilometers AlgiScan in assessing the level of sedative analgesic will reduce the level of subjectivity and errors in measurement. Results: The use of Remifentanil has a faster effect of sedative as proven by lower “AlgiScan” score in the pre-intubation phase. In addition, the use of Remifentanil also provides a hemodynamic view of lower arterial pressure, both pre and post intubation condition. Conclussion: Both Remifentanil and fentanyl are able to provide analgesic with sedative and stable hemodynamics. Remifentanil is proven to be superior with better and faster effect and also faster substance elimination with lower doses.</dc:description>
<dc:publisher xml:lang="en">Faculty of Medicine, Hasanuddin University.</dc:publisher>
<dc:date>2021-04-05</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.unhas.ac.id/index.php/jmednus/article/view/9912</dc:identifier>
<dc:identifier>10.20956/nmsj.v5i2.9912</dc:identifier>
<dc:source xml:lang="en">Nusantara Medical Science Journal; Volume 5 No. 2 Juli - Desember 2020; 71-79</dc:source>
<dc:source>2597-7288</dc:source>
<dc:source>2460-9757</dc:source>
<dc:source>10.20956/nmsj.v5i2</dc:source>
<dc:language>en</dc:language>
<dc:relation>https://journal.unhas.ac.id/index.php/jmednus/article/view/9912/6696</dc:relation>
<dc:rights xml:lang="en">Copyright (c) 2021 Nusantara Medical Science Journal</dc:rights>
<dc:rights xml:lang="en">https://creativecommons.org/licenses/by/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 8 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Bachtiar Amin, F., A.A Husain, A., Musba, A. M. T., & Ahmad, M. R. (2021). Perbandingan Remifentanil Kontinu 0.15 Mcg/Kgbb dengan Fentanyl 3 Mcg/Kgbb pada Intubasi Endotrakeal Diukur Menggunakan Pupillometer (AlgiScan®). Nusantara Medical Science Journal, ume(2), 71–79. https://doi.org/10.20956/nmsj.v5i2.9912
Salin
IEEE
F. Bachtiar Amin, A. A.A Husain, A. M. T. Musba, and M. R. Ahmad, “Perbandingan Remifentanil Kontinu 0.15 Mcg/Kgbb dengan Fentanyl 3 Mcg/Kgbb pada Intubasi Endotrakeal Diukur Menggunakan Pupillometer (AlgiScan®),” Nusantara Medical Science Journal, vol. ume, no. 2, pp. 71–79, 2021, doi: 10.20956/nmsj.v5i2.9912.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.