The study aimed to investigate and obtain model values of system unavailability and cost of energy not supplied in existing Nigerian township electricity distributions using a robust representative system. Outage data was obtained from system records for analysis using frequency distribution statistics to identify the causes of outages, and the contribution of each cause of outage to the overall system outage. The cost of energy not supplied (CENS) due to faults, was evaluated at a rate of NGN6 per kWHr. An analysis of the results shows that in a distribution feeder (and system) unavailability is mainly due to load shedding arising and faults; feeder unavailability involving load shedding is 0.25, and 0.1 without load shedding. Compared with standard UA value for well managed systems of less than or 0.01, the obtained unavailability values for a feeder show that downtime management was poor, and the corresponding cost – prohibitive. In view of the regular load shedding on the feeders and poor downtime management, this study recommends a need to obtain model loadflow perspective of township electricity distribution to ascertain load carrying capacity, and the application of distribution automation system or other effective strategies to mitigate downtime.

Collaboration network of the authors

3 authors · 2 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Federal University of Technology
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Sola Richard FamakinFederal University of Technology1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 1 Nov 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A Model Unavailability Perspective of Existing Nigerian Township Electricity Distribution</dc:title><dc:creator>Oladipo, Melodi Adegoke</dc:creator><dc:creator>Olusesan, Temikotan Kehinde</dc:creator><dc:description>&lt;jats:p&gt;The study aimed to investigate and obtain model values of system unavailability and cost of energy not supplied in existing Nigerian township electricity distributions using a robust representative system. Outage data was obtained from system records for analysis using frequency distribution statistics to identify the causes of outages, and the contribution of each cause of outage to the overall system outage. The cost of energy not supplied (CENS) due to faults, was evaluated at a rate of NGN6 per kWHr. An analysis of the results shows that in a distribution feeder (and system) unavailability is mainly due to load shedding arising and faults; feeder unavailability involving load shedding is 0.25, and 0.1 without load shedding. Compared with standard UA value for well managed systems of less than or 0.01, the obtained unavailability values for a feeder show that downtime management was poor, and the corresponding cost – prohibitive. In view of the regular load shedding on the feeders and poor downtime management, this study recommends a need to obtain model loadflow perspective of township electricity distribution to ascertain load carrying capacity, and the application of distribution automation system or other effective strategies to mitigate downtime.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i1.pp77-85</dc:identifier><dc:identifier>10.11591/ijece.v7i1.pp77-85</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 1 (2017); 77</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/6255/7931</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>