Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Elbow Flexion and Extension Rehabilitation Exercise System Using Marker-less Kinect-based Method

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 3 (2017)

DOI
10.11591/ijece.v7i3.pp1602-1610
ISSN
2088-8708, 2088-8708
Published
2017-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This paper presents the elbow flexion and extension rehabilitation exercise system using marker-less Kinect-based method. The proposed exercise system is developed for the upper limb rehabilitation application that utilizes a low cost depth sensor. In this study, the Kinect skeleton tracking method is used to detect and track the joints of upper limb and then measure the angle of the elbow joint. The users perform the exercise in front of the Kinect sensor and the computer monitor. At the same time, they can see the results that displayed on the screen in real-time. The measurement of elbow joint angles are recorded automatically and has been compared to the reference values for the analysis and validation. These reference values are obtained from the normal range of motion (ROM) of the elbow. The results show the average flexion angle of the elbow joint that achieved by the normal user is 139.1° for the right hand and 139.2° for the left hand. Meanwhile, the average extension angle is 1.72° for the right hand and 2.0° for the left. These measurements are almost similar to the standard range of motion (ROM) reference values. The skeleton tracking works well and able to follow the movement of the upper arm and forearm in real-time.

Collaboration network of the authors

9 authors · 20 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Khairul Amrizal Abu NawasUniversiti Malaysia Pahang Al-Sultan Abdullah4
Nurnajmin Qasrina AnnUniversiti Malaysia Pahang Al-Sultan Abdullah1
Mohd Fadhil AbasAffiliation unknown1
Luhur BayuajiUniversiti Malaysia Pahang Al-Sultan Abdullah1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Elbow Flexion and Extension Rehabilitation Exercise System Using Marker-less Kinect-based Method</dc:title><dc:creator>Samad, Rosdiyana</dc:creator><dc:creator>Abu Bakar, Muhammad Zabri</dc:creator><dc:creator>Pebrianti, Dwi</dc:creator><dc:creator>Mustafa, Mahfuzah</dc:creator><dc:creator>Abdullah, Nor Rul Hasma</dc:creator><dc:description>&lt;jats:p&gt;This paper presents the elbow flexion and extension rehabilitation exercise system using marker-less Kinect-based method. The proposed exercise system is developed for the upper limb rehabilitation application that utilizes a low cost depth sensor. In this study, the Kinect skeleton tracking method is used to detect and track the joints of upper limb and then measure the angle of the elbow joint. The users perform the exercise in front of the Kinect sensor and the computer monitor. At the same time, they can see the results that displayed on the screen in real-time. The measurement of elbow joint angles are recorded automatically and has been compared to the reference values for the analysis and validation. These reference values are obtained from the normal range of motion (ROM) of the elbow. The results show the average flexion angle of the elbow joint that achieved by the normal user is 139.1° for the right hand and 139.2° for the left hand. Meanwhile, the average extension angle is 1.72° for the right hand and 2.0° for the left. These measurements are almost similar to the standard range of motion (ROM) reference values. The skeleton tracking works well and able to follow the movement of the upper arm and forearm in real-time.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i3.pp1602-1610</dc:identifier><dc:identifier>10.11591/ijece.v7i3.pp1602-1610</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 3 (2017); 1602</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/7529/6580</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>