Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Non-contact Heart Rate Monitoring Analysis from Various Distances with different Face Regions

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 6 (2017)

DOI
10.11591/ijece.v7i6.pp3030-3036
ISSN
2088-8708, 2088-8708
Terbit
2017-12-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

Heart rate (HR) is one of vital biomedical signals for medical diagnosis. Previously, conventional camera is proven to be able to detect small changes in the skin due to the cardiac activity and can be used to measure the HR. However, most of the previous systems operate on near distance mode with a single face patch, thus the feasibility of the remote heart rate for various distances remains vague. This paper tackles this issue by analyzing an optimal framework that capable to works under the mentioned issues. Initially, plausible face landmarks are estimated by employing cascaded of regression mechanism. Next, the region of interest (ROI) was constructed from the landmarks in a face location where non rigid motion is minimal. From the ROI, temporal photoplethysmograph (PPG) signal is calculated based on the average green pixels intensity and environmental illumination is separated using Independent Component Analysis (ICA) filter. Eventually, the PPG signal is further processed using series of temporal filter to exclude frequencies outside the range of interest prior to estimate the HR. As a conclusion, the HR can be detected up to 5 meters range with 94% accuracy using lower part of face region.

Jaringan kolaborasi para penulis

15 penulis · 52 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Syadia Nabilah Mohd SafuanTun Hussein Onn University of Malaysia5
Mohd Norzali Haji MohdTun Hussein Onn University of Malaysia4
Nor Surayahani SurianiTun Hussein Onn University of Malaysia4
Cham Ying KitTun Hussein Onn University of Malaysia3
Jacqueline Ang Jie YiTun Hussein Onn University of Malaysia3
Nicholas Tan Chun ShengTun Hussein Onn University of Malaysia3
Md Nor Ramdon BaharomTun Hussein Onn University of Malaysia3
Muhamad Fikri Shahkhirin BirahimTun Hussein Onn University of Malaysia3
Luqman Nol HakimTun Hussein Onn University of Malaysia3
Muhammad Fuad bin KassimTun Hussein Onn University of Malaysia2
Suhaila SariTun Hussein Onn University of Malaysia2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Non-contact Heart Rate Monitoring Analysis from Various Distances with different Face Regions</dc:title><dc:creator>Ibrahim, Norwahidah</dc:creator><dc:creator>Tomari, Razali</dc:creator><dc:creator>Wan Zakaria, Wan Nurshazwani</dc:creator><dc:creator>Othman, Nurmiza</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span&amp;gt;Heart rate (HR) is one of vital biomedical signals for medical diagnosis. Previously, conventional camera is proven to be able to detect small changes in the skin due to the cardiac activity and can be used to measure the HR. However, most of the previous systems operate on near distance mode with a single face patch, thus the feasibility of the remote heart rate for various distances remains vague. This paper tackles this issue by analyzing an optimal framework that capable to works under the mentioned issues. Initially, plausible face landmarks are estimated by employing cascaded of regression mechanism. Next, the region of interest (ROI) was constructed from the landmarks in a face location where non rigid motion is minimal. From the ROI, temporal photoplethysmograph (PPG) signal is calculated based on the average green pixels intensity and environmental illumination is separated using Independent Component Analysis (ICA) filter. Eventually, the PPG signal is further processed using series of temporal filter to exclude frequencies outside the range of interest prior to estimate the HR. As a conclusion, the HR can be detected up to 5 meters range with 94% accuracy using lower part of face region.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i6.pp3030-3036</dc:identifier><dc:identifier>10.11591/ijece.v7i6.pp3030-3036</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 6 (2017); 3030</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8671/7267</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>