Melola Discovery

← Melola Discovery

Jurnal Tanpa peringkat SINTA

Tofu Wastewater Treatment Planning with Anaerobic Baffled Reactor (ABR) and Activated Sludge Application

Jurnal Ilmu Alam dan Lingkungan · Vol. 12 No. 1 (2021)

DOI
10.70561/jal.v12i1.13092
ISSN
2549-8819, 2086-4604
Terbit
2021-03-01
Penerbit
Universitas Hasanuddin
Bahasa
en

Abstrak

Wastewater from tofu industry produces water with high organic content. Organic pollutant pollution from tofu industry has an impact potential on receiving water bodies. The purpose of the study is to understand the characteristics of the wastewater and conducting the study design of the wastewater treatment plant (WWTP) in the tofu industry. Characterization of tofu industrial wastewater was carried out based on BOD5, COD, TSS, and pH parameters. Sampling was carried out in the tofu-making industrial area of South Sukabumi Village. The organic content in the form of BOD5 and COD respectively is 2843.5 m/L and 7743.5 mg/L. Thus, the aerobic process could not be applied directly as requiring very high oxygen supply. BOD5, COD, TSS, and pH parameters in the industry do not meet Minister of Environment Regulation Number 05 Year 2014 Concerning Wastewater Materials Quality. The units needed in the planning are a collection well, neutralization tank, abr, activated sludge, and final settling tank. Land area needed in the planning of the units is 8.89 m2. The effluent of wastewater which expected to have a neutral pH and the concentration for each BOD5, COD, TSS parameter reaches 24.69 mg/L; 63.32 mg/L; 26.7 mg/L. The total cost of the required WWTP design is Rp 187,977,000.00.

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unhas.ac.id/index.php/jai2/oai, pertama di-harvest 5 Nov 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Tofu Wastewater Treatment Planning with Anaerobic  Baffled Reactor (ABR) and Activated Sludge Application</dc:title>
	<dc:creator xml:lang="en">Naomi Aurora Margareth Br. Simanjuntak</dc:creator>
	<dc:creator xml:lang="en">Nurulbaiti Listyendah Zahra</dc:creator>
	<dc:creator xml:lang="en">I Wayan Koko Suryawan</dc:creator>
	<dc:description xml:lang="en">Wastewater from tofu industry produces water with high organic content. Organic pollutant pollution from tofu industry has an impact potential on receiving water bodies. The purpose of the study is to understand the characteristics of the wastewater and conducting the study design of the wastewater treatment plant (WWTP) in the tofu industry. Characterization of tofu industrial wastewater was carried out based on BOD5, COD, TSS, and pH parameters. Sampling was carried out in the tofu-making industrial area of South Sukabumi Village. The organic content in the form of BOD5 and COD respectively is 2843.5 m/L and 7743.5 mg/L. Thus, the aerobic process could not be applied directly as requiring very high oxygen supply. BOD5, COD, TSS, and pH parameters in the industry do not meet Minister of Environment Regulation Number 05 Year 2014 Concerning Wastewater Materials Quality. The units needed in the planning are a collection well, neutralization tank, abr, activated sludge, and final settling tank. Land area needed in the planning of the units is 8.89 m2. The effluent of wastewater which expected to have a neutral pH and the concentration for each BOD5, COD, TSS parameter reaches 24.69 mg/L; 63.32 mg/L; 26.7 mg/L. The total cost of the required WWTP design is Rp 187,977,000.00.</dc:description>
	<dc:publisher xml:lang="en">Universitas Hasanuddin</dc:publisher>
	<dc:date>2021-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unhas.ac.id/index.php/jai2/article/view/13092</dc:identifier>
	<dc:identifier>10.70561/jal.v12i1.13092</dc:identifier>
	<dc:source xml:lang="en">Jurnal Ilmu Alam dan Lingkungan; Vol. 12 No. 1 (2021): Jurnal Ilmu Alam dan Lingkungan</dc:source>
	<dc:source>2549-8819</dc:source>
	<dc:source>2086-4604</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unhas.ac.id/index.php/jai2/article/view/13092/6549</dc:relation>
</oai_dc:dc>