Abstract

Reliability analysis of substations and generator assessment of power plant stations are very important elements in a design and maintenance process. This paper presents a generator adequacy assessment of a classical “H” scheme for an open conventional substation, which is often used, and a new HIS - High Integrated Switchgear with SF6 gas isolation. Generator adequacy indices of both types of classical and HIS switchgear were compared and the results showed a high level of reliability and availability of the HIS presented substation. The input data were the annual reports of Croatian TSO-Transmission System Operator (HOPS) and statistics of operation events of Croatian National Electricity (HEP Inc.). For the HIS substation, the input reliability data were used from relevant international literature since only few of HIS substations are installed in Croatia. The generator is modelled with a three-state Markov state space model and Monte Carlo simulations were used for the generator assessment analysis. Adequacy indices LOLP and EDNS were obtained using DIgSILENT software.

Collaboration network of the authors

14 authors · 28 co-authorship links · 12 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Osijek
  • Universiti Teknikal Malaysia Melaka
  • Fond za zaštitu okoliša i energetsku učinkovitost
  • Regional Energy Agency
  • Universitas Ahmad Dahlan
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Goran KneževićUniversity of Osijek6
Ljubomir MajdandžićFond za zaštitu okoliša i energetsku učinkovitost5
Dragan MlakićAffiliation unknown5
Predrag MarićUniversity of Osijek5
Zoran BausUniversity of Osijek4
Marko VukobratovićUniversity of Osijek2
Jurica PerkoRegional Energy Agency1
Tole SutiknoUniversitas Ahmad Dahlan1
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka1
Abdul Rahim AbdullahUniversiti Teknikal Malaysia Melaka1
Mustafa ManapUniversiti Teknikal Malaysia Melaka1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Generator Assessment of Hydro Power Station Adequacy after Reconstruction from Classical to HIS SF6 Substation</dc:title><dc:creator>Nikolovski, Srete</dc:creator><dc:creator>Slipac, Goran</dc:creator><dc:creator>Alibašić, Emir</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p&amp;gt;Reliability analysis of substations and generator assessment of power plant stations are very important elements in a design and maintenance process. This paper presents a generator adequacy assessment of a classical “H” scheme for an open conventional substation, which is often used, and a new HIS - High Integrated Switchgear with SF6 gas isolation. Generator adequacy indices of both types of classical and HIS switchgear were compared and the results showed a high level of reliability and availability of the HIS presented substation. The input data were the annual reports of Croatian TSO-Transmission System Operator (HOPS) and statistics of operation events of Croatian National Electricity (HEP Inc.). For the HIS substation, the input reliability data were used from relevant international literature since only few of HIS substations are installed in Croatia. The generator is modelled with a three-state Markov state space model and Monte Carlo simulations were used for the generator assessment analysis. Adequacy indices LOLP and EDNS were obtained using DIgSILENT software.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i2.pp729-740</dc:identifier><dc:identifier>10.11591/ijece.v7i2.pp729-740</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 2 (2017); 729</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/6418/6289</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>