Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Frequency Dependence of Electroluminescence Measurement in LDPE

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 3 (2017)

DOI
10.11591/ijece.v7i3.pp1406-1413
ISSN
2088-8708, 2088-8708
Published
2017-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

A good insulator for high voltage cable has low dielectric loss, reasonable flexibility and thermo-mechanically stable. However, prolonged application of electrical stresses on the cable will degraded the cable; physically and morphologically. Electrical degradation in high voltage cable can be detected using electroluminescence (EL) method. Electroluminescence is a phenomenon that occurs when the atoms of a material are being excited due to the application of and external high electrical stresses. There are several external factors that affect the behaviour of electroluminescence emission such as, applied voltage, applied frequency, ageing of material and types of materials.. In this paper, the EL measurement is employed to determine the effect of applied frequency on virgin LDPE at fixed and varying applied voltage. It can be observed that EL emission increases as applied frequency increases with increasing voltage applied. However, interesting EL behaviour is observed when varying frequency is applied from 10 Hz to 100 Hz.

Collaboration network of the authors

30 authors · 140 co-authorship links · 94 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Technology Malaysia
  • Jubail Industrial College
  • Glasgow Caledonian University
  • Robert Gordon University
  • University of Kuala Lumpur
  • Universidad Técnica Federico Santa María
  • Tun Hussein Onn University of Malaysia
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Jasrul Jamani JamianUniversity of Technology Malaysia8
Z Abdul-MalekUniversity of Technology Malaysia8
Kamilia KamardinUniversity of Technology Malaysia8
Hamza AhmadTun Hussein Onn University of Malaysia8
Daria FreierGlasgow Caledonian University5
Roberto Ramírez-ÍñiguezGlasgow Caledonian University5
Tapas Kumar MallickUniversity of Exeter5
Abu Bakar MunirUniversity of Malaya5
Siti Hajar Mohd YasinUniversiti Teknologi MARA5
Siti Sarah Abu-BakarKing's College London5
Mehrdad MokhtariUniversity of Technology Malaysia4
Chin‐Leong WooiUniversity of Technology Malaysia4
Ali I ElgayarUniversity of Technology Malaysia2
Noor Azlinda AhmadUniversity of Technology Malaysia2
Behnam SalimiUniversity of Technology Malaysia2
Ali I. El GayarAffiliation unknown2
Arunachalam SundaramJubail Industrial College1
Hassan Zuhair Al GarniJubail Industrial College1
Surajudeen AdewusiJubail University College1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Frequency Dependence of Electroluminescence Measurement in LDPE</dc:title><dc:creator>Bani, Nurul Aini</dc:creator><dc:creator>Abdul-Malek, Zulkurnain</dc:creator><dc:creator>Aris, Siti Armiza Mohd</dc:creator><dc:creator>Jalil, Siti Zura A.</dc:creator><dc:creator>Muhtazaruddin, Mohd Nabil</dc:creator><dc:creator>Kaidi, Hazilah Mad</dc:creator><dc:creator>Rahman, Sharipah Alwiah Syed Abd</dc:creator><dc:creator>Muhammad-Sukki, Firdaus</dc:creator><dc:creator>Mas’ud, Abdullahi Abubakar</dc:creator><dc:creator>Abu-Bakar, Siti Hawa</dc:creator><dc:creator>Rey, Jorge Alfredo Ardilla</dc:creator><dc:description>&lt;jats:p&gt;A good insulator for high voltage cable has low dielectric loss, reasonable flexibility and thermo-mechanically stable. However, prolonged application of electrical stresses on the cable will degraded the cable; physically and morphologically. Electrical degradation in high voltage cable can be detected using electroluminescence (EL) method. Electroluminescence is a phenomenon that occurs when the atoms of a material are being excited due to the application of and external high electrical stresses. There are several external factors that affect the behaviour of electroluminescence emission such as, applied voltage, applied frequency, ageing of material and types of materials. . In this paper, the EL measurement is employed to determine the effect of applied frequency on virgin LDPE at fixed and varying applied voltage. It can be observed that EL emission increases as applied frequency increases with increasing voltage applied. However, interesting EL behaviour is observed when varying frequency is applied from 10 Hz to 100 Hz.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i3.pp1406-1413</dc:identifier><dc:identifier>10.11591/ijece.v7i3.pp1406-1413</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 3 (2017); 1406</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/7503/6555</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>