Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A novel integrated dual microneedle-microfluidic impedance flow cytometry for cells detection in suspensions

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 3 (2017)

DOI
10.11591/ijece.v7i3.pp1513-1521
ISSN
2088-8708, 2088-8708
Terbit
2017-06-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

In this study, a new, simple and cost-effective impedance detection of yeast cell concentration by using a novel integrated dual microneedle-microfluidic impedance flow cytometry was introduced. The reported method for impedance flow cytometry detection utilizes embedded electrode and probe in the microfluidic device to perform measurement of electrical impedance when a presence of cells at sensing area. Nonetheless, this method requires costly and complicatedly fabrication process of electrode. Furthermore, to reuse the fabricated electrode, it also requires intensive and tedious cleaning process. Due to that, a dual microneedle integrated at the half height of the microchannel for cell detection as well as for electrical measurement was demonstrated. A commercial available Tungsten needle was utilized as a dual microneedle. The microneedle was easy to be removed from the disposable PDMS microchannel and can be reused with the simple cleaning process, such as washed by using ultrasonic cleaning. Although this device was low cost, it preserves the core functionality of the sensor, which is capable of detecting the passing cells at sensing area. Therefore, this device is suitable for low cost medical and food safety screening and testing process in developing countries.

Jaringan kolaborasi para penulis

7 penulis · 12 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Nagoya University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nurul Bahiah Mohd NoorUniversity of Technology Malaysia1
Nur Fatien Najwa Mohamad NarjiUniversity of Technology Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>A novel integrated dual microneedle-microfluidic impedance flow cytometry for cells detection in suspensions</dc:title><dc:creator>Mansor, Muhammad Asraf</dc:creator><dc:creator>Takeuchi, Masaru</dc:creator><dc:creator>Nakajima, Masahiro</dc:creator><dc:creator>Hasegawa, Yasuhisa</dc:creator><dc:creator>Ahmad, Mohd Ridzuan</dc:creator><dc:description>&lt;jats:p&gt;In this study, a new, simple and cost-effective impedance detection of yeast cell concentration by using a novel integrated dual microneedle-microfluidic impedance flow cytometry was introduced. The reported method for impedance flow cytometry detection utilizes embedded electrode and probe in the microfluidic device to perform measurement of electrical impedance when a presence of cells at sensing area. Nonetheless, this method requires costly and complicatedly fabrication process of electrode. Furthermore, to reuse the fabricated electrode, it also requires intensive and tedious cleaning process. Due to that, a dual microneedle integrated at the half height of the microchannel for cell detection as well as for electrical measurement was demonstrated. A commercial available Tungsten needle was utilized as a dual microneedle. The microneedle was easy to be removed from the disposable PDMS microchannel and can be reused with the simple cleaning process, such as washed by using ultrasonic cleaning. Although this device was low cost, it preserves the core functionality of the sensor, which is capable of detecting the passing cells at sensing area. Therefore, this device is suitable for low cost medical and food safety screening and testing process in developing countries.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i3.pp1513-1521</dc:identifier><dc:identifier>10.11591/ijece.v7i3.pp1513-1521</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 3 (2017); 1513</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/7517/6568</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>