Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Experimental Investigation on Vegetative Oils under Accelerated Thermal Ageing against Their Dielectric Strength

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 3 (2017)

DOI
10.11591/ijece.v7i3.pp1588-1593
ISSN
2088-8708, 2088-8708
Published
2017-06-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Insulation is one of the most important parts in high voltage apparatus such as power transformer. Most power transformer use liquid insulation material, known as power transformer oil. Petroleum-based oil so called mineral oil has been used for many years as power transformer oil. This is due to its high dielectric field strength, low dielectric loses and good long-term performance. This research work has been carried out to investigate the effect of thermal accelerated ageing on electrical properties for several vegetative-based oils. The oil samples that have been used in this research work are soy bean-based oil (FR3) and commercial palm-based oil (PFAE). As comparison, Hyrax mineral oil has also been investigated. The results revealed that vegetative-based oils have as well as dielectric strength compared with mineral oil. It was found that the dielectric strength for all oil samples decreased when undergo the thermal accelerated ageing process.

Collaboration network of the authors

40 authors · 131 co-authorship links · 67 across different organisations · showing the 40 most connected

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Technology Malaysia
  • Universiti Teknikal Malaysia Melaka
  • Jakarta Global University
  • Jenderal Soedirman University
  • Bandung Institute of Technology
  • Universiti Teknologi MARA
  • Universiti Sains Malaysia
  • Other organisations
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Nehaluddin AhmadUniversity of Technology Malaysia5
Noor ‘Aliaa AwangAffiliation unknown5
Faris Akmal SuhainiUniversity of Technology Malaysia5
Izzah Hazirah ZakariaUniversity of Technology Malaysia3
N. A. AwangUniversity of Technology Malaysia3
Mehrdad MokhtariUniversity of Technology Malaysia2
Zulkurnain Abdul‐MalekUniversity of Technology Malaysia2
Chin‐Leong WooiUniversity of Technology Malaysia2
Behnam SalimiUniversity of Technology Malaysia2
M. A. M. PiahUniversity of Technology Malaysia2
N. A. OthmanUniversity of Technology Malaysia2
Nasir A. Al-geelaniAffiliation unknown2
M. S. Mohd Fua’adUniversity of Technology Malaysia2
Rosyid Ridlo Al-HakimIPB University1
Muhammad Haikal SatriaUniversity of Technology Malaysia1
Agung PangestuJakarta Global University1
Hexa Apriliana HidayahJenderal Soedirman University1
Glagah E. SetyowisnuBandung Institute of Technology1
Prihantini PrihantiniBandung Institute of Technology1
Antonius Darma SetiawanJakarta Global University1
Esa Rinjani Cantika PutriJenderal Soedirman University1
Mohd Aizam TalibUniversity of Technology Malaysia1
Z.A. MalekUniversity of Technology Malaysia1
B.T. PhungUNSW Sydney1
M. Hilman AhmadUniversity of Technology Malaysia1
Hidayat ZainuddinUniversiti Teknikal Malaysia Melaka1
Sharin Ab GhaniUniversiti Teknikal Malaysia Melaka1
Imran Sutan ChairulUniversiti Teknikal Malaysia Melaka1
Zulkarnain Ahmad NoordenUniversity of Technology Malaysia1
Muhammad Ilman Hakimi Chua AbdullahUniversiti Teknikal Malaysia Melaka1
A. H. M. NasibUniversity of Technology Malaysia1
Zainuddin NawawiSriwijaya University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Experimental Investigation on Vegetative Oils under Accelerated Thermal Ageing against Their Dielectric Strength</dc:title><dc:creator>Wahid, Siti Sufiah Abd</dc:creator><dc:creator>Taib, Mohd Fikri Hilmi Mohd</dc:creator><dc:creator>Arief, Yanuar Z.</dc:creator><dc:creator>Ahmad, Mohd Hafizi</dc:creator><dc:creator>Ahmad, Noor Azlinda</dc:creator><dc:creator>Muhamad, Nor Asiah</dc:creator><dc:creator>Adzis, Zuraimy</dc:creator><dc:creator>Saad, Mohd Hafiez Izzwan</dc:creator><dc:description>&lt;jats:p&gt;Insulation is one of the most important parts in high voltage apparatus such as power transformer. Most power transformer use liquid insulation material, known as power transformer oil. Petroleum-based oil so called mineral oil has been used for many years as power transformer oil. This is due to its high dielectric field strength, low dielectric loses and good long-term performance. This research work has been carried out to investigate the effect of thermal accelerated ageing on electrical properties for several vegetative-based oils. The oil samples that have been used in this research work are soy bean-based oil (FR3) and commercial palm-based oil (PFAE). As comparison, Hyrax mineral oil has also been investigated. The results revealed that vegetative-based oils have as well as dielectric strength compared with mineral oil.  It was found that the dielectric strength for all oil samples decreased when undergo the thermal accelerated ageing process.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i3.pp1588-1593</dc:identifier><dc:identifier>10.11591/ijece.v7i3.pp1588-1593</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 3 (2017); 1588</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/7527/6578</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>