Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Smart Local Backup Protection for Smart Substation

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 5 (2017)

DOI
10.11591/ijece.v7i5.pp2321-2328
ISSN
2088-8708, 2088-8708
Published
2017-10-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

This paper presents a novel smart local backup protection SLBP used for the support and backup of the protective relays in a smart substation. The proposed SLBP is based on the IEC61850 standards and the concept consists of the acquisition of Generic Object Oriented Substation Event GOOSE used for tripping and interlocks exchange between Intelligent Equipment Devices IEDs and the reading of the Sampled Value SV existing in the process bus coming from Mergin Units MU or Non-Conventional Instrument Transformers NCIT. Several logical schemes to protect different zones of the substation are presented and how can be integrated using data in the substation automation system. The SLBP was developed using an open source library and free operating system. Moreover, a low cost prototype is presented in order to evaluate the efficiency and the operation of the SLBP under diverse scenarios of the proposed logical protective schemes such us breaker failure and overcurrent protection

Collaboration network of the authors

16 authors · 47 co-authorship links · 4 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Hassan II Casablanca
  • Cadi Ayyad University
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Faissal El MariamiUniversity of Hassan II Casablanca10
Elmahdi KhoudryUniversity of Hassan II Casablanca9
Tayeb OuaderhmanUniversity of Hassan II Casablanca8
Nazha CherkaouiAffiliation unknown6
Anass LekbichUniversity of Hassan II Casablanca5
Abdelmajid BerdaiUniversity of Hassan II Casablanca4
Chaimae ZedakUniversity of Hassan II Casablanca3
Ali TarraqUniversity of Hassan II Casablanca2
Touria HaidiUniversity of Hassan II Casablanca2
Naima AgouzoulUniversity of Hassan II Casablanca2
Aziz OukennouCadi Ayyad University2
Rabiaa GadalUniversity of Hassan II Casablanca2

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Smart Local Backup Protection for Smart Substation</dc:title><dc:creator>Dazahra, M.N.</dc:creator><dc:creator>Elmariami, F.</dc:creator><dc:creator>Belfqih, A.</dc:creator><dc:creator>Boukherouaa, J.</dc:creator><dc:description>&lt;jats:p&gt;This paper presents a novel smart local backup protection SLBP used for the support and backup of the protective relays in a smart substation. The proposed SLBP is based on the IEC61850 standards and the concept consists of the acquisition of Generic Object Oriented Substation Event GOOSE used for tripping and interlocks exchange between Intelligent Equipment Devices IEDs and the reading of the Sampled Value SV existing in the process bus coming from Mergin Units MU or Non-Conventional Instrument Transformers NCIT. Several logical schemes to protect different zones of the substation are presented and how can be integrated using data in the substation automation system. The SLBP was developed using an open source library and free operating system. Moreover, a low cost prototype is presented in order to evaluate the efficiency and the operation of the SLBP under diverse scenarios of the proposed logical protective schemes such us breaker failure and overcurrent protection&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i5.pp2321-2328</dc:identifier><dc:identifier>10.11591/ijece.v7i5.pp2321-2328</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 5 (2017); 2321</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8182/7608</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>