Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Study on the Effect of the Ambient Temperature toward the Quality of Sleep

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 6 (2017)

DOI
10.11591/ijece.v7i6.pp2986-2992
ISSN
2088-8708, 2088-8708
Terbit
2017-12-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

Getting enough sleep at the right times can help in improving quality of life and protect mental and physical health. This study proposes a portable sleep monitoring device to determine the relationship between the ambient temperature and quality of sleep. Body condition parameter such as heart rate, body temperature and body movement was used to determine quality of sleep. All readings will be log into database so that users can review back and hence analyze quality of sleep. The functionality of the overall system is designed for a better experience with a very minimal intervention to the user. The simple test on the body condition (body temperature and heart rate) while asleep with several different ambient temperatures are varied and the result shows that someone has a better sleep for the temperature range of 23 to 28 degree Celsius. This can prove by lower body temperature and lower heart rate.

Jaringan kolaborasi para penulis

23 penulis · 80 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • Universiti Teknologi MARA
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muhammad Noorazlan Shah ZainudinUniversiti Teknikal Malaysia Melaka4
Hyreil Anuar KasdirinUniversiti Teknikal Malaysia Melaka4
Syafeeza Ahmad RadziUniversiti Teknikal Malaysia Melaka2
Nursabilillah Mohd AliAfiliasi tidak diketahui2
Mohd Shahrieel Mohd ArasUniversiti Teknikal Malaysia Melaka2
Norafizah Binti AbasUniversiti Teknikal Malaysia Melaka2
Norafizah AbasUniversiti Teknikal Malaysia Melaka2
Nursabilillah Mohd AliUniversiti Teknikal Malaysia Melaka2
Zarina RazlanUniversiti Teknologi MARA2
Khairul Muzzammil SaipullahUniversiti Teknikal Malaysia Melaka1
Sook Hui ChongUniversiti Teknikal Malaysia Melaka1
Muhammad Idzdihar IdrisUniversiti Teknikal Malaysia Melaka1
Yan Chiew WongUniversiti Teknikal Malaysia Melaka1
A. H. Nurul HidayahUniversiti Teknikal Malaysia Melaka1
Norazlina Abdul RazakAfiliasi tidak diketahui1
A. Azureen NajaUniversiti Teknikal Malaysia Melaka1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Study on the Effect of the Ambient Temperature toward the Quality of Sleep</dc:title><dc:creator>Mohd Saad, Wira Hidayat bin</dc:creator><dc:creator>Wuen, Khoo Chin</dc:creator><dc:creator>Mat Ibrahim, Masrullizam bin</dc:creator><dc:creator>Mohd Saad, Nor Hashimah Binti</dc:creator><dc:creator>Ahmad Radz, Syafeeza Binti</dc:creator><dc:creator>Bin Mohamad Shokri, Ahmad Sayuthi</dc:creator><dc:creator>Karis, Mohd Safirin bin</dc:creator><dc:description>&lt;jats:p&gt;Getting enough sleep at the right times can help in improving quality of life and protect mental and physical health. This study proposes a portable sleep monitoring device to determine the relationship between the ambient temperature and quality of sleep. Body condition parameter such as heart rate, body temperature and body movement was used to determine quality of sleep. All readings will be log into database so that users can review back and hence analyze quality of sleep. The functionality of the overall system is designed for a better experience with a very minimal intervention to the user. The simple test on the body condition (body temperature and heart rate) while asleep with several different ambient temperatures are varied and the result shows that someone has a better sleep for the temperature range of 23 to 28 degree Celsius. This can prove by lower body temperature and lower heart rate.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i6.pp2986-2992</dc:identifier><dc:identifier>10.11591/ijece.v7i6.pp2986-2992</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 6 (2017); 2986</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8666/7262</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>