Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design and Development of a Shortwave near Infrared Spectroscopy using NIR LEDs and Regression Model

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 6 (2017)

DOI
10.11591/ijece.v7i6.pp3070-3075
ISSN
2088-8708, 2088-8708
Terbit
2017-12-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

Near infrared (NIR) spectroscopic technology has been getting more attention in various fields. The development of a low cost NIR spectroscopy is crucial to reduce the financial barriers so that more NIR spectroscopic applications will be investigated and developed by means of the NIR spectroscopic technology. This study proposes an alternative to measure shortwave NIR spectrum using one collimating lens, two slits, one NIR transmission grating, one linear array sensor, and one microcontroller. Five high precision narrow bands NIR light emitting diodes (LEDs) were used to calibrate the proposed spectroscopy. The effects of the proposed two slits design, the distance between the grating and linear array sensor, and three different regression models were investigated. The accuracy of the proposed design was cross-validated using leave-one-out cross-validation. Results show that the proposed two slits design was able to eliminate unwanted signals substantially, and the cross-validation was able to estimate the best model with root mean squared error of cross-validation of 3.8932nm. Findings indicate that the cross-validation approach is a good approach to estimate the final model without over-fitting, and the proposed shortwave NIR spectroscopy was able to estimate the peak value of the acquired spectrum from NIR LEDs with RMSE of 1.1616nm.

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Design and Development of a Shortwave near Infrared Spectroscopy using NIR LEDs and Regression Model</dc:title><dc:creator>Chia, Kim Seng</dc:creator><dc:creator>Tan, Yit Peng</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;span&amp;gt;Near infrared (NIR) spectroscopic technology has been getting more attention in various fields. The development of a low cost NIR spectroscopy is crucial to reduce the financial barriers so that more NIR spectroscopic applications will be investigated and developed by means of the NIR spectroscopic technology. This study proposes an alternative to measure shortwave NIR spectrum using one collimating lens, two slits, one NIR transmission grating, one linear array sensor, and one microcontroller. Five high precision narrow bands NIR light emitting diodes (LEDs) were used to calibrate the proposed spectroscopy. The effects of the proposed two slits design, the distance between the grating and linear array sensor, and three different regression models were investigated. The accuracy of the proposed design was cross-validated using leave-one-out cross-validation. Results show that the proposed two slits design was able to eliminate unwanted signals substantially, and the cross-validation was able to estimate the best model with root mean squared error of cross-validation of 3.8932nm. Findings indicate that the cross-validation approach is a good approach to estimate the final model without over-fitting, and the proposed shortwave NIR spectroscopy was able to estimate the peak value of the acquired spectrum from NIR LEDs with RMSE of 1.1616nm.&amp;lt;/span&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i6.pp3070-3075</dc:identifier><dc:identifier>10.11591/ijece.v7i6.pp3070-3075</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 6 (2017); 3070</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8676/7271</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>