Melola Discovery

← Melola Discovery

Open access Jurnal SINTA 1

Electric Filed Intensity of the Lightning Strikes on Lightning Air Terminals Installed on Building Structures

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 7 No. 6 (2017)

DOI
10.11591/ijece.v7i6.pp3105-3113
ISSN
2088-8708, 2088-8708
Published
2017-12-01
Publisher
Institute of Advanced Engineering and Science
License
creativecommons.org/licenses/by-nc/4.0

Abstract

Lightning activities are growing up rapidly with global warming. It can affect anything on the earth. All the constructed buildings need proper protection from the harmful effect of lightning. Lightning strike points on different geometrical shapes have been investigated. Lightning strike distribution of different building structure is very important to be studied. In order to analyse the maximum effect of lightning strike pattern is obtained of different air terminals installed on scaled building structures. High voltage impulse generator is used in order to get the impulse voltage. Different numbers of air terminals have been applied to all the shapes in order to see the lightning strike points. Electric field is obtained in order to see its minimum and maximum effect on the entire building structure. Interestingly the phenomenon of lightning air terminal bypasses has been proved in this paper.

Collaboration network of the authors

19 authors · 74 co-authorship links

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • Tun Hussein Onn University of Malaysia
  • Affiliation unknown
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
M. N. R. BaharomTun Hussein Onn University of Malaysia2
Habibu AhmadTun Hussein Onn University of Malaysia2
Nor Akmal Mohd JamailTun Hussein Onn University of Malaysia2
Rahisham Abd RahmanTun Hussein Onn University of Malaysia2
N.A.M. HasniTun Hussein Onn University of Malaysia1
Mohd Syahidie KamaruddinTun Hussein Onn University of Malaysia1
S.S. RidzwanTun Hussein Onn University of Malaysia1
M. S. KamarudinTun Hussein Onn University of Malaysia1
Nordiana Azlin OthmanTun Hussein Onn University of Malaysia1
Mohd Fairouz Mohd YousofTun Hussein Onn University of Malaysia1
Matiullah AhsanTun Hussein Onn University of Malaysia1
Md Nor Ramdon BaharomTun Hussein Onn University of Malaysia1
Omar Abu HassanTun Hussein Onn University of Malaysia1
Faridah HanimAffiliation unknown1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Electric Filed Intensity of the Lightning Strikes on Lightning Air Terminals Installed on Building Structures</dc:title><dc:creator>Ullah, Irshad</dc:creator><dc:creator>Baharom, MNR</dc:creator><dc:creator>Luqman, H.M.</dc:creator><dc:creator>Ahmad, H.</dc:creator><dc:creator>Zainal, Zainab</dc:creator><dc:description>&lt;jats:p&gt;Lightning activities are growing up rapidly with global warming. It can affect anything on the earth. All the constructed buildings need proper protection from the harmful effect of lightning. Lightning strike points on different geometrical shapes have been investigated. Lightning strike distribution of different building structure is very important to be studied. In order to analyse the maximum effect of lightning strike pattern is obtained of different air terminals installed on scaled building structures. High voltage impulse generator is used in order to get the impulse voltage. Different numbers of air terminals have been applied to all the shapes in order to see the lightning strike points. Electric field is obtained in order to see its minimum and maximum effect on the entire building structure. Interestingly the phenomenon of lightning air terminal bypasses has been proved in this paper.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2017-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v7i6.pp3105-3113</dc:identifier><dc:identifier>10.11591/ijece.v7i6.pp3105-3113</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 7 No 6 (2017); 3105</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/8680/7438</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>