Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Development of Virtual Resistance Meters using LabVIEW

International Journal of Electrical and Computer Engineering (IJECE) · Vol. 8 No. 1 (2018)

DOI
10.11591/ijece.v8i1.pp133-140
ISSN
2088-8708, 2088-8708
Terbit
2018-02-01
Penerbit
Institute of Advanced Engineering and Science
Lisensi
creativecommons.org/licenses/by-nc/4.0

Abstrak

This paper presents the development of three virtual resistance meters using LabVIEW. The unknown resistance is measured in terms of a known resistance of high accuracy by employing (a) a real dc voltage source, (b) a real dc current source, and (c) a virtual dc voltage source. In each case, ratio of two voltage signals is acquired by a single-ADC based multichannel data acquisition card. Therefore error of the ADC gets cancelled, when ratio of two voltages is used in the final calculation of the value of unknown resistance. The first two VRMs use a real excitation source and are thus semi-virtual instruments, whereas the third one is fully-virtual as the excitation source is also implemented in the LabVIEW software along with DAC section of the data acquisition card. The three virtual resistance meters have been successfully implemented. The principle of ratio-metric measurement used makes the accuracy (uncertainty) of final measurement free from the uncertainties of the ADC, the DAC and the excitation source. Standard deviations of the readings taken with the three VRMs have been evaluated and compared. It is concluded that the fully-virtual instrument has the lowest and excellent value of standard deviation.

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sharda University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Data ini berasal dari Crossref (yang disetorkan penerbit), karena endpoint OAI-PMH milik jurnal tidak dapat di-harvest.

Sumber metadata: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, pertama di-harvest 27 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata sebagai oai_dc, dikonversi dari Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Development of Virtual Resistance Meters using LabVIEW</dc:title><dc:creator>Lata, Suman</dc:creator><dc:creator>Verma, H. K.</dc:creator><dc:creator>Kumari, Puja</dc:creator><dc:description>&lt;jats:p&gt;This paper presents the development of three virtual resistance meters using LabVIEW. The unknown resistance is measured in terms of a known resistance of high accuracy by employing (a) a real dc voltage source, (b) a real dc current source, and (c) a virtual dc voltage source. In each case, ratio of two voltage signals is acquired by a single-ADC based multichannel data acquisition card. Therefore error of the ADC gets cancelled, when ratio of two voltages is used in the final calculation of the value of unknown resistance. The first two VRMs use a real excitation source and are thus semi-virtual instruments, whereas the third one is fully-virtual as the excitation source is also implemented in the LabVIEW software along with DAC section of the data acquisition card. The three virtual resistance meters have been successfully implemented. The principle of ratio-metric measurement used makes the accuracy (uncertainty) of final measurement free from the uncertainties of the ADC, the DAC and the excitation source. Standard deviations of the readings taken with the three VRMs have been evaluated and compared. It is concluded that the fully-virtual instrument has the lowest and excellent value of standard deviation.&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i1.pp133-140</dc:identifier><dc:identifier>10.11591/ijece.v8i1.pp133-140</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 1 (2018); 133</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/10107/8099</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>