Intelligent control included ANFIS and type-2 fuzzy (T2FLS) controllers grown-up rapidly and these controllers are applied successfully in power system control. Meanwhile, small signal stability problem appear in a large-scale power system (LSPS) due to load fluctuation. If this problem persists, and can not be solved, it will develop blackout on the LSPS. How to improve the LSPS stability due to load fluctuation is done in this research by coordinating of PSS based on ANFIS and T2FLS. The ANFIS parameters are obtained automatically by training process. Meanwhile, the T2FLS parameters are determined based on the knowledge that obtained from the ANFIS parameters. Input membership function (MF) of the ANFIS is 5 Gaussian MFs. On the other hand, input MF of the T2FLS is 3 Gaussian MFs. Results show that the T2FLS-PSS is able to maintain the stability by decreasing peak overshoot for rotor speed and angle. The T2FLS-PSS makes the settling time is shorter for rotor speed and angle on local mode oscillation as well as on inter-area oscillation than conventional/ ANFIS-PSS. Also, the T2FLS-PSS gives better performance than the other PSS when tested on single disturbance and multiple disturbances.

Collaboration network of the authors

12 authors · 31 co-authorship links · 11 across different organisations

Hover or tap a name to highlight its co-authors. Double-click to open the author's page.

  • University of Mataram
  • Malikussaleh University
  • Udayana University
  • Lampung University
  • Different organisations
  • Same organisation
  • Affiliation unknown
  • Thicker line = more joint articles · bigger circle = more articles
Show as table
Co-authorOrganisationJoint articles
Sultan SultanUniversity of Mataram3
Sabar NababanUniversity of Mataram3
Osea ZebuaLampung University3
Arnawan HasibuanMalikussaleh University1
Farhan AkbarMalikussaleh University1
Selamat MelialaMalikussaleh University1
Rosdiana RosdianaMalikussaleh University1
Raihan PutriMalikussaleh University1

Affiliations come from OpenAlex; journal OAI-PMH metadata carries none. Authors without an OpenAlex ID are matched by name, which can merge or split people.

This record comes from Crossref (what the publisher deposited), because the journal's own OAI-PMH endpoint could not be harvested.

Metadata source: Crossref API (cadangan, berdasarkan ISSN) https://api.crossref.org/journals/2088-8708/works, first harvested 27 Okt 2026, last seen 27 Okt 2026.
Metadata as oai_dc, converted from Crossref
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title>Coordination of Adaptive Neuro Fuzzy Inference System (ANFIS) and Type-2 Fuzzy Logic System-Power System Stabilizer (T2FLS-PSS) to Improve a Large-scale Power System Stability</dc:title><dc:creator>Muljono, Agung Budi</dc:creator><dc:creator>Ginarsa, I. M.</dc:creator><dc:creator>Nrartha, I. M. A.</dc:creator><dc:creator>Dharma, A.</dc:creator><dc:description>&lt;jats:p&gt;&amp;lt;p align="LEFT"&amp;gt;Intelligent control included ANFIS and type-2 fuzzy (T2FLS) controllers grown-up rapidly and these controllers are applied successfully in power system control. Meanwhile, small signal stability problem appear in a large-scale power system (LSPS) due to load fluctuation. If this problem persists, and can not be solved, it will develop blackout on the LSPS. How to improve the LSPS stability due to load fluctuation is done in this research by coordinating of PSS based on ANFIS and T2FLS. The ANFIS parameters are obtained automatically by training process. Meanwhile, the T2FLS parameters are determined based on the knowledge that obtained from the ANFIS parameters. Input membership function (MF) of the ANFIS is 5 Gaussian MFs. On the other hand, input MF of the T2FLS is 3 Gaussian MFs. Results show that the T2FLS-PSS is able to maintain the stability by decreasing peak overshoot for rotor speed and angle. The T2FLS-PSS makes the settling time is shorter for rotor speed and angle on local mode oscillation as well as on inter-area oscillation than conventional/ ANFIS-PSS. Also, the T2FLS-PSS gives better performance than the other PSS when tested on single disturbance and multiple disturbances.&amp;lt;/p&amp;gt;&lt;/jats:p&gt;</dc:description><dc:publisher>Institute of Advanced Engineering and Science</dc:publisher><dc:date>2018-02-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.11591/ijece.v8i1.pp76-86</dc:identifier><dc:identifier>10.11591/ijece.v8i1.pp76-86</dc:identifier><dc:source>International Journal of Electrical and Computer Engineering (IJECE); Vol 8 No 1 (2018); 76</dc:source><dc:source>2088-8708</dc:source><dc:source>2088-8708</dc:source><dc:relation>http://ijece.iaescore.com/index.php/IJECE/article/viewFile/10101/8093</dc:relation><dc:rights>http://creativecommons.org/licenses/by-nc/4.0</dc:rights></oai_dc:dc>